Neonatal Medical Device Neonate Bilirubin Phototherapy Infant Incubator

China Neonatal Medical Device Neonate Bilirubin Phototherapy Infant Incubator, Find details about China Infant Incubator, Neonatal Incubator from Neonatal Medical Device Neonate Bilirubin Phototherapy Infant Incubator

Model NO.
CNME010711plus
Optional Configuration
">37 °c" Override Mode
Operating Range
20°c -30°c
Air Temperature Control Range
25°c-37°c
Temperature Uniformity
≤0.8°c
Failure Alarm
Over Temperature Alarm, Deviation Alarm
Trademark
CNMEDITECH
Specification
Dimension: 1085mm*640mm*1075mm
Origin
China(Mainland)
HS Code
9018909911
Model NO.
CNME010711plus
Optional Configuration
">37 °c" Override Mode
Operating Range
20°c -30°c
Air Temperature Control Range
25°c-37°c
Temperature Uniformity
≤0.8°c
Failure Alarm
Over Temperature Alarm, Deviation Alarm
Trademark
CNMEDITECH
Specification
Dimension: 1085mm*640mm*1075mm
Origin
China(Mainland)
HS Code
9018909911
Neonatal Medical Device Neonate Bilirubin Phototherapy Infant Incubator 
Neonatal Medical Device Neonate Bilirubin Phototherapy Infant Incubator
Brief Introduction:

Air mode control, set temperature and air temperature are displayed separately;
Passive humidification;
Multiple failure alarm indications;
RS-232 connector for data output;
CNME010711plus is configured with fixed Neonate Bilirubin Phototherapy Equipment with blue fluorescence lamp.

Standard Configuration:
Based on CNME010711, plus the Neonate Bilirubin Phototherapy Equipment with Blue Light Fluorescent Tubes(Fixed model).

Optional Configuration:
">37 °C" override mode is optional, Baby mode, Disposable skin temperature sensor, SpO2, Neonate Bilirubin Phototherapy Equipment with Blue LED (Fixed model)

Environmental temperature:
Operating range: 20°C -30°C(Set temperature should be 3°C higher than the environment temperature)
Ambient air velocity: < 0.3m/s

Specification:
Product name Neonatal Medical Device Neonate Bilirubin Phototherapy Infant Incubator
Power requirementAC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA
Control ModeAir mode control by micro-computer
Air temperature control range 25°C-37°C(Override mode: 37°C-39°C is optional)
The temperature fluctuation range between incubator temperature and average incubator temperature (Under stable temperature condition)≤0.5°C
Temperature Uniformity≤0.8°C
Noise inside hood≤45dB(A)
Failure alarmover temperature alarm, deviation alarm,
sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on.

Neonatal Medical Device Neonate Bilirubin Phototherapy Infant Incubator Product Packaging:
Packing: The whole unit is packed into one carton
Dimension: 1085mm x 640mm x 1075mm
Gross Weight: 83Kg

Neonatal Medical Device Neonate Bilirubin Phototherapy Infant IncubatorNeonatal Medical Device Neonate Bilirubin Phototherapy Infant IncubatorNeonatal Medical Device Neonate Bilirubin Phototherapy Infant IncubatorNeonatal Medical Device Neonate Bilirubin Phototherapy Infant Incubator