Biobase China Flame Absorption Method Atomic Absorption Spectrophotometer

Biobase China Flame Absorption Method Atomic Absorption Spectrophotometer, Find details about China Laboratory Atomic Absorption Spectrophotometer, Price of Spectrophotometer from Biobase China Flame Absorption Method Atomic Absorption Spectrophotometer

Model NO.
BK-AA4530F
Dispersive Element
Interferometer Spectrometer
Light Number
Monochromator
Customized
Non-Customized
Sensitivity
0.01ppm
Wavelength Range
190~900nm
Spectral Bandwidth
0.1, 0.2, 0.4, 1.0 and 2.0nm
Wavelength Accuracy
0.15nm
Grating
1800 Lines/mm
Inflamer
All-Metal Titanium Burner
Atomizer
Efficient Glass Atomizer
Lamp Stand
8
Packing Size(mm)
) 850*700*750(Main Instrument) 950*620*1020(Acce
Gross Weight(Kg)
105kg (Main Instrument) 100kg ( Accessories )
Optional
Graphite Furnace 4510GF
Trademark
BIOBASE
Transport Package
Wooden Box
Specification
950*620*1020
Origin
China
Model NO.
BK-AA4530F
Dispersive Element
Interferometer Spectrometer
Light Number
Monochromator
Customized
Non-Customized
Sensitivity
0.01ppm
Wavelength Range
190~900nm
Spectral Bandwidth
0.1, 0.2, 0.4, 1.0 and 2.0nm
Wavelength Accuracy
0.15nm
Grating
1800 Lines/mm
Inflamer
All-Metal Titanium Burner
Atomizer
Efficient Glass Atomizer
Lamp Stand
8
Packing Size(mm)
) 850*700*750(Main Instrument) 950*620*1020(Acce
Gross Weight(Kg)
105kg (Main Instrument) 100kg ( Accessories )
Optional
Graphite Furnace 4510GF
Trademark
BIOBASE
Transport Package
Wooden Box
Specification
950*620*1020
Origin
China
Product Description
 

BK-AA4530F Atomic Absorption Spectrophotometer

 
Biobase China Flame Absorption Method Atomic Absorption Spectrophotometer

Features:

* Completely controlled by PC, can flexibly select the flame and graphite furnace atomizer (optional).

* Integrated floated optical platform design improves the optical system shock resistance stable. 

* Eight light stands can be changed automatically and preheat the eight lights meantime as well as optimize the working condition of the hollow cathode lamp.

* Position adjusting: the flame burner can be set on the best position automatically.

* Fully automated wavelength scanning and peak searching.

* Complete safety chains protection equipment: warning and automatic safety protection for the wrong burner connection, leakage of the gas, under voltage of air and the abnormal flameout.

* Deuterium lamp and self-absorption background calibration.

* Measuring method: flame absorption method and emission method.

* Result printing: parameter, data result and diagram.

* Data processing: more than 500 data self-storage and cut-off storage, the analyzed result is stored in EXCEL format.

 

Product Parameters

Model

BK-AA4530F

Wavelength Range

190~900nm

Spectral Bandwidth

0.1, 0.2, 0.4, 1.0 and 2.0nm

Wavelength Accuracy

≤±0.15nm

Wavelength Receptivity

≤0.04nm

Base Line Stability

≤0.002A/30min (Cu)

Characteristic Concentration

0.02μg/ml/1% (Cu)

Detection Limit

0.004μg/ml (Cu)

Measurement Repeatability

≤0.5%

Grating

1800 lines/mm

Inflamer

All-metal titanium burner

Atomizer

Efficient glass atomizer

Lamp stand

8

D2 background Calibration

When the background is 1 A, the background ability should be deducted not less than 50 times; self absorption background deduction method

Power Supply

220V, 50/60Hz

Packing Size(mm)

850*700*750(Main instrument)

950*620*1020(Accessories )

Gross Weight(kg)

105Kg (Main instrument)

100Kg ( Accessories )

Standard Accessories

PC workstation

HP inkjet printer

Oil free Air compressor

Acetylene reducing valve

Cu Hollow cathode lamp

Air filter

Optional Accessories

Graphite Furnace 4510GF

Hollow cathode lamp(Ag, Au, Ca, Cd, Cr ,Fe, Hg ,K, AU, Mg,Mn, Na, Ni, Pb, Zn, Sb,etc)

Company Profile

Biobase China Flame Absorption Method Atomic Absorption Spectrophotometer

Our Main Products

Biobase China Flame Absorption Method Atomic Absorption Spectrophotometer

FAQ

1.Why choose BIOBASE?
We are the leading manufactuer in lab furniture and lab equipment, OEM & ODM service are offered. And we have our own overseas techinican and installation team.
2. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
3. When can I get the price?
We usually quote as soon as we get your inquiry. If you need urgent reply, please tell us your email or Skype account, we will contact you ASAP.
4. What can you buy from us?
Laboratory Equipment (Biological Safety Cabinet,Fume Hood,Laminar Flow Cabinet,Autoclave,Freezer and Refrigerator)
5. Why should you buy from us not from other suppliers?
BIOBASE group, founded in 1999 and been through high and stable development for 15 years, who is now with revenues of one hundred million, 1200 employees in China and abroad offices, 22.4 acres land industry parks and 20000 square meters production base.

Exhibition&Service

Biobase China Flame Absorption Method Atomic Absorption Spectrophotometer

Packaging & Shipping

Biobase China Flame Absorption Method Atomic Absorption Spectrophotometer

Contact Bailie