China Flexible Copper Wire PVC Insulated Electrical Cable, Find details about China Flexible Cable, Electrical Cable from Flexible Copper Wire PVC Insulated Electrical Cable
Size of conductor | Nominal thickness of insulation mm | Mean overall diameter Upper limit mm | renmincable.en.made-in-china.com weight per km kg | |
Nominal cross-sectional area mm2 | Number and diameter of wires no./mm | |||
1.0 | 32/0.20 | 0.6 | 3.0 | 16 |
1.5 | 30/0.25 | 0.7 | 3.5 | 21 |
2.5 | 50/0.25 | 0.8 | 4.2 | 33 |
4 | 56/0.30 | 0.8 | 4.8 | 50 |
6 | 84/0.30 | 0.8 | 6.3 | 70 |
10 | 80/0.40 | 1.0 | 7.6 | 120 |
16 | 126/0.40 | 1.0 | 8.8 | 175 |
25 | 196/0.40 | 1.2 | 11.0 | 290 |
35 | 276/0.40 | 1.2 | 12.5 | 400 |
50 | 396/0.40 | 1.4 | 14.5 | 565 |
70 | 360/0.50 | 1.4 | 17.0 | 770 |
95 | 475/0.50 | 1.6 | 19.0 | 1010 |
120 | 608/0.50 | 1.6 | 21.0 | 1260 |
150 | 756/0.50 | 1.8 | 23.5 | 1580 |
185 | 925/0.50 | 2.0 | 26.0 | 1900 |
240 | 1221/0.50 | 2.2 | 29.5 | 2500 |
Size of conductor | Nominal thickness of insulation mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross-sectional area mm2 | Number and diameter of wires no/mm | Lower Limit mm | Upper Limit Mm | ||
0.5 | 28/0.15 | 0.8 | 2.5x5.0 | 3.0x6.0 | 24 |
0.75 | 42/0.15 | 0.8 | 2.7x5.4 | 3.2x6.4 | 29 |
Size of conductor | Nominal thickness of insulation mm | Mean overall diameter Upper limit mm | Approx. net weight per km kg | |
Nominal cross-sectional area mm2 | Number and diameter of wire no/mm | |||
0.5 | 16/0.20 | 0.6 | 2.6 | 10 |
0.75 | 24/0.20 | 0.6 | 2.8 | 13 |
1.0 | 32/0.20 | 0.6 | 3.0 | 16 |
1.5* | 30/0.25 | 0.7 | 3.5 | 20 |
2.5* | 50/0.25 | 0.8 | 4.2 | 32 |
4.0* | 56/0.30 | 0.8 | 4.8 | 49 |
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires No./mm | Upper Limit mm | Upper Limit mm | |||
0.5 | 16/0.20 | 0.5 | 0.6 | 3.0x4.8 | 3.6x6.0 | 27 |
0.75 | 24/0.20 | 0.5 | 0.6 | 3.2x5.2 | 3.9x6.4 | 34 |
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires No./mm | Upper Limit mm | Upper Limit mm | |||
0.5 | 16/0.20 | 0.5 | 0.6 | 4.8 | 6.0 | 36 |
0.75 | 24/0.20 | 0.5 | 0.6 | 5.2 | 6.4 | 45 |
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of Sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires no/mm | Lower Limit mm | Upper Limit mm | |||
0.5 | 16/0.2 | 0.5 | 0.6 | 5.0 | 6.2 | 44 |
0.75 | 24/0.2 | 0.5 | 0.6 | 5.4 | 6.8 | 55 |
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires no/mm | Lower Limit mm | Upper Limit mm | |||
0.75 | 24/0.20 | 0.6 | 0.8 | 6.0 | 7.6 | 63 |
1.0 | 32/0.20 | 0.6 | 0.8 | 6.4 | 8.0 | 73 |
1.25 | 40/0.20 | 0.7 | 0.8 | 7.0 | 8.6 | 84 |
1.5 | 30/0.25 | 0.7 | 0.8 | 7.4 | 9.0 | 95 |
2.5 | 50/0.25 | 0.8 | 1.0 | 8.9 | 11.0 | 145 |
Size of conductor | Nominal thickness of insulation mm | Nominal thickness of sheath mm | Mean overall dimensions | Approx. net weight per km kg | ||
Nominal cross- sectional area mm2 | Number and diameter of wires no/mm | Lower limit mm | Upper limit mm | |||
0.75 | 24/0.20 | 0.6 | 0.8 | 6.8 | 8.6 | 78 |
1.0 | 32/0.20 | 0.6 | 0.9 | 7.6 | 9.4 | 110 |
1. 5 | 30/0.25 | 0.7 | 1.0 | 9.0 | 11.0 | 150 |
2.5 | 50/0.25 | 0.8 | 1.1 | 10.5 | 13.0 | 220 |