Buried Underground Distribution Transformer 315kVA 11kv 0.4kv

China Buried Underground Distribution Transformer 315kVA 11kv 0.4kv, Find details about China Underground Transformer, Buried Transformer from Buried Underground Distribution Transformer 315kVA 11kv 0.4kv

Model NO.
S11-MD
Usage
Distribution Transformer
Frequency Characteristics
High Frequency
Shape of Core
Ring
Brand
Ville
Trademark
VILLE
Transport Package
Wooden Case or as Per Requirement
Specification
IEC CE, ISO
Origin
Ningbo China
HS Code
8504231100
Model NO.
S11-MD
Usage
Distribution Transformer
Frequency Characteristics
High Frequency
Shape of Core
Ring
Brand
Ville
Trademark
VILLE
Transport Package
Wooden Case or as Per Requirement
Specification
IEC CE, ISO
Origin
Ningbo China
HS Code
8504231100
Buried Distribution Transformer

Features:
S11-MD-underground distribution transformer core cold-rolled silicon steel miter joints using low-loss step-stack from the system. High and
low voltage coil using cylindrical and spiral wound structure. Transformer low voltage side of the watertight box structure using high-pressure
side of the head with waterproof cable products with anti-pollution, water and strong, no-load current, low noise, low loss, low temperature
characteristics, the product can be charged continuously run for a certain time soaking advantages. Advanced technical indicators,unique
structure, exquisite appearance, is particularly suitable for a water environment such as underground tunnels of a high-tech,
high-performance energy-saving products.

The transformers can be buried underground in pits ,and can meet the needs of single ring high -voltage power supply,applies to long
distances but small loading system ,such as roads ,bridges,and tunnels.
 
Transformer Standard:

GB  1094.3-2003( IEC 60076-3-2000) 
 
Service Condition:
1) Altitude: ≤1, 000m
2) Maximal ambient temperature: +40.C
3) Maximal daily average temperature: +30.C
4) Maximal annual average temperature: +20.C
5) Minimal ambient temperature: -25.C
6) Indoor or outdoor 

Technical parameters:
Tech data of 10kV SZ11 series on-load regulation distribution transformer
Rated capacity
(KVA)
Voltage group
(kV)
Vector groupImpedance voltage
(%)
Loss(kW)No-load current 
(%)
Weight(kg)Outline dimension (mm)Gauge vertical/
Horizontal
No-lossLoadBodyOilTotal
200(HV)   
6-15kV (LV) 
0.415-6kV
Yyno Dyn1140.343.061.554027011101400*740*1190550/550
2500.43.61.464029012701420*790*1210660/660
3150.484.321.473032015001540*850*1240660/660
4000.575.221.394037017801590*940*1250660/660
5000.686.211.3104037019201650*1000*1350660/660
6304.50.817.651.1122046022801810*1140*1350820/820
8000.969.361150050027401890*1200*1310820/820
10001.1510.981161052030601910*1260*1570820/820
12501.3613.050.9188070037101960*1280*1740820/820
16001.6415.570.8229078043502330*1800*1910820/820
20001.9621.260.8256090049502580*1900*1950820/820
25002.3124.690.73170101060202580*1940*22501070/1070
Note:it can supply voltage regulating range of ±4*2.5%for HV on load regulation transformers
Buried Underground Distribution Transformer 315kVA 11kv 0.4kv
Our Services
1.Pre sale service
a.make technical solution
b.send quotation, technical data sheet and drawing
c.prepare power transmission plan, testing plan and shipment plan
2.In sale service
a.supervise the manufacturing schedule totally in accordance with the plan
b.send photos to customer during every manufacturing process(hold point)
c.inform the customer one week before testing.
3.After sale service
a.installation and commissioning, training the workers
b.quick response within 12 hours any time
c.provide 12 months guarantee period normally.

FAQ 
Buried Underground Distribution Transformer 315kVA 11kv 0.4kv


Thanks for choosing VILLE as your reliable partner and please trust both
of us will create a brilliant future!