Permanent Magnet Generator 200kw Brushless Alternator

China Permanent Magnet Generator 200kw Brushless Alternator, Find details about China Alternator, Brushless Alternator from Permanent Magnet Generator 200kw Brushless Alternator

Model NO.
JET274H
Insulation Class
H Class
Alternator Type
Brushless Synchronous Alternator
Rotor and Stator
100% Copper Wire
Rated Speed
1500rpm / 1800rpm
Protection Class
IP21 / IP23
Generator Warranty
1 Year or 1000 Working Hours
Manufacturing Standard
GB755, Part 3 of BS5000, VDE0530, Ute5100, NEMA
Coil Winding
2/3 Pitch Winding Design
Frequency
50Hz / 60Hz
Excitation Type
Brushless Self-Excitation with AVR
Trademark
JET POWER
Transport Package
Plywood Case
Specification
6.5KW to 1100KW Stamford type alternator
Origin
China
HS Code
8502110000
Model NO.
JET274H
Insulation Class
H Class
Alternator Type
Brushless Synchronous Alternator
Rotor and Stator
100% Copper Wire
Rated Speed
1500rpm / 1800rpm
Protection Class
IP21 / IP23
Generator Warranty
1 Year or 1000 Working Hours
Manufacturing Standard
GB755, Part 3 of BS5000, VDE0530, Ute5100, NEMA
Coil Winding
2/3 Pitch Winding Design
Frequency
50Hz / 60Hz
Excitation Type
Brushless Self-Excitation with AVR
Trademark
JET POWER
Transport Package
Plywood Case
Specification
6.5KW to 1100KW Stamford type alternator
Origin
China
HS Code
8502110000
Detailed description
1.Brushless synchronous alternator with Stamford technology.
2.Output range:6.5kw - 1150kw single-phase and three-phase
3.High-performance Convenient installation and maintenance 
4.Three phase 4 wire, optional 50Hz/60Hz, 1500/1800RPM
5.4-pole, brushless alternator with AVR, H class insulation, IP21
6. Be suitable for various brands engine, international standard SAE port, double bearing as optional
Specifications:
 
MODEL3-PHASE 50Hz /1500RPM 380V-440V3-PHASE 60Hz /1800RPM 440V-480VDIMENSIONWEIGHT
(KVA)(KW)(KVA)(KW)CMKG
JET 164A8.16.510.28.264×54×7295
JET 164B118.813.81164×54×72102
JET 164C13.510.816.913.564×54×72110
JET 164D1612.8201664×54×72116
JET 184E22.51828.82384×59×75133
JET 184F27.52234.427.584×59×75156
JET 184G31.32537.53084×59×75172
JET 184H37.53046.937.584×59×75226
JET 184J4032504084×59×75236
JET 224C42.53452.54296×66×102275
JET 224D504062.55096×66×102295
JET 224E6048705696×66×102315
JET 224F72.55887.57096×66×102345
JET 224G856897.57896×66×102385
JET 274C1008011894126×76×102415
JET 274D11491138110126×76×102435
JET 274E140112168134126×76×102485
JET 274F160128190152126×76×102530
JET 274G175140213170126×76×102580
JET 274H200160245196126×76×102630
JET 274J230184281224.8130×76×102750
JET 274K250200299239.2130×76×102760
JET 444C250200294235151×79×107880
JET 444D295236350280151×79×107950
JET 444E325260394315151×79×1071065
JET 444FS380304456365151×79×1071145
JET 444F400320480384151×79×1071185
JET 544C450360550440165×95×1161350
JET 544D500400594475165×95×1161450
JET 544E600480713570165×95×1161700
JET 544FS625500725580165×95×1161753
JET 544F670536775620165×95×1161820
JET 634B750600855684180×100×1452020
JET 634C800640916732.8180×100×1452050
JET 634D9107281034834.2180×100×1452100
JET 634E10008001145916180×100×1452260
JET 634F113090412741019.2180×100×1452490
JET 634G1250100013861108.8180×100×1452820

JET Series Brushless Synchronous Alternator are made adopted Stamford alternators technology and according to the standards of GB755,IEC60034,NEMA etc. The alternators have standard features: voltage adjust, stability adjust, under frequency roll off, over exciting protection, low radio interference, etc. The stators are 2/3 pitch winding, the rotors are fixed sequential damper winding. The stator core is designed landler taking advantage of CAD, ensuring a very low waveform distortion. "H" class insulation system is provided the high build required for static windings and the high mechanical strength required for rotating components.
Alternator Features:
 
1)Advanced automatic voltage regulator control for trouble-free operation under the most demanding condition
2)Easy paralleling with mains or other generators .Standard 2/3 pitch windings avoid excessive neutral currents. 
3) Dynamically balanced rotor, with sealed-for-life ball bearings and single or two-bearing construction.
4)Simple installation and maintenance with easy access to terminals, rotating diodes and coupling bolts.
5)Wide range of Flange adaptor and single bearing coupling disc.
 
MECHANICAL FEATURES
 
Voltage regulation
 
Voltage regulation refers to the change of voltage from no-load to full-load with power factor ranging from 0.5 to 1 and 2.8%s fluctuation of the speed of engine. Voltage is adjusted via potentiometer of AVR, model: SX460, SX440
 
Axis and Key
 
All of alternator rotors should pass balance test, whose vibrations are lower than the minimum of BS6861 P.1,G 2.5 two bearing alternator has a half-key testing balance
 
Terminal and terminal box
 
The three-field alternator had 12 leads brought out to the terminals in the terminal box. The terminals are put on the non drive end . The box is equipped with removable panels.
 
 
ELECTRIC FEATURES
Insulation Class H
 
All regulatory components are made up with special materials and are immersed in lacquer by peculiar tech. Vanish and colophony materials are develop to strengthen the processing and machinery intensity of windings and revolving parts for protecting the alternator work under corrosive environment.
 
Winding and electric features
 
2/3 pith winding design can effectively eliminate the third harmonic wave(3th.9th,15th) of the voltage ,which is the best design of UPS for nonlinear load .Connected with the network in parallel, the structure can restrain excessive currents in the midline. This and the 2/3 pitch help to check the wave distortion and output voltage.
 
Phone interference and Radio interference
 
THF (defined by 40thpart of BS4999) <2%.TIF<50
Brushless apparatus and quality AVR ensure little radio interference in transmission. RFI noise filter is also available.
 
Accessories & Option
 
Droop kit for sharing of reactive current during parallel operation
Remote voltage potentiometer
PT100 thermal protection embedded in stator windings
Anti condensation heaters
IP23 protection
Special treatment for damp-saline or corrosive Environment
PMG
Control panel with LCD digital meter
 
Manufacturing Standard
 
GB755, PART 3 of BS5000, VDE0530, UTE5100, NEMA MG1-22, CEMA, IEC34-1, CSA22.2 and AS1359.
 
Warranty policy
 
JET product has guarantee for one year or 1200 hours whichever reach first from ex-factory date. During the guarantee period, our will provide the free easy-damageable spare parts of alternator caused by our quality of production or raw material. After expiration, our provides cost spare parts maintenance of alternator.
 
60kVA 75kVA 85kVA 100kVA 125kVA Stamford Brushless AC Alternator

60kVA 75kVA 85kVA 100kVA 125kVA Stamford Brushless AC Alternator
60kVA 75kVA 85kVA 100kVA 125kVA Stamford Brushless AC Alternator