China 20 Ton Air Cooled Floor Standing Duct Split Air Conditioner, Find details about China Central Air Conditioner Split, 20 Ton Floor Standing Air Conditioner from 20 Ton Air Cooled Floor Standing Duct Split Air Conditioner
Model | HAD03(H) | HAD05(H) | HAD06(H) | HAD08(H) | HAD10(H) | HAD12(H) | HAD15(H) | HAD18(H) | HAD20(H) | HAD25(H) | HAD30(H) | HAD36(H) | HAD40(H) | HAD50(H) | HAD60(H) | |||
Unit performance | Cooling capacity | kw | 7.8 | 13 | 15.6 | 20.8 | 26 | 31.2 | 39 | 46.8 | 52 | 65 | 78 | 93.6 | 104 | 130 | 156 | |
Heating capacity | kw | 8.1 | 13.6 | 16.5 | 22.1 | 27.5 | 33 | 41.5 | 50.2 | 56.8 | 69 | 82 | 98 | 110 | 136 | 162 | ||
*Electric heating | kw | 3 | 4 | 5 | 6 | 8 | 9 | 12 | 15 | 16 | 18 | 25 | 30 | 32 | 36 | 50 | ||
Air flow | m3/h | 1700 | 2600 | 3100 | 4100 | 5400 | 6500 | 8000 | 9600 | 10800 | 13800 | 16000 | 19500 | 20500 | 25500 | 27000 | ||
External static pressure | Pa | 80 | 100 | 110 | 110 | 120 | 180 | 200 | 200 | 220 | 230 | 230 | 260 | 300 | 340 | 350 | ||
Power Supply | 220V | 380V/3N~50Hz | ||||||||||||||||
Refrigerant | Type | R22/R407C | ||||||||||||||||
Volume control | expansion valve/capillary tube | |||||||||||||||||
Charge | kg | 3.5 | 5 | 5 | 5+3.5 | 5*2 | 5.6*2 | 5*3 | 5.6*3 | 5*4 | 5.6*4 | 10*2+5 | 10*3 | 10*2+5 | 10*4 | 10*5 | ||
Compressor | Type | flexible hermetic scroll compressor | ||||||||||||||||
Power | kw | 2.25 | 3.75 | 4.5 | 3.75+2.25 | 3.75*2 | 4.5*2 | 3.75*3 | 4.5*3 | 3.75*4 | 4.5*4 | 9*2+3.75 | 9*3 | 9*3+3.75 | 9*4 | 9*5 | ||
Evaporator | Type | copper tube with aluminium fin | ||||||||||||||||
Fin type | Slotted-type two-way aluminum fin/honeycomb type aluminum fin | |||||||||||||||||
Indoor unit | Fan | Type | centrifugal type | |||||||||||||||
Driving method | direct-drive | belt-drive | ||||||||||||||||
Power | kw | 0.25 | 0.55 | 0.55 | 0.28*2 | 0.55*2 | 1.5 | 2.2 | 2.2 | 3 | 3 | 4 | 5.5 | 5.5 | 7.5 | 11 | ||
Unit Dimension | L | mm | 800 | 1000 | 1100 | 1250 | 1250 | 1450 | 1650 | 1720 | 1800 | 1800 | 2000 | 2100 | 2200 | 2400 | 2550 | |
W | mm | 500 | 500 | 500 | 600 | 600 | 800 | 800 | 800 | 800 | 900 | 900 | 1000 | 1000 | 1300 | 1500 | ||
H | mm | 1400 | 1500 | 1500 | 1600 | 1600 | 1700 | 1800 | 1950 | 1950 | 2000 | 2000 | 2200 | 2200 | 2250 | 2400 | ||
Weight | kg | 70 | 90 | 100 | 140 | 160 | 225 | 280 | 320 | 350 | 440 | 480 | 580 | 630 | 700 | 815 | ||
Noise level | dB/(A) | <50 | <52 | <52 | <52 | <56 | <60 | <65 | <65 | <67 | <67 | <67 | <67 | <68 | <70 | <72 | ||
Outdoor unit | Compressor | Type | Hermetic Scroll | |||||||||||||||
Power | kw | 2.25 | 3.75 | 4.5 | 3.75+2.25 | 3.75*2 | 4.5*2 | 3.75*3 | 4.5*3 | 3.75*4 | 4.5*4 | 9*2+3.75 | 9*3 | 9*3+3.75 | 9*4 | 9*5 | ||
Condenser | Type | tube with fin | ||||||||||||||||
