Pediatric Infant Neonate Children CPAP Neonate /Infant Bubble CPAP

China Pediatric Infant Neonate Children CPAP Neonate/Infant Bubble CPAP, Find details about China Ncpap, CPAP from Pediatric Infant Neonate Children CPAP Neonate/Infant Bubble CPAP

Model NO.
CHH-AD3 series
Trademark
iClear
Origin
China
HS Code
9019200000
Model NO.
CHH-AD3 series
Trademark
iClear
Origin
China
HS Code
9019200000

Pediatric Infant Neonate Children CPAP Neonate/Infant Bubble CPAP

Neonate/Infant Bubble CPAP
CHH-AD1P


Bubble CPAP is a sort of special medical equipment for supporting of babies' breath which devised and manufactured based on the wide application of closed continuous NCPAP in department of pediatrics. It uses on the course of ventilation treatment of Nasal-CPAP for premature, neonate, infant to children below 14 year old. The mode of CPAP can reduce babies' WOB effectively, while keeping the autonomous respiration well.

Superiority:
Supply a safe and controllable FIO2;
Keep the FRC effectively;
Reduce infant's WOB;
Reduce the need of invasive mechanical ventilation;
Supply better warm and humid gas;
Reduce the occurrence rate of the CLD;
Improve the physical sighs, such as height, weight.
 
Matching solution of Medical Air Compressor:
Max exhausting pressure: 0.7MPa
Output pressure: 0.20MPa~0.30MPa
Flow: >25L/ruin
Noise: <52dB(A)
 
Performance parameter:
FIO2: 21%~100%
Flow: 0~18LPM
CPAP pressure: 0.3~1.0kPa(3~10cmH2O)
Water capacity of Generator: 500ml or more
Alarm:the differential pressure> 0.1MPa, sound alarm
 
Common parameter:
Pressure of oxygen and air: 0.3MPa~0.4MPa
Power: 220V AC 50Hz
Certification: ISO 13485 CE
 
Parts:
Matching with Medical Electric Respiratory humidifier(PN-2000F/FA)
Working temperature: 30ºC~37ºC
Max temperature of heating plate: 85ºC
Capacity of Chamber:280ml(F-Adult); 230ml(FA-Infant)
Max flow: 180L/min
Max working pressure: 2kPa
 
CPAP Generator:
1. It is easy to set the oscillating gas pressure from 3cmH2O to 10cmH2O through adjusting the CPAP pressure bar.
2. The automatic regulating mechanism of water-level ensure the constant CPAP pressure.
3. The dismountable chamber is very convenient.


Pediatric Infant NCPAP
CHZ-AD2P

Bubble CPAP is a sort of special medical equipment for supporting of babies' breath which devised and manufactured based on the wide application of closed continuous NCPAP in department of pediatrics. It uses on the course of ventilation treatment of Nasal-CPAP for premature, neonate, infant to children below 14 year old. The mode of CPAP can reduce babies' work of breathing effectively, while keeping the autonomous respiration.
 
1.Assemble the main machine, humidifier and the optional compressor together, to save space.
2.Inside the Air-oxygen Blender, and the FIO2 is continuous and controllable.
3.Adjusting the oxygen concentration and the flow respectively.
4.It is easy to monitor the FIO2, to ensure the safety of oxygen.
5.High accuracy of CPAP regulating, combine the system pressure monitor with safety valve to ensure the safety of patient.
6.The main machine does not need electric power, and match with support arm.
7.The optional compressor adopts imported pump, with little water and low noise.
8.Match with humidifier that controlled by electric or automatically, to ensure the best situation of humidifier.
9.The light and diversified tubes and rhinobyons reduce the patient's WOB; the convenient fixed device reduces the
compressor of patient's head and face, and the injure of nasal septum.
10.It is applied to PIIUC, NICU, PICU and first aid room widely.
 
Technical parameter:
Ventilation mode: CPAP mode
FIO2: 21%~100%
Flow: 0~18LPM
CPAP adjustment: 0~1.0kPa(0~10cmH2O)
 
Monitor:
Pressure monitor: 0~2.5kPa(0~25kPa)
FIO2: 21%~100%
Pressure safety valve: if the pressure in tubes over 1.5 times than adjusting parameter, the safety valve will open automatically.
 
Alarm:
Differential alarm: differential pressure between 0.05MPa~0.12MPa, sound alarm.
Low battery alarm: when the voltage reduce to 6.8±V0.5V,LCD will alarm "LOW BATTERY".
 
Common parameter:
Size: W*H*D 24.7cm*17.5cm*21cm
Weight: about 6KG
Gas-source: 0.3MPa~0.4MPa


Pediatric Infant Neonate Children Type NCPAP
CHZ-AD3P

Advanced treatment reduces the unnecessary of tracheal cannula;
Reduce the time of mechanical ventilation effectively;
Avoid over-weaning;
Double blender output, can supply to two patients at the same time; expand to oxygen therapy, resuscitation, and BUBBLE CPAP;
MCV mode, save rescue time
Applied to infant with light respiratory failure infant but with high autonomous respiration too.
The mode of CPAP can reduce babies' WOB effectively, while keeping the autonomous respiration well.

Technical parameter:
CPAP mode: supply the constant flow and pressure confinement for neonate, premature continuously.
FIO2(Blender): 21%~100%
Flow: 0~18LPM
CPAP adjustment: 0~1.0kPa(0~10cmH2O)
MCV mode: button replace the artificial air ventilation
 
Alarm:
Differential alarm: differential pressure between 0.05MPa~0.12MPa, sound alarm.
Low battery alarm: when the voltage reduce to 6.8V±0.5V, LCD will alarm "LOW BATTERY"
 
Monitor:
Pressure monitor: 0~1kPa(0.10cmH2O)
FIO2: 21%~100%
Pressure safety valve: if the pressure in tubes over 1.5times than adjusting parameter, the safety valve will open automatically.
 
Common parameter:
Size: W*H*D 617.5cm*437.5cm*525cm
Weight: about 4KG
Gas-source: 0.3MPa~0.4MPa

Pediatric Infant Neonate Children CPAP Neonate/Infant Bubble CPAP
Pediatric Infant Neonate Children CPAP Neonate/Infant Bubble CPAP
Pediatric Infant Neonate Children CPAP Neonate/Infant Bubble CPAP
Pediatric Infant Neonate Children CPAP Neonate/Infant Bubble CPAP
Pediatric Infant Neonate Children CPAP Neonate/Infant Bubble CPAP
Pediatric Infant Neonate Children CPAP Neonate/Infant Bubble CPAP
Pediatric Infant Neonate Children CPAP Neonate/Infant Bubble CPAP
Pediatric Infant Neonate Children CPAP Neonate/Infant Bubble CPAP


Pediatric Infant Neonate Children CPAP Neonate/Infant Bubble CPAPPediatric Infant Neonate Children CPAP Neonate/Infant Bubble CPAP