Lead Protection Room Annular Joint Flaw Detector and Lead Room

China Lead Protection Room Annular Joint Flaw Detector and Lead Room, Find details about China Non-Destructive Testing, X-ray from Lead Protection Room Annular Joint Flaw Detector and Lead Room

Model NO.
EN source
Model NO.
EN source
Basic Info:
 
Model NO.EN source
Product materialS30408, 06Cr19Ni10, SUS304, etc
Diameter rangeφ300mm~φ650mm
Length range800mm~2200mm
Single wall thickness range

 2.5mm~6mm (not including girth weld backing plate and necking)

Weight500Kg
After-sales Service3-Year Warranty
Inspection object welding defects on the ring and longitudinal weld on the LNG cylinder
The system resolutionnot less than 3.0LP/mm
The system dynamic range12bit.

·Note: all the machines of our company are customized. Please consult the salesman for specific parameters.

Lead Protection Room Annular Joint Flaw Detector and Lead Room


Product Description:

01 Annular joint flaw detector and lead room

Circumferential seam flaw detection and lead room are very important components of LNG cylinder production line.
Their role is to conduct nondestructive test on the tank.
The product can be damaged and protected through the production line composed of high-frequency X-ray flaw detector and lead protection room.

Lead Protection Room Annular Joint Flaw Detector and Lead Room



02 Annular joint flaw detector and lead room standards

·The Whole System:
 Annular joint flaw detector and lead room in line with GB/T 17925-2011 "X-ray digital imaging inspection of butt welds in gas cylinders.

·X-ray machine system:
 Annular joint flaw detector and lead room in line with JB/T 7412 "Fixed (mobile) industrial X-ray flaw detector.

·Image quality:
 Annular joint flaw detector and lead room 
1).JB/T 4730 "Non-destructive testing of pressure equipment.
2).JB/T 7902 "Non-destructive testing linear image quality meter.
3).JB/T 10815 "Non-destructive testing, radiographic image resolution tester
5).JB/T5453 "Technical Conditions of Industrial X-ray Image Intensifier TV System


·Lead protection room:
 Annular joint flaw detector and lead room Lead protection room: GBZ117-2006 "Radiation Health Protection Standard for Industrial X-ray Inspection.

Lead Protection Room Annular Joint Flaw Detector and Lead Room

The system is mainly composed of seven parts:
high-frequency X-ray flaw detector,
digital flat panel imaging system,
computer image processing system,
protection system,electrical control system,
mechanical system and field monitoring system.



Lead Protection Room Annular Joint Flaw Detector and Lead Room