1000UL Fillter Pipette Tip Sterile Rnase&Dnase Free Low Retention

China 1000UL Fillter Pipette Tip Sterile Rnase&Dnase Free Low Retention, Find details about China 10UL 100UL 200UL 1000UL, Sterile from 1000UL Fillter Pipette Tip Sterile Rnase&Dnase Free Low Retention

Model NO.
10/20/50/100/200/1000 ul
Rnase&Dnase Free
Yes
Name
Pipette Tip
Filter
with Filter and Without
Sterile
Eo
Autoclavable
Yes
Low Retention
Yes
Trademark
BIOLOGIX
Transport Package
100 Racks/Case
Specification
CE, FDA, ISO9001
Origin
Changzhou City, Jiangsu Province, China
Model NO.
10/20/50/100/200/1000 ul
Rnase&Dnase Free
Yes
Name
Pipette Tip
Filter
with Filter and Without
Sterile
Eo
Autoclavable
Yes
Low Retention
Yes
Trademark
BIOLOGIX
Transport Package
100 Racks/Case
Specification
CE, FDA, ISO9001
Origin
Changzhou City, Jiangsu Province, China
1000ul filter tips with RNase&DNase free in stock low retention
1000UL Fillter Pipette Tip Sterile Rnase&Dnase Free Low Retention
1000UL Fillter Pipette Tip Sterile Rnase&Dnase Free Low Retention
1000UL Fillter Pipette Tip Sterile Rnase&Dnase Free Low Retention

Characteristic
 

 Tips are made of PP, filters are made of UHMWPE with pore size 0.22um. 

 Tips all are natural clear color

 10µl, 20µl, 100µl, 200µl, and 1000µl tip sizes available.
 Filters prevent cross-contamination and damage to samples, ensure accurate and precise sample.
 Sterile.
 RNase & DNase free.

    Ordering Information
     
     22-0010 10µl Filter Tips, bulk pack, tip material: DNase & RNase Free, PP, filter material: UHMWPE. Filter diameter: 1.6mm, thickness: 3.5mm, 1000 Pieces/Bag, 10 Bags/Case
     22-0011 10µl Filter Tips, bulk pack, low retention, tip material: DNase & RNase Free,PP, filter material:  UHMWPE. Filter diameter: 1.6mm, thickness: 3.5mm, 1000 Pieces/Bag, 10 Bags/Case
     22-0200 200µl  Filter Tips, bulk pack, tip material: DNase & RNase Free,PP, filter material: UHMWPE. Filter diameter: 4.5mm, thickness: 3.5mm ,1000 Pieces/Bag, 10 Bags/Case
     22-0201 200µl  Filter Tips, bulk pack, low retention, tip material: DNase & RNase Free,PP, filter material:  UHMWPE. Filter diameter: 4.5mm, thickness: 3.5mm, 1000 Pieces/Bag, 10 Bags/Case
     22-1000 1000µl  Filter Tips, bulk pack, tip material: DNase & RNase Free,PP, filter material: UHMWPE. Filter diameter: 7.0mm, thickness: 4.2mm, 1000 Pieces/Bag, 10 Bags/Case
     22-1001 1000µl  Filter Tips, bulk pack, low retention, tip material: DNase & RNase Free,PP, filter material:  UHMWPE. Filter diameter:7.0mm, thickness: 4.2mm, 1000 Pieces/Bag, 10 Bags/Case
     


    1000UL Fillter Pipette Tip Sterile Rnase&Dnase Free Low Retention1000UL Fillter Pipette Tip Sterile Rnase&Dnase Free Low Retention1000UL Fillter Pipette Tip Sterile Rnase&Dnase Free Low Retention1000UL Fillter Pipette Tip Sterile Rnase&Dnase Free Low Retention

    1.What are the main factors that influence the maximum centrifugal acceleration force?
    Use of organic solutions, temperature below 0°C, centrifuging without centrifuge adapter, etc. Conduct a trial run to determine proper conditions before any critical use begins.
    The RCF (relative centrifugal force) or G ratings for our disposable centrifuge tubes have been established at room temperature using tubes filled to nominal capacity with water and centrifuging for 30 minutes. recommended carriers, adapters, and cushions that fully support the tubes. If an angle head rotor is used or proper support is not provided, G values will be lower.
    Do not confuse speed or revolutions per minute (RPM) with relative centrifugal force (RCF). Instructions for centrifuging a sample at a given RPM and time are incomplete unless the rotor or radius is specified. Protocols should always state the time and RCF value for centrifuging a sample.

    2.What are autoclaving guidelines of plastics?

    To ensure successful steam sterilization of your plastic labware please adhere to the following guidelines: PLEASE NOTE THAT NOT ALL PRODUCTS ARE AUTOCLAVABLE. Autoclave plastic consumables at 121°C and 15psi/1 atm for 15 minutes. Do not use a dry cycle, as this may cause deformation or weakening of the plastic. Allow temperature within the autoclave to return to 80°C or below before removing products.

    3.What are Biologix's Commitments to Quality?
    We look at quality from every angle in terms of functionality, safety, purity, formulation, consistency, manufacturing, customer service, technical support, and much more. According to the detailed QA/QC procedures for our manufacturing facility, each and every product is traceable by lot, regardless of packaging format. Products must go through a five-step human inspection before being released for packaging. Biologix applies the most stringent standards to certify that products are free from RNase, DNase, endotoxin (pyrogens), etc. In addition to being ISO 9001:2008, CE compliant, we also make available to our customers lot-specific certificates such as Sterilization Certificates, Nuclease Free Certificates, Certificates of Origin, etc.