China Micro Hardness Tester Vickers (MHV-1000Z), Find details about China Hardness Tester Vickers, Universal Hardness Tester from Micro Hardness Tester Vickers (MHV-1000Z)
The Vickers hardness test method consists of indenting the test material with a diamond indenter, in the form of a right pyramid with a square base and an angle of 136 degrees between opposite faces subjected to a load of 1 to 100 kgf. The full load is normally applied for 10 to 15 seconds.
The two diagonals of the indentation left in the surface of the material after removal of the load are measured using a microscope and their average calculated. The area of the sloping surface of the indentation is calculated. The Vickers hardness is the quotient obtained by dividing the kgf load by the square mm area of indentation.
When selecting a hardness tester for your application, it is important for you to consider the following:
A, Choose the correct test method based on the application.
Plan to use the highest test force and largest indenter possible. Consider the effects of the shape and dimensions of your test sample.
B, Verify the test results meet your requirements for accuracy and repeatability. There are significant differences between levels of performance within each classification of tester. A difficult job on one tester could be very simple and fast on another.
Answer these key questions:
1, What kind of hardness scale to be used?
2, What is the material to be tested, and is this material suitable to the type of test method you are considering?
3, How large is the part, component or specimen to be tested?
4, Is the test point difficult to reach?
5, What is the quantity of testing that will be done?
6, How accurate does your test result need to be?
7, What is your budget?
8, What is the required return on investment and do you have ways to measure reductions in costs- yields, throughput, operator efficiency?
9, What testing problems have you experienced in your current method?
10, How knowledgeable are the users of the tester?
Verify the test results meet your requirements for accuracy and repeatability. There are significant differences between levels of performance within each classification of tester. A difficult job on one tester could be very simple and fast on another.
So, although hardness testers within a test method and classification look alike, there are many features that can significantly affect productivity and accuracy. A good example of features affecting performance is demonstrated in bench Rockwell hardness testing systems.
All can handle moderately long parts using larger anvils or jack rests, however the portable type can usually test large parts more quickly and accurately, when compared to other bench testers, which require external support stands or fixtures. The SHR150 series, on the other hand, is much easier to use on small, awkward parts.
Specifications: | |||
Product Name | Single-Indenter Digital Micro Vickers Hardness Tester | Double-Indenter Digital Micro Vickers Hardness Tester | |
Model | Vexus MHV-1000Z | Vexus MHV-1000ZK | |
Code# | 823-113 | 823-123 | |
Testing Force | gf | 10 \ 25 \ 50 \ 100 \ 200 \ 300 \ 500 \ 1000 | |
N | 0.098 \ 0.246 \ 0.49 \ 0.98 \ 1.96 \ 2.94 \ 4.90 \ 9.80 | ||
Indenter | HV Indenter | HV and HK Indenter | |
Lens & Indenter Switch | Auto-Turret | ||
Indentation Measurement | Digital Sensor Measurement | ||
Loading Control | Automatic (Loading, Dwell, Unloading) | ||
Magnification of Microscope | Observation:10x; Measurement:40x | ||
Digital Eyepiece | Magnification:10x | ||
Auto Hardness Conversion | HV \ HRC \ HB | ||
Hardness Indication | LCD display | ||
Dwell Time | Adjustable 1~99s | ||
Testing Range | 1HV~2967HV | ||
X-Y Anvil | Size:100x100mm; Travel:25 x25mm; Resolution:2um | ||
Illumination | Adjustable LED 6V, Cold light-source | ||
Display | D1 \ D2 \ HV/HRC/HB/HK \ Time | ||
Max. Height of Specimen | 70mm | ||
Instrument Throat | 95mm | ||
Power Supply | AC220V/50Hz;110V/60Hz | ||
Dimension(LxWxH) | 490 x250 x395mm | ||
Packing Dimension | 530 x450 x750mm | ||
Gross/Net Weight | 50Kg/40Kg | ||
Execution Standard | ISO 6507 , ASTM E92 , JIS Z2244 , GB/T4340 | ||
Standard Delivery: | |||
Standard Delivery | Code# | Standard Delivery | Code# |
Vickers Indenter | 823-403 | Objectives 40x/10x | 823-343/313 |
Knoop Indenter (MHV-1000ZK) | 823-413 | X-Y Anvil | 823-703 |
Vickers Hardness Block HV 0.5 | 823-623 | 10x Digital Eyepiece | 823-303 |
Vickers Hardness Block HV 1 | 823-613 | Power Cable | 823-803 |
Accessories Box | 823-903 | Level Screw | 823-933 |
Anti-dust Cover | 823-913 | Instrument Manual | Vexus MHV-1000Z |
Optional Accessories: | |||
Optional Accessories | Code# | Optional Accessories | Code# |
Vickers Measuring Software | 823-381 | Unequal Spencimen Clamp | 823-741 |
25mm Digital Micrometer Head | 823-719 | Filament Clamp | 823-761 |
Thin-piece Clamp | 823-751 | Flat Precision Clamp | 823-711 |
Knoop indenter | 823-411 | 15x Digital Eyepiece | 823-351 |
USB Camera USB-V1 | 823-473 |