China Jc620 General-Purpose Pressure Sensor, Find details about China Pressure Sensor, General-Purpose Pressure Sensor from Jc620 General-Purpose Pressure Sensor
Measuring range | -100KPa~0~5KPa...100MPa | ||
Overload capacity | 2 times of FS pressure (1.1 times of FS pressure for 100MPa) | ||
Pressure type | Gauge pressure or absolute pressure | ||
Measuring Media | The gas or liquid compatible with 316 stainless steel | ||
Overall accuracy (Linearity, repeatability and hysteresis) | ±0.25%FS | ±0.4%FS | |
Long-term stability | Typical:±0.1%FS | Maximum:±0.2%FS | |
Zero temperature drift | Typical:±0.02%FS/ºC | Maximum:±0.05%FS/ºC | |
Sensitivity temperature drift | Typical:±0.02%FS/ºC | Maximum:0.05%FS/ºC | |
Operating temperature | -40~ 85ºC | ||
Compensation temperature | -10 ~60ºC | ||
Range of power supply | 12~36VDC(generally 24VDC) | ||
Signal output | 4~20mA / 1~5VDC / 0~5VDC / 0.5~4.5VDC | ||
Load resistance | ≤(U-12)/0.02 Ω | ||
Enclosure protection class | Plug type(IP65);cable type(IP67) | ||
Safety and explosion protection | Ex iaII CT5 | ||
Weight | About 0.5kg | ||
Vibration error | ≤±0.01%FS(Axles X, Y and Z,200Hz/g) | ||
Response time | ≤2 ms | ||
Resolution | Infinitely small(theoretic),1/100000(normal) | ||
Dielectric strength / RF degree | EN50081-1; EN50082-2;IEC61000-4-3 | ||
Pressure connection | See the product selection table and process connection diagram (customizable) | ||
Electrical connection | See the product selection table and electrical connection diagram (customizable) | ||
Interface and housing | Stainless steel 1Cr18Ni9Ti | ||
O-ring | Fluoro rubber | ||
Sensor diaphragm | Stainless steel 316L |
Plug | Cable | 4-20mA | 1-5V/0~5V/0.5-4.5V DC |
1 | Red | Positive power supply: +V | Positive power supply: +V |
2 | Blue | Signal output / negative power supply: OUT/-V | Positive signal output: +OUT |
3 | White | Idle | Common port / power source end: GND/-V |
4 (┴) | Yellow | Grounded in case of strong disturbance | Reliably grounded in case of strong disturbance |
JC620 | General-purpose Pressure Sensor | |||||
Code | Pressure type | |||||
G | Gauge pressure ( G may not be indicated ) | |||||
A | Absolute pressure | |||||
Range | Measuring range ( 0~ X KPa or MPa ) | |||||
Code | Overall accuracy (linearity + repeatability + hysteresis) | |||||
1 | ±0.4%FS | |||||
2 | ±0.25%FS | |||||
3 | ±0.1%FS | |||||
Code | Signal output | |||||
A1 | 4~20mA | |||||
V1 | 1~5V DC | |||||
V2 | 0~5V DC | |||||
V3 | 0.5~4.5V DC | |||||
Code | Additional functions | |||||
F1 | M20x1.5 external thread | |||||
F2 | G1/4 external thread | |||||
F3 | 1/4NPT external thread | |||||
F4 | 1/2-20 UNF-2A | |||||
F0 | Special | |||||
W1 | Cable type (See Outline Drawing I) | |||||
W2 | Socket type (See Outline Drawing II) | |||||
L1 | 31/2LCD display | |||||
L2 | 31/2LED display | |||||
P | Flush diaphragm type | |||||
E | Intrinsically safe explosion-proof type Ex iaIICT5 | |||||
JC620(0~100KPa)-1 -A1 -F1 -L2 General-purpose Pressure Sensor |