600kVA 400V Three Phase Low Voltage Anti-Harmonic Reactive Compensation Static Var Generator Svg

China 600kVA 400V Three Phase Low Voltage Anti-Harmonic Reactive Compensation Static Var Generator Svg, Find details about China Harmonic Filter, Svg from 600kVA 400V Three Phase Low Voltage Anti-Harmonic Reactive Compensation Static Var Generator Svg

Model NO.
svg
Three Phase Unbalance
100% Unbalance Full Compensation
Reactive Power Compensation
-100%~+100%(Power Factor Can Be Set)
Instantaneous Response Time
<100us
Total Response Time
<10ms
Communication Interface
RS485 Network Port
Expand Function
The 10 Channel Tsc Interface
Display Interface
3 / 7 Inch Touch Screen
Trademark
wenlida
Transport Package
Wooden
Origin
China
HS Code
85044019
Model NO.
svg
Three Phase Unbalance
100% Unbalance Full Compensation
Reactive Power Compensation
-100%~+100%(Power Factor Can Be Set)
Instantaneous Response Time
<100us
Total Response Time
<10ms
Communication Interface
RS485 Network Port
Expand Function
The 10 Channel Tsc Interface
Display Interface
3 / 7 Inch Touch Screen
Trademark
wenlida
Transport Package
Wooden
Origin
China
HS Code
85044019
Package size per unit product
73.00cm * 65.00cm * 30.00cm
Gross weight per unit product
20.000kg
PRODUCT INTRODUCTION:
      SVG, also known as dynamic reactive power compensation generator, or static synchronous compensator, refers to the device of dynamic reactive power compensation by self commutation power semiconductor bridge converter. The basic principle is that self commutation bridge circuit is composed of turn off, high-power and high-frequency power electronic devices (such as IGBT), which are connected in parallel with the power grid through the reactor. The amplitude and phase of the output voltage at the AC side of the bridge circuit can be adjusted in real time, or the AC side current can be directly controlled, so that the bridge circuit can absorb or send out reactive current to realize dynamic reactive power compensation and voltage Dynamic control and other purposes.

MODEL DESCRIPTION:
600kVA 400V Three Phase Low Voltage Anti-Harmonic Reactive Compensation Static Var Generator Svg

SPECIFICATION SHEET:
Three-phase Three-wire High Voltage SVG
TypeRated voltage
(KV)
Rated current
(A)
Compensation current
(A)
Size(mm)
Width*Height*Depth
remarks
SVG-6/2.461.2±1.22304500*1200*2400In the table is the SVG capacity of chain star connection. The cooling mode is air cooling
SVG-6/4.862.4±2.44604800*1200*2400
SVG-6/864.0±4.07686000*1200*2400
SVG-6/1065.0±5.09607800*1200*2600
SVG-10/2.0101.0±1.01166000*1200*2400
SVG-10/4.0102.0±2.02306000*1200*2400
SVG-10/8.0104.0±4.04607500*1200*2400
SVG-10/10105.0±5.05767500*1200*2400
SVG-35/16358.0±8.02644600*25000area covered
SVG-35/323516±165284600*30000
SVG-35/603530±3010005600*36000
SVG-35/803540±4013368000*18000
Wall mounted
typewidth
(mm)
height
(mm)
depth
(mm)
mounting hole
(mm)
LL1HH1DD1D2di
35kavr381375174170623580550600300
50kvar506500204200623580550600400
75kvar506500244240653616580630400
100kvar506500274270710670638685400
Rack-mounted
typewidth
(mm)
height
(mm)
depth
(mm)
mounting hole
(mm)
LL1HDD1dih1D2
35kvar41537517058055041330035405
50kvar57050020058050053812038.5535
75kvar57050024061658053816040535
100kvar57050027067063853819040535
 
 
TypeRated voltage(V)Rated capacity(KVAR)MinSize(mm)
Width*Height*Depth
SVG-380/200400100±100800*600*2200
SVG-380/300150±1502*(800*600*2200)
SVG-380/400200±2002*(800*600*2200)
SVG-380/600300±3002*(800*600*2200)
SVG-660/200690100±1001000*800*2200
SVG-660/400200±2002*(1000*800*2200)
SVG-660/600300±3003*(1000*800*2200)
SVG-660/800400±4004*(1000*800*2200)
SVG-1140/4001140200±2002*(1000*800*2200)
SVG-1140/800400±4003*(1000*800*2200)
SVG-1140/1200600±6004*(1000*800*2200)
SVG-1140/1600800±8005*(1000*800*2200)
 
PRODUCT PARAMETERS:
Working voltage380V(-40%~+20%) ; 380V(-30%~+15%)
Working frequency50/60Hz±5Hz
Wiring modeThree-phase three-wire ; Three-phase four-wire
Current sampling5A(CT:100/5~10000/5)
Current sampling positionLoad side / grid side optional
Circuit topologyThree level
Number of parallel unitsUnlimited
Switching frequency21.6KHz
Cooling modeIntelligent air cooling
 
TECHNICAL PERFORMANCE:
Filtering range2-13 times(50% of rated current)
Reactive power compensation-100%~+100%(Power factor can be set)
Three phase unbalance100% unbalance full compensation
overload protectionsupport
power factor-1~+1
Instantaneous response time<100us
Total response time<10ms
Noise<70dB
Protection functionOver voltage protection, under voltage protection, short circuit protection, inverter bridge reverse protection, etc
 
COMMUNICATION MONITORING:
Expand functionThe 10 channel TSC interface can operate with TSC / TSF
Communication interfaceRS485 Network port
Communication protocolGeneral agreement on electricity;modbus protocol;YCP/IP
Upper computer softwareYes, all parameters can be set by upper computer
Display interface3 / 7 Inch Touch Screen
Display informationVoltage, current, power, harmonic and other grid parameters
MonitorSupport independent monitoring / centralized monitoring of each module
Fault alarmUp to 500 alarm messages can be recorded

USAGE ENVIRONMENT:

Ambient temperature-20ºC~+45ºC
Storage temperature-40ºC~+65ºC
Relative humidityMaximum 95% frost free
AltitudeBelow 1500m, the power will be reduced by 1% every 100m
Protection levelIP20,Higher protection level can be customized
Installation modeWall mount, rack, whole machine
Incoming line modeBack feed, upper feed

600kVA 400V Three Phase Low Voltage Anti-Harmonic Reactive Compensation Static Var Generator Svg