China TBB 8kw Hybrid off Grid Solar Energy Systems 8000W Solar Panel Generation System 8kVA Solar Power Stations for Air Conditioners, Find details about China Solar Power Station, Solar Power Generator Systems from TBB 8kw Hybrid off Grid Solar Energy Systems 8000W Solar Panel Generation System 8kVA Solar Power Stations for Air Conditioners
Off-Grid/Hybrid Solar Energy System | ||||||
Kinergier Pro(CK CK-II) Series NON-MPPT Inverter Charger | ||||||
Components | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW |
AC outputs | 220-240V 50/60HZ | 220-240V 50/60HZ | 220-240V 50/60HZ | 220-240V 50/60HZ | 220-240V 50/60HZ | 220-240V 50/60HZ |
Three Phase & Parallel | Parallel Yes | Parallel Yes | Parallel Yes | Parallel Yes | Parallel Yes | Parallel Yes |
Solar Panel | 3 PCS | 6 PCS | 9 PCS | 12 PCS | 15 PCS | 18 PCS |
Hybrid Inverter | 2KW-M/S | 3KW-M/S | 4KVA-S | 5KW-S | 6KVA-S | 8KVA-S |
Solar Mate | 150Vdc 60A | 150Vdc 60A | 150Vdc 60A | 150Vdc 60A | 150Vdc 60A | 150Vdc 100A |
Lithium Battery | 48V 3.6KWH | 48V 4.8KWH | 48V 7.2KWH | 48V 10.8KWH | 48V 10.8KWH | 48V 18KWH |
DC Combiner Box | 1 Piece | 1 Piece | 1 Piece | 1 Piece | 1 Piece | 1 Piece |
Solar Panels Rack | 1 set | 1 set | 1 set | 1 set | 1 set | 1 set |
PV cable 4mm² | 50-100m | 50-100m | 50-100m | 50-100m | 50-150m | 50-150m |
MC4 Connector | 1 Pieces | 2 Pieces | 3 Pieces | 4 Pieces | 5 Pieces | 6 Pieces |
Installation Tool | 1 set | 1 set | 1 set | 1 set | 1 set | 1 set |
Model | CK4.0M | CK5.0M | CK 4.0S | CK 5.0S | CK 6.0S | CK 8.0S |
Power Assist | Yes | |||||
Feed-in to grid | Yes | |||||
AC input voltage range(VAC) | 175~265 | |||||
AC input Frequency range(Hz) | 45~65 | |||||
AC input Current (transfer switch) (A) | 50 | |||||
Inverter | ||||||
Nominal battery voltage (VDC) | 24 | 48 | ||||
Input voltage range (VDC) | 21-34 | 42~68 | ||||
AC output voltage(VAC) | 220/230/240 ± 2% | |||||
AC output Frequency(Hz) | 50/60 ± 0.1% | |||||
Harmonic distortion | <2% | |||||
Load Power factor | 1.0 | |||||
Cont. output power at 25°C (VA) | 4000 | 5000 | 4000 | 5000 | 6000 | 8000 |
Cont. output power at 25°C (W) | 3600 | 4500 | 3200 | 4000 | 4800 | 6500 |
Peak power (30min) (W) | 4000 | 5000 | 4000 | 5000 | 6000 | 8000 |
Peak power (W) | 8000 | 10000 | 8000 | 10000 | 12000 | 16000 |
Cont. output power at 40°C (W) | 2800 | 3600 | 2800 | 3500 | 4200 | 5600 |
Surge | 300% | |||||
Maximum efficiency | 94% | 96% | ||||
Zero load power (W) | 18 | 23 | 17 | 19 | 20 | 26 |
Charger | ||||||
Charge voltage 'absorption' (VDC) | 28.8 | 57.6 | ||||
Charge voltage 'float' (VDC) | 27.6 | 55.2 | ||||
Battery types | AGM / GEL / OPZV / Lead-Carbon / Li-ion / Flooded/Traction/TBB SUPER-L | |||||
Max AC charge current (A) | 120 | 150 | 55 | 70 | 80 | 110 |
Temperature compensation | Yes | |||||
General data | ||||||
Main Output (AC Out1) Current (A) | 50 | |||||
Auxiliary Output (AC Out2) Current (A) | 32 | |||||
Transfer time | 0ms (<15ms in Weak AC source Mode) | |||||
Remote on-off | Yes | |||||
Programmable relay | 2x | |||||
Protection | a) output short circuit, b) overload, c) battery voltage too high, d) battery voltage too low, e) temperature too high, f) input voltage out of range, g) input voltage ripple too high, h) Fan block | |||||
CAN Bus communication port | For parallel and three phase operation, remote monitoring and system integration | |||||
General purpose com. Port | RS485 (GPRS,WLAN optional with kinergy) | |||||
Operating temperature range | -20˚C~65˚C | |||||
Relative humidity in operation | 95% without condensation | |||||
Altitude (m) | 2000 | |||||
Mechanical Data | ||||||
Dimension (mm) (max) | 530*285*185 | |||||
Net Weight (kg) | 33 | 36 | 30 | 33 | 35 | 40 |
Cooling | Forced fan | |||||
Protection Category | IP20 | |||||
Standards | ||||||
Safety | EN60950-1 | |||||
EMC | EN61000-6-2,EN61000-6-4, EN61000-3-11,EN61000-3-12 | |||||
To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging services will be provided.