Jc670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment

China Jc670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment, Find details about China Hygienic Pressure Sensor, Flat-Diaphragm Pressure Sensor from Jc670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment

Model NO.
JC670
Range of Power Supply
12~36VDC
Signal Output
4~20mA / 1~5 V DC /0~5 V DC / 0.5~4.5V DC
Load Resistance
≤(U-12)/0.02Ω
Insulation Resistance
100mΩ,500VDC
Response Time
≤2 Ms
Weight
0.5kg
Trademark
jiucheng
Origin
Nanjing, China
Model NO.
JC670
Range of Power Supply
12~36VDC
Signal Output
4~20mA / 1~5 V DC /0~5 V DC / 0.5~4.5V DC
Load Resistance
≤(U-12)/0.02Ω
Insulation Resistance
100mΩ,500VDC
Response Time
≤2 Ms
Weight
0.5kg
Trademark
jiucheng
Origin
Nanjing, China
Jc670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment

JC670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment Overview:

JC670 hygienic flat-diaphragm pressure sensor for beverage equipment adopts imported high-accuracy and high-stability pressure sensor module to covert the absolute pressure or the gauge pressure of the measured medium into 4 ~ 20mA, 1 ~ 5V / 0 ~ 5V standard electrical signal through high-reliability amplification circuit and precise temperature compensation. High-quality sensor and encapsulation technology of full seal welding as well as improved assembling process have ensured excellent quality and best performance of this series of product. 

JC670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment Features:
* High stability and high sensitivity
* Lightning and RFI immunity
* Fully made of stainless steel
* Clean flat type isolating diaphragm
* Diversified signal output form and adjustable zero 
* Point and full scale
* Reverse polarity protection and transient over-current and over-voltage protection

Jc670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment

JC670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment Application:
* Hygienic pressure pipelines
* Food and beverage processing
* Medical and pharmaceutical
* Sewage treatment
* Viscous medium pressure measurement 


Jc670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment

Technical Parameters:
Measured MediumLiquid, gas or vapor compatible with 316 stainless steel
Measuring range-100KPa~0~ 20KPa…35MPa
Overload capacity1.5 times FS pressure
Pressure typeGauge pressure or absolute pressure
Overall accuracyTypical: ±0.25%FSMaximum: ±0.5%FS)
Long-term stabilityTypical: ±0.1%FS/ yearMaximum: ±0.2%FS/ year
Zero point temperature driftTypical: ±0.02%FS/ºC  Maximum: ±0.03%FS/ºC   
Sensitivity temperature driftTypical: ±0.02%FS/ºCMaximum: ±0.03%FS/ºC   
Medium temperature-20~85ºC
Compensation temperature-10 ~ 50ºC  
Ambient temperature-20~80ºC
Range of power supply12~36VDC (24VDC generally)
Signal output4~20mA / 1~5 V DC /0~5 V DC / 0.5~4.5V DC
Load resistance≤(U-12)/0.02Ω
Thermal lagging±0.1% (typical)
Process connectionM30x1.5 external thread or clamp
Enclosure protection degreePlug type (IP65); cable type (IP67)
Safe explosion-proof degreeEx iaII CT6
Response time≤2 ms
Insulation resistance100MΩ,500VDC
WeightApprox. 0.5kg  

Ordering Information:
JC670Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment
 Pressure typeGauge pressure ( G, may not be indicated); absolute pressure (A)
 RangeMeasuring Range( 0~ X  KPa or MPa)
 CodeOverall accuracy (linearity + repeatability + lagging)
1±0.5%FS 
2±0.25%FS 
3±0.1%FS 
 Code Signal Output
A14~20mA  
V11~5V DC  
V20~5V DC  
V30.5~4.5V DC
 CodeAdditional functions
F1M30x1.5 external thread
F2Clamp type
F0Special
W1Cable type (IP67, 2m)
W2Socket type (IP65, DIN43650)
E       ntrinsically safe explosion-proof type Ex iaIICT5
JC670(0~100KPa)  -1   -A1  -F1  -W1         Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment

Tips for Type Selection
* The measured medium shall be compatible with the material contacting with the product.
* The code E, an additional function code for selection, namely, intrinsically safe explosion-proof Ex iaIICT5, must be power supplied via safety barrier.
* Please contact us for other special requirements and clearly indicate them in the order.
* During the field installation of flat diaphragm, the correct sealing method shall be adopted to prevent the installation stress influencing product stability.

Jc670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment
Jc670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment

About Jiucheng
Jc670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment

Qualification and Certificate:
Jc670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment

Jc670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment


Product Packaging:
We choose cartons and protective pads that can be recycled. This will maximize the protection of our products from damage during transportation.
Jc670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment

Product Transportation:
We only choose the global express service providers. We will deliver the goods to you at the most efficient speed.
Jc670 Hygienic Flat-Diaphragm Pressure Sensor for Beverage Equipment