Internal Thread Self-Standing Sterile 2.0ml Cryovials with Multi Codes with Side Barcode

China Internal Thread Self-Standing Sterile 2.0ml Cryovials with Multi Codes with Side Barcode, Find details about China Cryogenic Vials, Sterile Cryogenic Vials from Internal Thread Self-Standing Sterile 2.0ml Cryovials with Multi Codes with Side Barcode

Model NO.
88-621X
Temperature Resistance
-196 to 121
Side Barcode
Yes
Writing Area
Yes
Pces Per Case
1000
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
3917220000
Model NO.
88-621X
Temperature Resistance
-196 to 121
Side Barcode
Yes
Writing Area
Yes
Pces Per Case
1000
Trademark
BIOLOGIX
Origin
Changzhou City, Jiangsu Province, China
HS Code
3917220000
Internal Thread Self-Standing Sterile 2.0ml Cryovials with Multi Codes With Side Barcode
 
Internal Thread Self-Standing Sterile 2.0ml Cryovials with Multi Codes with Side Barcode
Internal Thread Self-Standing Sterile 2.0ml Cryovials with Multi Codes with Side Barcode
Internal Thread Self-Standing Sterile 2.0ml Cryovials with Multi Codes with Side Barcode


Features:
  1. Made of medical grade polypropylene; can be repeatedly frozen and thawed
  2. 2.0ml cryogenic vials are available with either internal or external screw threads
  3. Internal thread vials' caps are with o-rings, which will promote more secure sealing
  4. DNase & RNase free, endotoxin free, foreign DNA free
  5. With side barcode and digital code by Side laser printing, easy for information storage
  6. Working temperature: stable from -196°C to 121°C
  7. Suitable for liquid nitrogen freezing
Internal Thread Self-Standing Sterile 2.0ml Cryovials with Multi Codes with Side Barcode1. What are the main factors that influence the maximum centrifugal acceleration force?
Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

2.  What are autoclaving guidelines of plastics?
To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

3.  What are Biologix's Commitments to Quality?
We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.