Integrated Medical Operating Room Aseptic Industrial Chiller with Reliable Performance

China Integrated Medical Operating Room Aseptic Industrial Chiller with Reliable Performance, Find details about China Clean Type Air Conditioning, Air Conditioning from Integrated Medical Operating Room Aseptic Industrial Chiller with Reliable Performance

Model NO.
ACU-3B
Noise Level
Ordinary
Application Fields
The Hospital
Mounting
Floor Standing
Lifetime
>20 years
Certification
CCC
Condition
New
Compressor Brand
Copeland/Daikin/Panasonic/Hitachi
Refrigerant
R22
Refrigerating Capacity
7500W-25000W
The Heating
3990W-11990W
Fan
The Original German Import Ebm Centrifugal Fan
Machine Custom
According to The Demand for Custom-Made
Trademark
HI-SURP
Transport Package
Fully Enclosed Export Packing
Specification
Non-Standard Custom
Origin
China
HS Code
8415
Model NO.
ACU-3B
Noise Level
Ordinary
Application Fields
The Hospital
Mounting
Floor Standing
Lifetime
>20 years
Certification
CCC
Condition
New
Compressor Brand
Copeland/Daikin/Panasonic/Hitachi
Refrigerant
R22
Refrigerating Capacity
7500W-25000W
The Heating
3990W-11990W
Fan
The Original German Import Ebm Centrifugal Fan
Machine Custom
According to The Demand for Custom-Made
Trademark
HI-SURP
Transport Package
Fully Enclosed Export Packing
Specification
Non-Standard Custom
Origin
China
HS Code
8415

Features:

Intelligent control of temperature and humidity, free combination to meet cleanliness requirements.
By adjusting the number of ACU (Air Condition Unit and FFU (Fan Fiter Unit) settings, the free combination design can clean the air from 10,000 to 10,000 cleanliness.
Adding purification and stratification can also achieve class 100 air cleanliness, which meets different air cleanliness requirements from general surgery to transplant surgery. Indoor temperature and humidity sensors are used to automatically and intelligently adjust the room
Temperature and humidity, meet the constant temperature and humidity requirements you set. The intelligent control system equipped with ACU can control the operation of the system equipment under the requirements you set.
No special air-conditioning room and equipment floor are needed, making full use of effective space.
The air filtering and cleaning necessary for the sterile room, constant heating and cooling, humidification, dehumidification and other functions are adjusted and controlled by an independent ACU. The unit does not need to set up aseptic air-conditioning room and equipment floor.
In addition, the required air lines are less, so the system is not limited by the size of the space and can be freely combined and set. Operating room, the air-conditioning unit with all the internal equipment is embedded in the wall and the wall is integrated into one body.
By adding air-conditioning equipment rooms and equipment floors like other air-conditioning purification systems, the saved space becomes a disinfection room, so that your valuable space can be fully and effectively used.
Independent system, high efficiency and energy saving, low operating cost.
In the case of multiple operating room settings, each operating room system can operate independently. You can set the operating room environment separately according to the needs of the operation. Each system is equipped with a single high-efficiency space
The adjustment avoids energy waste of large-scale central air-conditioning equipment and reduces operating costs.
Quickly achieve the predetermined cleanliness.
0.3μm 0.0.P test results, 99.99% filtration efficiency, 1500 m3 / h air volume, and the change curve of cleanliness in the operating room after the system starts. You can see the
Fast, 10,000 grade cleanliness can be achieved in just 5 minutes, and high cleanliness of 1,000 grades can be achieved in 12.5 minutes. Therefore, it is possible to quickly provide the necessary clean space in an emergency.
Low noise (42dB) and low vibration.
The air conditioner unit test results achieved a low noise level of 42 dB, and the actual measurement result of a clean room equipped with two air conditioner class 1,000 cleanliness was only 45 dB. Low noise and low vibration design
To fully realize.
Easy installation and short construction period.

Due to the dry and wet construction method, the main components are assembled in the factory and moved to the construction site. Therefore, it has the characteristics of low installation noise, fast construction and less garbage. With 2 6m
High ceiling rooms can be fitted with medical air conditioning systems. This system has the advantages of easy moving in, simple installation and short construction period.
It is the best way to transform existing wards and operating rooms.
Because it will not affect the normal work of medical staff and the existing air conditioning system, this system is the best way to convert an existing ward or operating room into a sterile room.
Refrigeration range

Cooling capacity from 7.5kW-12kW, whether it is retrofitting or rebuilding,
Air-conditioning machine room, so the freedom of choosing the setting place is large, saving your valuable space,
Can be widely used in hospital operating rooms, waiting rooms, nursing staff offices, rest rooms, etc.
Place to solve the problem of clean air.
Integrated Medical Operating Room Aseptic Industrial Chiller with Reliable PerformanceIntegrated Medical Operating Room Aseptic Industrial Chiller with Reliable PerformanceIntegrated Medical Operating Room Aseptic Industrial Chiller with Reliable PerformanceIntegrated Medical Operating Room Aseptic Industrial Chiller with Reliable PerformanceIntegrated Medical Operating Room Aseptic Industrial Chiller with Reliable PerformanceIntegrated Medical Operating Room Aseptic Industrial Chiller with Reliable PerformanceIntegrated Medical Operating Room Aseptic Industrial Chiller with Reliable PerformanceIntegrated Medical Operating Room Aseptic Industrial Chiller with Reliable PerformanceIntegrated Medical Operating Room Aseptic Industrial Chiller with Reliable Performance