Jc630 Wind Differential Pressure Transducer

China Jc630 Wind Differential Pressure Transducer, Find details about China Pressure Transducer, Differential Pressure Transducer from Jc630 Wind Differential Pressure Transducer

Model NO.
Jc630
Sensitivity Temperature Coefficient
±0.02~±0.05%Fs/ºC
Response Time
≤1 Ms
Load Resistance
≤(U-12)/0.02 Ω
Range of Power Supply
12~36VDC
Vibration Error
≤±0.01%Fs
Signal Output
4~20mA / 1~5V DC
Trademark
jiucheng
Origin
Nanjing, China
Model NO.
Jc630
Sensitivity Temperature Coefficient
±0.02~±0.05%Fs/ºC
Response Time
≤1 Ms
Load Resistance
≤(U-12)/0.02 Ω
Range of Power Supply
12~36VDC
Vibration Error
≤±0.01%Fs
Signal Output
4~20mA / 1~5V DC
Trademark
jiucheng
Origin
Nanjing, China
Jc630 Wind Differential Pressure Transducer

Jc630 Wind Differential Pressure Transducer Overview:

Designed with high-quality components from a foreign company, Jc630 wind differential pressure transducer adopts the circuit of normalized design and assembly process as well as unique sensor stress isolation technology, to convert the differential pressure signal of the measured medium into 4~20mA or 1~5V DC standard signal through temperature compensation and high-stability amplification process. High-quality sensor, circuit of normalized design, superb encapsulation technology as well as improved assembling process ensure superior quality and best performance of this product. This series product is specially designed for industrial and civil OEM customers, for which new cost performance standard has been established.
Jc630 Wind Differential Pressure Transducer

Jc630 Wind Differential Pressure Transducer Features:
* High performance cost ratio
* From 0~0.5kpa to 0~700kpa
* Continuously adjustable zero point and range 
* Lightning and radio frequency immunity 
* Reverse polarity protection and current-limiting protection
* Compact structure, elegant appearance, and easy Installation 
* Normalized design and production guarantee stable quality and performance of the product
* The product can be designed or improved as per customers' specific requirements

Jc630 Wind Differential Pressure Transducer

Jc630 Wind Differential Pressure Transducer Application:
* Purification equipment and cleaning engineering
* Dust control and environmental protection
* Underground ventilation monitoring
* Hearth pressure or hearth negative pressure
* Measurement of air pressure and flow rate in industrial process
* Medial instruments and equipment
* Fan measurement and control
* HVAC
Jc630 Wind Differential Pressure Transducer

Technical Parameters:
Measuring rangeDifferential pressure / air pressure:0~500Pa…700KPa
Negative pressure:0~-500Pa…-1KPa…-5KPa…-10KPa….-50KPa…-100KPa
Permissible overpressureThree times of FS pressure
Measuring mediaNon-corrosive, dust-free dry gas
Overall accuracy (linearity + 
repeatability+ hysteresis)
±0.1%FS±0.25%FS±0.5%FS
Medium temperature-20ºC~85ºC 
Compensation temperature-10ºC~55ºC 
Ambient temperature-10ºC~80ºC
Zero temperature driftTypical:±0.02%FS/ºCMaximum:±0.05%FS/ºC
Sensitivity temperature driftTypical:±0.02%FS/ºCMaximum:±0.05%FS/ºC
Long-term stabilityTypical:±0.1%FS/yearMaximum:±0.2%FS/ year
Range of power supply12~36VDC(generally 24VDC)
Signal output4~20mA / 1~5V DC 
Load resistance≤(U-12)/0.02 Ω
Enclosure materialHard aluminum alloy surface coating or 304 stainless steel
Protection classIP65 or IP67
Process connectionφ8 tip, with M10×1 mounting screws (threaded connection can be made in special cases)
Ex-markExia II CT6(intrinsically safe explosion-proof type)
WeightApprox.0.35Kg 
Vibration error≤±0.01%FS(Axes X, Y and Z,200Hz/g)
Thermal hysteresis±0.1%FS(typical value)
Response time≤1 ms
Insulation resistance100MΩ,500V DC
ResolutionInfinitely small (theoretical),1/100000(normal)

Ordering Information:
JC630Wind Differential Pressure Transducer
 RangeMeasuring range( 0~ X  KPa)
 CodeOverall accuracy (linearity + repeatability+ hysteresis)
1±0.5%FS
2±0.25%FS
3±0.1%FS
 Code Signal output (standard power supply)
A14~20mA  
V11~5V DC  
V20~5V DC  
V30.5~4.5V DC
 CodeAdditional functions
F1M20x1.5
F2 G1/4 external thread
F3φ8 tip, with M10×1 mounting thread
F0Special
W1Cable type (IP67,2m)
W2Socket type (IP65,DIN43650)
W3 Aerial socket type(IP65)
E       Intrinsically safe explosion-proof type Ex iaПCT5
JC630 (0~500Pa)     -1    -A1  -F2  -W1      Wind Differential Pressure Transducer

Tips for Type Selection
* If the medium to be measured contains dusty or wet gas, be sure to select supporting dust-proof dry filters for connecting lines, and remove wet dust or make a replacement on time.
* As an additional function code for type selection, the code "E" for intrinsically safe explosion-proof type Ex iaIICT5 denotes that power source must be supplied via safety barrier.
* For other special requirements, please discuss with us and clearly indicate them in the order.

Jc630 Wind Differential Pressure Transducer

Jc630 Wind Differential Pressure Transducer

Jc630 Wind Differential Pressure Transducer
 

About Jiucheng

Jc630 Wind Differential Pressure Transducer

Qualification and Certificate:
Jc630 Wind Differential Pressure Transducer

Jc630 Wind Differential Pressure Transducer


Product Packaging:
We choose cartons and protective pads that can be recycled. This will maximize the protection of our products from damage during transportation.
Jc630 Wind Differential Pressure Transducer

Product Transportation:
We only choose the global express service providers. We will deliver the goods to you at the most efficient speed.
Jc630 Wind Differential Pressure Transducer