10kVA 100kv High Voltage Transformer AC DC Hipot Test Equipment

China 10kVA 100kv High Voltage Transformer AC DC Hipot Test Equipment, Find details about China Hipot Tester, Hipot Test from 10kVA 100kv High Voltage Transformer AC DC Hipot Test Equipment

Model NO.
SXTC
Loading Method
Static Load
Display
LCD
Control
Computer Control
Weight
0-100Kg
Power Source
AC 110V/220V at Customized
Control Mode
Manual/Auto
Transformer Type
Oil, Gas, Dry Is at Customized
Box Type
5kVA or Below
Table Type
10kVA or Above
Cabinet Type
50kVA or Above
Trademark
Sansion
Transport Package
Plywood Case
Specification
ISO9001 SGS
Origin
Wuhan, China
HS Code
9030339000
Model NO.
SXTC
Loading Method
Static Load
Display
LCD
Control
Computer Control
Weight
0-100Kg
Power Source
AC 110V/220V at Customized
Control Mode
Manual/Auto
Transformer Type
Oil, Gas, Dry Is at Customized
Box Type
5kVA or Below
Table Type
10kVA or Above
Cabinet Type
50kVA or Above
Trademark
Sansion
Transport Package
Plywood Case
Specification
ISO9001 SGS
Origin
Wuhan, China
HS Code
9030339000
10kVA 100kV High Voltage Transformer AC DC Hipot Test Equipment

General information:

SXTC-M Series AC/DC Hipot Test Set is suitable for hipot dielectric withstand test on various power electric products, units, insulating material and etc. 
 
Features:
√    Manual/Auto controlling.
√    Oil, dry, SF6 gas type transformer is seletable according to user's requirements.
√    High anti interference ability.
√    High voltage (HV) voltage, Low voltage (LV) current, time, three channels testing ways.
√    Real time monitoring HV voltage, LV current.
√    Full protection functions: over-current, zero-starting sound light alarm, power switch protection.
√    New type time rely, wider time range (1S ~ 99H).
√    New type current rely, more precise, more reliable.
√    5kVA and above Testing Transformer with movable iron wheel. Light weight, small size, easy to move, superior performance.
√    The control tester can be designed to box type, table type, or cabinet type according to user's testing capacity:
     5KVA or below, Box type
     10KVA or above Table type
     50KVA or above Cabinet type.
√    Add rectifying installation to support AC/DC function .(option)

Specifications:
√    Input voltage: AC 220(380)V (customized)
√    LV output: AC 0-250(430)V
√    LV current: 0-5/10/15/50A (customized)
√    Output capacity: 0-3/5/10/15 kVA (customized)
√    HV output: 0-50/100/150/200 kV (customized)
√    HV current: 0-50/100/150/200/500/1000/2000mA (customized)
√    Timing range: 0-9999S
√    Working temperature: -20ºC to 50ºC
√    Voltage precision: ≤1.5% ±1 digit (F.S)
√    Current precision: ≤1.5% ±1digit (F.S)

Main parameters of SXTC-M Control Unit:
ModelInput Voltage
(V)
Capacity
(KVA)
Rated OutputHV voltmeter
KV/V
Oversize
m3(L×W×H)
Voltage(v)Current(A)
SXTC-M052200.52002.550/10020×30×20
SXTC-M1052201.52007.550/10026×36×24
SXTC-M322032001550/10026×42×24
SXTC-M622062003050/10060×45×37
SXTC-M622062003050/10053×40×60
SXTC-M102201020050/25(50/100)/10053×40×65
SXTC-M153801540037.5(50/100/150)/10053×40×70
SXTC-M203802040050(50/100/150)/10053×43×84
SXTC-M253802540062.5(50/100/150)/10053×45×90
SXTC-M303803040067.5(50/100/150)/10065×55×115
SXTC-M4038040400100(50/100/150)/10070×60×115
SXTC-M5038050400125(50/100/150)/10070×60×115
The rated output current is 5 min continuous working.

More information, please kindly contact with us, we can customize the suitable test set according your requirements and give you the best quotation. Thank you! 
10kVA 100kv High Voltage Transformer AC DC Hipot Test Equipment