Atomic Absorption Spectrophotometer for Metal Analysis

China Atomic Absorption Spectrophotometer for Metal Analysis, Find details about China Atomic Absorption Spectrophotometer, Aas Spectrophotometer from Atomic Absorption Spectrophotometer for Metal Analysis

Model NO.
AA320N
Wavelengths
Double Beam
Dispersive Element
Grating Spectrometer
Light Number
No
Certification
ISO9001, CE
Customized
Customized
Working Spectral Range
190-900nm
Wavelength Accuracy
0.5nm
Wavelength Repeatability
0.3nm (Single Direction)
Spectrum Bandwidth
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Resolution
<40%
Base Line Stability
0.004ABS/30min
Characteristic Concentration of Copper
0.04mg/Ml/1%
Detection Limit of Copper
0.008mg/Ml
Background Calibration Ability
Greater Than 30 Times
Standby Interface
RS 232
Trademark
Nanbei
Transport Package
Wooden Case
Specification
CE, ISO 9001, ISO 14001 confirmed
Origin
Zhengzhou, Henan
HS Code
9027300000
Model NO.
AA320N
Wavelengths
Double Beam
Dispersive Element
Grating Spectrometer
Light Number
No
Certification
ISO9001, CE
Customized
Customized
Working Spectral Range
190-900nm
Wavelength Accuracy
0.5nm
Wavelength Repeatability
0.3nm (Single Direction)
Spectrum Bandwidth
0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Resolution
<40%
Base Line Stability
0.004ABS/30min
Characteristic Concentration of Copper
0.04mg/Ml/1%
Detection Limit of Copper
0.008mg/Ml
Background Calibration Ability
Greater Than 30 Times
Standby Interface
RS 232
Trademark
Nanbei
Transport Package
Wooden Case
Specification
CE, ISO 9001, ISO 14001 confirmed
Origin
Zhengzhou, Henan
HS Code
9027300000
Flame atomic absorption spectrophotometer for metal analysis

Characteristics A
1.Buildin computer data processing and LCD:Adopting highly integrated micro digital circuit, which is stable and reliable with the functions of integral holding, peak height and area, auto zeroadjusting, deuterium lamp and background, multilinear and nonlinear curves fitting, various parameters and working curves displayed in screen and report printing, etc. It is equipped with interface for externally linking PC.
2.Good basic line stability: Doublebeam system of optimized design can automatically compensate the light source drift and wavelength drift caused by the variation of temperature (with the function of the eliminating the affection of wavelength drift on the base line stability) and electronic circuit drift so as to reach a good basic line stability. 
3.The cathode lamp needs not be preheated for long time and sample can be analyzed immediately. It ithe preferable instrument chosen by users to conduct analysis of multiple kinds of elements and fast analysis of samples.
4.High precision of measurement: Gas path system is equipped with precision pressure stabilizing and current 
5.Stabilizing devices to reach stable flame and low noise. Specially designed fine light beam passes through the flame to ensure a high precision analytical test and low characteristic concentration
6.Longlife and anticorrosive atomization system: The burner is made of new type titanium alloys, anticorrosive and fast thermal equilibrium. It meets the requirement of measurement sensitivity without water-cooling.
7.Multifunctional analysis mode: For methods of flame absorption, flame emission, graphite furnace atomic absorption and hydride generation.
8.Safe and reliable gas path system: Special devices of quick gas conversion and safety protection can be used toanalyze air-acetylene flame .
9.Complete set of accessories: To be supplied with the instrument and ready for use after they are purchased.
Atomic Absorption Spectrophotometer for Metal Analysis
Characteristics B
1.Lightsource system: Hollow cathode lamp power supply: with adjustable current Deuterium Lamppower supply:with fixed current
2.Optical system: Double beam total refection system, CT type monochromator Flashing wavelength: 250nm
3.Flame atomization system: Interchangeable titanium alloy burner of 10cm and 5cm slits. Gas path is equipped with pressure indication, high precision voltage stabilizing flow adjustment, fast conversion of air and nitrous oxide, gas supply cut off, power cut off, prevention of flashback and logic interlock protection devices.
4.Signal processing: Absorptance, concentration, emission and emission concentration; Standard curves: linear regression, curve fitting and multipoint standard calibration. Average value, standard deviation, relative standard deviation and correlation coefficient can be worked out. Standard curves, atomic absorption peak diagram, spectrum outline sketch, data as well as instrument parameters list and analytical reports can be displayed and printed out.

Accessory
Main accessories supplied with the instrument: Several decades of accessories including air compressor, one piece of Cu hollow cathode lamp. Gas external pipe, acetylene cylinder pressure-reducing valve and water knockout gas filter.
Atomic Absorption Spectrophotometer for Metal Analysis
Atomic Absorption Spectrophotometer for Metal Analysis


Optional accessories
1.GA3202 HGA graphite furnace system: Used to conduct trace and ultratrace analysis with an absolute sensitivity of 10-10-10-12 gram.
2.5cm long-life titanium burner: The necessary accessory for nitrous oxide-acetylene flame analysis.
3.Hydride generator (Totally automatic): Making the characteristic concentration of As, Se, Sb, Bi, Pb, Sn, Te, Ge, In, Tl,Cd and Zn lower than ppb level with cold atomic mercury measurement method.
4.Hollow cathode lamp: All specifications are available.
5.Graphite tube: All specifications are available.
6.Software with I/O port
7.Printer


Technical Data
Technical data 
Working spectral range190-900nm
Wavelength accuracy≤ ±0.5nm
Wavelength repeatability≤ 0.3nm (single direction)
Spectrum bandwidth 0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Resolution<40%
Base line stability±0.004Abs/30min
Characteristic concentration of copper≤ 0.04mg/ml/1%
Detection limit of copper≤0.008mg/ml
Background calibration abilityGreater than 30 times
Standby InterfaceRS 232
Instrument power supply220V, 3A, 50Hz

Packing image
Atomic Absorption Spectrophotometer for Metal Analysis


 

FAQ     

1. How can I choose the suitable one?
Dear customer, please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.
2. Does your price is competitive?
Dear customer, we make sure to offer you the best quality with competitive price.
3. How can I pay?
Dear customer, we accept many payment term, such as T/T, Western Union…
4. When I receive it after pay?
Dear customer, normal models can be delivered with 5-7days, please contact us to check transport time to your address.
5. How to deliver?
Dear customer, we can send by Express, by Sea and by Air.
6. Is will be broken during transport?
Dear customer, please do not worry, we do standard export package.
7. What should I do if I do not know how to use?
Dear customer, please do not worry, manual user will be sent together, you can also contact us with more technological support.
8. What should I do if some parts broken?
Dear customer, please do not worry, we have 12months warranty except  wear parts. You can also buy parts from us after 12months.

Company Show:
Atomic Absorption Spectrophotometer for Metal Analysis


Factory Show:

Professional laboratory instrument manufacturer with 11 years of experience.
Export experience has been 8 years.
Shipping : 5days by courier,door to door service

Atomic Absorption Spectrophotometer for Metal Analysis

Certification:

The company has passed various international authoritative certifications such as SGS, CE, ISO.
Atomic Absorption Spectrophotometer for Metal Analysis

Warranty And After-sale Service

♥♥We Supply 1 Year Warranty , And Lifelong Free Technical Guiding And Training♥♥

Atomic Absorption Spectrophotometer for Metal Analysis