Handheld Bluetooth Medical ICU Patient Monitor with Six-Parameter Function

China Handheld Bluetooth Medical ICU Patient Monitor with Six-Parameter Function, Find details about China Veterinary Patient Monitor, Blood Pressure Monitor from Handheld Bluetooth Medical ICU Patient Monitor with Six-Parameter Function

Model NO.
UN2000B
Display
Color TFT Touch Screen
Touch Screen
Optional
Color
Blue
Battery
Rechargeable
IBP
Optional
Recharge Time
10 Hours.
Input
5- Lead ECG Cable
Measuring Range
0-150mmhg
Trademark
OEM
Transport Package
Carton
Specification
209mm× 104mm× 47.5mm
Origin
Shenzhen, China
HS Code
9018909000
Model NO.
UN2000B
Display
Color TFT Touch Screen
Touch Screen
Optional
Color
Blue
Battery
Rechargeable
IBP
Optional
Recharge Time
10 Hours.
Input
5- Lead ECG Cable
Measuring Range
0-150mmhg
Trademark
OEM
Transport Package
Carton
Specification
209mm× 104mm× 47.5mm
Origin
Shenzhen, China
HS Code
9018909000
  China Supplier 6 Parameters Hospital ICU Medical Patient Monitor Price 
UN2000B

Handheld Bluetooth Medical ICU Patient Monitor with Six-Parameter Function

Five parameters:ECG,NIBP,SPO2,PR,TEMP.
Waveform:ECG and SPO2 waveforms.


Features:
  • Touch screen,5.0 inch color TFT-LCD, simple for operating, quickly&accurately measure the data;
  • Build-in rechargeable Li-battery, up to 15 hours running time, support AC and DC power;
  • Adjustable audible and visual alarms, and sensor off alarm;
  • Long time monitoring and sleeping monitoring;
  • Easy to carry, suitable for ambulance center, has the stand for fixing;
  • ETCO2, FiCO2 and RR are optional.
Prior:
  • Storage and review data up to 3888groups via Trend Graph and Trend List.
  • USB and Bluetooth data upload;
  • Big font screen interface is easy to observe;
  • Back light can be adjusted;
  • Free advanced software are all standard on free(Bluetooth software; VSDV software for download the storage data; Guardian software for transmitting the real-time data and storage all data and waveform; Healthaids software for Android mobile)
  • Optional Bluetooth printer to print the waveform and data out.

Specification:
1. General Specifications:
Size: 209mm×104mm×47.5mm
Net Weight: 655g
Display Specification
Measurement Display: color TFT- LCD/touch screen
Power Supply Indicator: Dual-color LED (red/green)
Charging indicator: A green LED

2. Power Supply
AC Power Adaptor
Input: 100~240VAC, 50/60Hz, 0.7A
Output: DC 5V, 1.5A
Battery
Li-ion rechargeable battery, 3.7V/7200mAH
Operating Time: 15 hours with full battery capacity.
(Condition: 25ºC, NIBP working period is 15 minutes)
Recharge Time: 10 hours.

3. Environment
Temperature
Working:0-45c
Transport and Storage: -25-85c
Humidity
Working:30% ~85 %
Transport and Storage: 30% ~95 % (no condensation)

4. Monitoring Parameter


ECG
Input:5- lead ECG cable, standard AAMI cable connector
Lead Selection:I,II,III, avR,avL,avF,C
Gain Selection:×1,×2,×4,×8
Sweep Speed: 12.5, 25, and 50 mm/s
Frequency Response: None filter: 0.05~100Hz (-3dB), filter: 0.5~40Hz (-3dB)
Calibration Signal: 1mV square wave
Protection: Against electrosurgical interference and defibrillation

Heart Rate
Measuring Range: 20 bpm~300 bpm
Renew Time: 1 time per beat
Accuracy: ±1 bpm
Alarm Mode: Audible and visual alarm

SpO2
SpO2%
Measuring Range:0%~100%
Resolution:1 %
Accuracy:±2 %(90%~99%), ±3 %(70%~89%),unspecified (0%~69%)
Pulse Rate
Measuring and Alarm Range:20~300bpm
Resolution: 1bpm
Accuracy: ±1bpm

NIBP
Method: Oscillometric
Mode: Manual, Auto, STAT
Measuring Interval in AUTO Mode: 1, 2, 3, 5, 10, 15, 20, 30, 45, 60 (min)
Measuring Period in STAT Mode: 5 min
Cuff Pressure Range:0 mmHg~300mmHg
Pulse Rate Range:30 bpm~250bpm
Measurement Rage: Adult 30 mmHg~255mmHg, Pediatric 30 mmHg~160mmHg
Over-pressure Protection: Adult 300mmHg, Pediatric 220mmHg
Pressure Resolution : 1mmHg
The SYSTOLIC and DIASTOLIC values measured using this device shall be equal to those measured by trained medical personnel using cuff and stethoscope. The MEAN value measured using this device is equal to that measured using blood pressure measurement device.

Temperature
Input: Body surface thermal-sensitive resistor temperature sensor
Measuring Range: 0ºC~50ºC
Accuracy: ±0.1ºC

EtCO2(Optional)
Measuring Range:  0~150mmHg
Resolution: 1 mmHg
Accuracy: ±2mmHg@< 5.0% CO2
Respiration Rate(Optional)
Measuring Range: 0~120rpm
Resolution: 1rpm
Accuracy: ±1rpm

5. Storage and Review
Maximum Data Quantity: 3888 groups
Maximum Trend Time: Continuous 129.6 hours

6. Printer (optional)
Type: Thermal micro-printer
Printer Paper: 58 mm thermal paper,Paper roll diameter≤Φ 33mm
Interface: Bluetooth wireless interface
Recording Types: Real-time printing and review data printing
Power Supply:
Rechargeable battery 1700mAh~2000mAh.7.2V.  
Charge(discharge) >=1000times.
Charge time: 2hours
Work Operation/relative humidity:0~55ºC/10~80%RH

Storage Operation/relative humidity:-20~60ºC/10~90%RH

Standard accessories


 
Standard Packing List
Color palm patient monitor main unit1 pc
5-lead ECG cable ( include surface TEMP probe)1pc
Adult finger SpO2 sensor1 pc
Adult NIBP cuff1 pc
NIBP extension tube1 pc
USB cable1 pc
AC power adapter1 pc
The operator's manual1 pc
  • Selectable Accessory
Pediatric NIBP cuff 
Pediatric finger Spo2 sensor 
Neonatal wrap SpO2 sensor 
Bluetooth printer 
EtCO2 module(optional)1 pc
Drying tube(optional)2 pcs
Sampling tube(optional)1 pc
Nasal tube(optional)1 pc
3-way elbow(optional)1 pc
Our wide monitor series:

Handheld Bluetooth Medical ICU Patient Monitor with Six-Parameter Function


Warranty:  
1 year for main unit, 6 months for accessories.

Our Image 

Handheld Bluetooth Medical ICU Patient Monitor with Six-Parameter Function




Shipping & Payment 

For total weight over 100kgs, shippment by air or by sea is suggested.


Handheld Bluetooth Medical ICU Patient Monitor with Six-Parameter Function



Contact person:      Yuki

Handheld Bluetooth Medical ICU Patient Monitor with Six-Parameter Function