China Tire Repair Tools Car Lift Tire Changer Garage Equipment for Tire Shop, Find details about China Tire Changer, Tyre Auto Tools from Tire Repair Tools Car Lift Tire Changer Garage Equipment for Tire Shop
YuanMech Product List | ||||||||||||||
Model | Working Truntable | Leverless Hook Device | Helper Arm | Bead Blaster Function | ||||||||||
Series | Model No. | 19" | 20" | 22" | 24" | Leverless | Left Helper Arm | Upper Double Cylinder Helper | Upper Single Left Helper | Upper Single Right Helper | Two Point Pressure | Three Point Pressure | IT | |
Swing Arm Type | MC951 | |||||||||||||
C952 | ||||||||||||||
C953 | C953 | 19" | ||||||||||||
C955 | C955 | 22" | ||||||||||||
C9551 | 22" | Left Helper Arm | ||||||||||||
C9552 | 22" | Upper Double Cylinder Helper | ||||||||||||
C9552L | 22" | Upper Single Left Helper | ||||||||||||
C9552R | 22" | Upper Single Right Helper | ||||||||||||
C956 | 24" | |||||||||||||
Tilt Back Arm Type | C957 | C957 | 22" | |||||||||||
C9572 | 22" | Two Point Pressure Right Helper | ||||||||||||
C9573 | 22" | Three Point Pressure Right Helper | ||||||||||||
C9572S | 22" | Leverless | Two Point Pressure Right Helper | |||||||||||
C9573S | 22" | Leverless | Three Point Pressure Right Helper | |||||||||||
C958 | C958 | 24" | ||||||||||||
C9582 | 24" | Two Point Pressure Right Helper | ||||||||||||
C9583 | 24" | Three Point Pressure Right Helper | ||||||||||||
C9582S | 24" | Leverless | Two Point Pressure Right Helper | |||||||||||
C9583S | 24" | Leverless | Three Point Pressure Right Helper |
1. Why is filter-regulator (FRL) so important?
It dry the air so there is no moisture inside pneumatic components. It lubricates the rubber seals to extend its service life. In general FRL is important to maintain long service life of the machine.
2. When working table doesn't turn, how to determine if the problem comes from gearbox, motor or switch?
Disconnect belt and see if the motor can run properly. If not, test the motor itself to see clockwise rotation and anti-clockwise rotation. If motor running properly then the problem is the switch.
We have trouble shooting in details, please contact us for more information.
3. When working table doesn't have needed power to clamp the rim, how to trouble shooting if the problem comes from table cylinder, turning air distributor or pedal valve?
When the cylinder not strong enough, there could be air leaking. The leaking could be on the covers or internal piston. There is a systematic method to trouble shoot, please contact us if you are interested in how to trouble shoot.