Medical Equipment Neonate Baby Care Infant Incubator

China Medical Equipment Neonate Baby Care Infant Incubator, Find details about China Newborn Incubator, Radiant Warmer from Medical Equipment Neonate Baby Care Infant Incubator

Model NO.
B-010 Standard
Gw
100kg
Control Mode
Air Mode
Environment Temperature
20 ~30
Temperature Fluctuation
+-0.5
Package Dimension
126*71*85cm
Trademark
BENEMED
Transport Package
Wooden Box
Specification
Infant incubator
Origin
China
HS Code
9018909000
Model NO.
B-010 Standard
Gw
100kg
Control Mode
Air Mode
Environment Temperature
20 ~30
Temperature Fluctuation
+-0.5
Package Dimension
126*71*85cm
Trademark
BENEMED
Transport Package
Wooden Box
Specification
Infant incubator
Origin
China
HS Code
9018909000

B-010 Standard Hospital Use Baby/Infant Incubator
Medical Equipment Neonate Baby Care Infant Incubator

Features:

1.Microprocessor based servo controlled temperature system
2.Air temperature,skin temperature,humidity,timer and heat power separately displayed by LED
3.Alarms functions : Power failure; over temperature; temperature deviation; temperature sensor failure;fan failure
4.Silence/reset button for alarms
5.Integral timer to record therapy time
6.Humidity is adjustable continuously
7.>37°C temperature setting
8.A keypad lock  prevent inadvertent changes the setting
9.Trough for pulling and pushing ,which is convenient to add water and wash 
10.Fan with low noise and long life-span
11.Temperature deviation and over temperature could be amended in front panel directly
12.A second thermal cut-off function for more safety
13.Skin temperature sensor failure protect function avoid over temperature
14.The infant bed inclination angle is adjustable
15.six operating windows,two sides operating windows can be swiveled
16.Heater is electrically cut-out if air temperature inside incubator exceed 40°C
17.big storage cabinet

 

Standard configuration

Main body(including the transparent hood,control system,infant bed,water trough),

skin temperature sensor,I.V.pole, mattress, height adjustable ;cabinet, castors

 

Optional parts:

Phototherapy up side unit
Phototherapy from up and down sides
RS232(485) connector
Tray/pole


Technical data:

Power supplyAC 110/220V  60/50Hz
Power input≤420VA
Operating conditions

Environment temperature: 20°C~30°C

Environment relative humidity: 30%~75%RH

Environment air velocity of flow: <0.3m/s

Air Temperature control range25°C~38°C
Skin temperature control range32°C~38.5°C
Skin temperature sensor accuracy+/-0.3°C
Temperature fluctuation+0.5°C
Uniformity of mattress temperature≤0.8°C
Warm-up time≤45min
Internal noise level≤55dB
Humidity display range10%-95%RH
Humidity accuracy≤10%RH
Infant bed tilt angle+10º
Mattress size67cm(L)×54cm(W)
Trough capacity1200ml
Air filter0.5um

  

Transport and storage

Each unit is packed in two wooden crate
Size (control unit and cabinet): 
120X 70X 96CM 
N. W.: 80KG G. W.: 110KG
Hood: 97X 56X 63CM 
N. W.: 15KG G. W.: 40KG 

Environment Temp-10°C--+70°C
Environment Relative Humidity≤80% RH
Atmospheric Pressure500~1060Hpa

Medical Equipment Neonate Baby Care Infant Incubator
Medical Equipment Neonate Baby Care Infant Incubator
Medical Equipment Neonate Baby Care Infant Incubator