Fu-55 Dry Type Split Core Current Transformer

China Fu-55 Dry Type Split Core Current Transformer, Find details about China Split Core CT, Open Core CT from Fu-55 Dry Type Split Core Current Transformer

Model NO.
Split Core CT
Insulating Medium
Epoxy Resin
Installation
Suspension, Use The Screws to Tighten The Opening
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Characteristic and Application
Avaliable for Cable That Under 1000 Online Measure
Overall Dimensions
108mmx155mmx28mm
Output Mode
Terminal Output
Accuracy
0.5
Ratio
400/5A, 600/5A, 1000/5A, 200/1A
Color
Black
Weight
550g
Trademark
GFUVE
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Origin
Beijing, China
Model NO.
Split Core CT
Insulating Medium
Epoxy Resin
Installation
Suspension, Use The Screws to Tighten The Opening
Magnetic Circuit Structure
Single Stage Type
Voltage Transformation Principle
Electromagnetic Type
Characteristic and Application
Avaliable for Cable That Under 1000 Online Measure
Overall Dimensions
108mmx155mmx28mm
Output Mode
Terminal Output
Accuracy
0.5
Ratio
400/5A, 600/5A, 1000/5A, 200/1A
Color
Black
Weight
550g
Trademark
GFUVE
Transport Package
Standard Export Carton
Specification
CE, ISO9001: 2008, IEC
Origin
Beijing, China
Fu-55 200/1A class 0.5 2.5VA Dry Type Split Core Current Transformer
Fu-55 Dry Type Split Core Current Transformer
Fu-55 Dry Type Split Core Current Transformer
Characteristic and application: Avaliable for cable that under 1000A online measurement
Diameter of clamping wire: φ 55MM
Overall dimensions: 108MMx155MMx28MM
Load capacity: ≤ 4Ω (MA output), 0.1Ω (1A output), 2.5VA(5A output)
Installation: Suspension, use the screws to tighten the opening, can be equipped with mounting bracket
Output mode: Terminal output
Technical parameter
Technical parameters 
StandardsIEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13
Ratio400: 5 or 400:1 , customized
Nominal input current(Primary current)200A/300A/400A/500A/600A/800A/1000A
Overload withstand1.2 times rated current continuously
Accuracy0.2%, 0.5 %, 1%
System Voltage720V(0.72kV)
Output signal1A or 5A
333mV AC or 100mV-2V optional
Burden2.5VA
Frequency range40 Hz....500 Hz
Dielectric strength3KV 50Hz/60Hz  at 1 minute
Output modeTerminal output
Max. jaw opening55 mm
Mechanical parameters 
Dimensions (W×D×H) (mm)108mm x 155mm x 28 mm
Weight (g)550
Operating conditions 
Operating temperature-25 to +55°C
Relative Humidity0-85% non-condensing
Altitude<3500 meters
ConditionNo existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current.