Natural Gas Generator From China Manufacturer, Find details about China Supplier Gas Generator, Natural Gas Generator from Natural Gas Generator From China Manufacturer
Engine of CUMMINS EG400 Natural Gas Generator Set | |
Engine Model | CUMMINS KT19 |
Type | 6 cylinders in line |
Bore * Stroke (mm) | 159*159 |
Displacement(L) | KT19 |
Compression ratio | 9.5:1 |
Rated speed(rpm) | 1500/1800 |
Inlet type | Exhaust Turbocharger/Air-Air Intercooler |
Cooling type | Cooling water tank |
Fuel System | Low and high pressure |
ESC Type | Special for U.S. GAC natural gas |
Ignition sequence | 1-5-3-6-2-4 |
The allowed maximum speed (Natural gas supply closed at this time) | 2160 rpm |
The allowed maximum rotating speed (The ignition system shut down at this time) | 2160 rpm |
Oil Capacity | 50 L |
Cooling water capacity | 132 L |
Maximum engine back pressure | 10.2 kpa |
Gas consumption(m3kw·h) | <0.3 |
Rough oil consumption(g/kWh) | <1.6 |
Radiator and oil cooler heat | 134KW |
Exhaust pipe heat radiation | 152KW |
Engine thermal radiation | 20KW |
Alternator thermal radiation | 8KW |
Cooling water temperature | 95 Deg C |
Oil temperature | <120 Deg C |
Exhaust pipe heat energy (above 120 º C section) | 380KW |
Exhaust temperature (before vortex ) | 670±15 Deg C |
Exhaust Flow | 3350 m³/h |
Fan exhaust flow | 14 m³/s |
Noise level from 1 m | less than 100 db(A) |
Alternator of CUMMINS EG400 Natural Gas Generator Set | |
Alternator Model | Engga EG315L-400N |
Excitation Method | Brushless Permanent Magnet |
Winding pitch | 2/3 pitch |
Number of poles | 4 |
Bearing number | 1 |
Stator Windings | 12 ends |
Insulation Class | H class |
Protection class | IP 21 or IP 23 |
Load type | Continuous operation |
AVR Model | WT-2 |
Alignment | Fly wheel |
Temperature Range | Less than 125 degrees Celsius |
Overload Capacity- the percentage of rated power | 110% |
Waveform distortion rate, no-load | <5% |
Voltage Regulation Mode | AVR |
Voltage Regulation Range | ±5% |
Steady State Voltage Regulation | ±1% |
No-load line voltage sine wave distortion | <2% |
Telephone interference factor (TIF) | < 50 |
CUMMINS EG400 Natural Gas Generator Set | |
Rated Output(KW) | 400 |
Standby Output(KW) | 440 |
Voltage(V) | 400 |
Current(A) | 720 |
Size(mm) | 3440*1300*1950 |
Approximate weight(KG) | 4000 |
Emission levels (Nox) | Euro II emission(mg/m³) |
Naturally aspirated engine intake air temperature | Not more than 45 Deg C |
Air temperature before entering the air to air intercooler | 82- 87(Deg C) |
Air temperature after entering the air to air intercooler | 35-42(Deg C) |
Rated Power @ 0.8 power factor (w / pump s and w / o fan) | 400KW (continuous operation) |
Total energy input (100% load) | 1105(KW) |
Electrical efficiency | 36.20% |
Thermal efficiency | 87.90% |
Control panel(Deepsea or others) | Synchronizing Control, Multilingual Mode Digital Control, Diagnostic Function, Direct Text Indicate of Faults, MOBUS Communication Protocol, Compatible Communication, Exchange Telecommunications, Wired Control Data Output, Automatic or manual start |