Fin type | Slotted-type two-way aluminum fin | |||||||||||||||||
Blower | Type | ultra-low noise axial type | ||||||||||||||||
Driving method | direct-drive | |||||||||||||||||
Power | kw | 0.18 | 0.25 | 0.25 | 0.55 | 0.71 | 0.75 | 1.1 | 0.71*2 | 0.71*2 | 0.75*2 | 1.1*2 | 1.5*2 | 0.75*3 | 1.1*3 | 1.1*4 | ||
Unit Dimension | L | mm | 860 | 970 | 840 | 940 | 1050 | 1350 | 1350 | 1850 | 1950 | 2400 | 2450 | 2300 | 2800 | 3000 | 3000 | |
W | mm | 300 | 350 | 840 | 940 | 1050 | 1050 | 1200 | 1050 | 1050 | 1050 | 1100 | 1100 | 1100 | 1100 | 1100 | ||
H | mm | 830 | 1250 | 950 | 1250 | 1300 | 1300 | 1300 | 1150 | 1150 | 1250 | 1400 | 1400 | 1500 | 1500 | 1600 | ||
Weight | kg | 100 | 130 | 140 | 210 | 240 | 360 | 380 | 450 | 480 | 650 | 750 | 860 | 920 | 1360 | 1450 | ||
Noise level | dB(A) | 62 | 63 | 63 | 67 | 68 | 69 | 70 | 71 | 71 | 72 | 74 | 75 | 76 | 77 | 78 | ||
Connecting tubes | Refrigerant gas tube | Size | 15.9 | 19.1 | 19.1 | 19.1+ 15.9 | 19.1 | 19.1 | 19.1 | 19.1 | 19.1 | 19.1 | 28×2 +19.1 | 28 | 28×3+19.1 | 28 | 28 | |
Quantity | 1 | 1 | 1 | 1 | 2 | 2 | 3 | 3 | 4 | 4 | 1 | 3 | 1 | 4 | 5 | |||
Refrigerant liquid tube | Size | 9.52 | 12.7 | 12.7 | 12.7+ 9.52 | 12.7 | 12.7 | 12.7 | 12.7 | 12.7 | 12.7 | 15.9× 2+12.7 | 15.9 | 15.9×3+12.7 | 15.9 | 15.9 | ||
Quantity | 1 | 1 | 1 | 1 | 2 | 2 | 3 | 3 | 4 | 4 | 1 | 3 | 1 | 4 | 5 | |||
Connection method | flare opening | welding+flare opening |
No | Project Name ( China) | Industry | Area |
1 | Zhongshan people hospital | Hospital | Zhongshan |
2 | Hankou Railway Station, Union Hospital, Wuhan Branch | Hospital | Wuhan |
3 | Wuhan City, Wuchang Railway Hospital | Hospital | Wuhan |
4 | Three townships Zhongshan People's Hospital | Hospital | Zhongshan |
5 | Zhujiang hospital of Guangzhou | Hospital | Guangzhou |
6 | Zhongshan Garden Hotel | Hotel industry | Zhongshan |
7 | Western Sunshine Hotel, Zhongshan | Hotel industry | Zhongshan |
8 | Shunde Golden Hotel | Hotel industry | Foshan |
9 | East China Hotel in Guangzhou | Hotel industry | Guangzhou |
10 | Nanyou Zhuhai hotel | Hotel industry | Zhuhai |
No | Company Name ( Overseas) | Product | Country |
1 | SB Global Energy | Air cooled ducted split | Holland |
2 | Bentos pharmaceutical products Ltd. | Clean air conditioners | Nigeria |
3 | SOGAMEF | Air cooled chiller | Gabon |
4 | SeaService shipping | Marine air conditioner | Russia |
5 | EURO STANDARD LIMITED | Fresh Air Handling Unit | New Zealand |
6 | Henrich trading center | Air cooled/water cooled air conditioner | Philippines |
7 | Marine Engineering Systems Pte.Ltd | AHU, chiller,etc | Singapore |
8 | Elektro Werner Heitzinger | Heat recovery air handling unit | Austria |
9 | Nyborg Marine Equipments AS | Marine Air Handling Units | Norway |
10 | Wilfred Limited | Heat recovery air handling unit | UK |