Hbjh20 Infant Neonate Handhold Transcutaneous Jaundice Detector

China Hbjh20 Infant Neonate Handhold Transcutaneous Jaundice Detector, Find details about China Jaundice Detector, Transcutaneous Jaundice Detector from Hbjh20 Infant Neonate Handhold Transcutaneous Jaundice Detector

Model NO.
HBJH20-1A/HBJH20-1B/HBJH20-1C
Indication
Two-Figure LED Digital Display
Test Deviation
00~20±1 21~40±2
Average Counting
No
Light Resource
Xenon-Flashing Light
Power Supply
Nickel Xenon Battery No.5 of 4pieces
Charger
Input 220V 50Hz Output 6V 0.3ADC
Product Weight
About 340g
Product Size
171mm*74mm*41mm
Gross Weight
30kg
Trademark
WANROOEMED
Transport Package
Export Package
Specification
171mm*74mm*41mm
Origin
Jiangsu, China (Mainland)
HS Code
94029000
Model NO.
HBJH20-1A/HBJH20-1B/HBJH20-1C
Indication
Two-Figure LED Digital Display
Test Deviation
00~20±1 21~40±2
Average Counting
No
Light Resource
Xenon-Flashing Light
Power Supply
Nickel Xenon Battery No.5 of 4pieces
Charger
Input 220V 50Hz Output 6V 0.3ADC
Product Weight
About 340g
Product Size
171mm*74mm*41mm
Gross Weight
30kg
Trademark
WANROOEMED
Transport Package
Export Package
Specification
171mm*74mm*41mm
Origin
Jiangsu, China (Mainland)
HS Code
94029000
HBJH20 Infant Neonate Handhold Transcutaneous Jaundice Detector 
Hbjh20 Infant Neonate Handhold Transcutaneous Jaundice Detector

Technical Specification:
ModelHBJH20-1AHBJA20-1BHBJA20-1C
Checking methodsCompare the blue and green lightCompare the blue and green lightCompare the blue and green light
IndicationTwo-figure LED digital displayThree-figure LED digital display (one decimal digits)Three-figure LCD digital display (one decimal digits)
ReadableSwitch the measured value into the bilirubin value according to the comparative table
 
Test the bilirubin value directly on the forehead of babyTest the bilirubin value directly on the forehead of baby
Average countingNoNoCan calculate the measured average values for 2-5 times automatically
Test deviation00~20±1
21~40±2
0~15±1
16~25±1.5
0~15±1
16~25±1.5
Light resourceXenon-flashing lightXenon-flashing lightXenon-flashing light
Power supplyNickel xenon battery No.5 of 4piecesNickel xenon battery group 4.8VNickel xenon battery group 4.8V
Prepare time of start-up<10s<10s<5s
ChargerInput 220V 50Hz Output 6V 0.3ADCInput 220V 50Hz Output 6V 0.3ADCInput 220V 50Hz Output 6V 0.3ADC
CheckoutWhite screen indicates 00 or 01 Yellow screen indicates 20.0±1White screen indicates 00 or 01 Yellow screen indicates 20.0±1White screen indicates 00 or 01 Yellow screen indicates 20.0±1
Product WeightAbout 340gAbout 245gAbout 190g
Product siz171mm*74mm*41mm163mm*66mm*37mm161mm*53mm*30mm
Gross weight30kg
Packing dimension30cm*25cm*15cm