Jc670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor

China Jc670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor, Find details about China Flush Diaphragm Pressure Sensor, Diaphragm Pressure Sensor from Jc670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor

Model NO.
JC670
Range of Power Supply
12~36VDC
Signal Output
4~20mA / 1~5 V DC /0~5 V DC / 0.5~4.5V DC
Load Resistance
≤(U-12)/0.02Ω
Insulation Resistance
100mΩ,500VDC
Response Time
≤2 Ms
Weight
0.5kg
Trademark
jiucheng
Origin
Nanjing, China
Model NO.
JC670
Range of Power Supply
12~36VDC
Signal Output
4~20mA / 1~5 V DC /0~5 V DC / 0.5~4.5V DC
Load Resistance
≤(U-12)/0.02Ω
Insulation Resistance
100mΩ,500VDC
Response Time
≤2 Ms
Weight
0.5kg
Trademark
jiucheng
Origin
Nanjing, China
Jc670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor

JC670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor Overview:

JC670 fluid flat membrane flush diaphragm pressure sensor adopts imported high-accuracy and high-stability pressure sensor module to covert the absolute pressure or the gauge pressure of the measured medium into 4 ~ 20mA, 1 ~ 5V / 0 ~ 5V standard electrical signal through high-reliability amplification circuit and precise temperature compensation. High-quality sensor and encapsulation technology of full seal welding as well as improved assembling process have ensured excellent quality and best performance of this series of product. 

JC670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor Features:
* High stability and high sensitivity
* Lightning and RFI immunity
* Fully made of stainless steel
* Clean flat type isolating diaphragm
* Diversified signal output form and adjustable zero 
* Point and full scale
* Reverse polarity protection and transient over-current and over-voltage protection

Jc670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor

JC670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor Application:
* Hygienic pressure pipelines
* Food and beverage processing
* Medical and pharmaceutical
* Sewage treatment
* Viscous medium pressure measurement 


Jc670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor

Technical Parameters:
Measured MediumLiquid, gas or vapor compatible with 316 stainless steel
Measuring range-100KPa~0~ 20KPa…35MPa
Overload capacity1.5 times FS pressure
Pressure typeGauge pressure or absolute pressure
Overall accuracyTypical: ±0.25%FSMaximum: ±0.5%FS)
Long-term stabilityTypical: ±0.1%FS/ yearMaximum: ±0.2%FS/ year
Zero point temperature driftTypical: ±0.02%FS/ºC  Maximum: ±0.03%FS/ºC   
Sensitivity temperature driftTypical: ±0.02%FS/ºCMaximum: ±0.03%FS/ºC   
Medium temperature-20~85ºC
Compensation temperature-10 ~ 50ºC  
Ambient temperature-20~80ºC
Range of power supply12~36VDC (24VDC generally)
Signal output4~20mA / 1~5 V DC /0~5 V DC / 0.5~4.5V DC
Load resistance≤(U-12)/0.02Ω
Thermal lagging±0.1% (typical)
Process connectionM30x1.5 external thread or clamp
Enclosure protection degreePlug type (IP65); cable type (IP67)
Safe explosion-proof degreeEx iaII CT6
Response time≤2 ms
Insulation resistance100MΩ,500VDC
WeightApprox. 0.5kg  

Ordering Information:
JC670Fluid Flat Membrane Flush Diaphragm Pressure Sensor
 Pressure typeGauge pressure ( G, may not be indicated); absolute pressure (A)
 RangeMeasuring Range( 0~ X  KPa or MPa)
 CodeOverall accuracy (linearity + repeatability + lagging)
1±0.5%FS 
2±0.25%FS 
3±0.1%FS 
 Code Signal Output
A14~20mA  
V11~5V DC  
V20~5V DC  
V30.5~4.5V DC
 CodeAdditional functions
F1M30x1.5 external thread
F2Clamp type
F0Special
W1Cable type (IP67, 2m)
W2Socket type (IP65, DIN43650)
E       ntrinsically safe explosion-proof type Ex iaIICT5
JC670(0~100KPa)  -1   -A1  -F1  -W1       Fluid Flat Membrane Flush Diaphragm Pressure Sensor

Tips for Type Selection
* The measured medium shall be compatible with the material contacting with the product.
* The code E, an additional function code for selection, namely, intrinsically safe explosion-proof Ex iaIICT5, must be power supplied via safety barrier.
* Please contact us for other special requirements and clearly indicate them in the order.
* During the field installation of flat diaphragm, the correct sealing method shall be adopted to prevent the installation stress influencing product stability.

Jc670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor
Jc670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor

About Jiucheng
Jc670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor

Qualification and Certificate:
Jc670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor

Jc670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor


Product Packaging:
We choose cartons and protective pads that can be recycled. This will maximize the protection of our products from damage during transportation.
Jc670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor

Product Transportation:
We only choose the global express service providers. We will deliver the goods to you at the most efficient speed.
Jc670 Fluid Flat Membrane Flush Diaphragm Pressure Sensor