ITEM The amount of water produced | KLX-50 | KLX-100 | KLX-200 | KLX-300 | KLX-500 |
Water production flow range(m3/h) | 0.5-0.7 | 0.7-1.2 | 1.5-2.5 | 2.0-3.5 | 3.5-5.5 |
Standard water flowjnf/h) | 0.5 | 1 | 2 | 3 | 5 |
Hydropower resistance(MQ • cm) | >15 | >15 | >15 | >15 | >15 |
Silicon boron removal rate(%) | N99 | N99 | N99 | >99 | >99 |
Inflow requirements | | KLX-50 | KLX-100 | KLX-200 | KLX-300 | KLX-500 |
Temperature range (*C) | 15-35 (25 optimal) | 15-35 (25 optimal) | 15-35 (25 optimal) | 15-35 (25 optimal) | 15-35 (25 optimal) |
Inflow PH | 6.5-9.0 | 6.5-9.0 | 6.5-9.0 | 6.5-9.0 | 6.5-9.0 |
Electric conductivity (p S/cm) | 1-25 (optimal<5) | 1-25 (optimal<5) | 1-25 (optimal<5) | 1-25 (optimal<5) | 1 -25 (optimal<5) |
Total carbon dioxide (ppm) | <3 (optimal<2) | <3 (optimal<2) | <3 (optimal<2) | <3 (optimal<2) | <3 (optimal<2) |
Total hardness (ppm) | <1 | <1 | <1 | <1 | <1 |
Siliconactive silica (ppm) | WO.5 (optimalw0.2 | WO.5 (optimal^0.2) | WO.5 (optimalw0.2) | <0.5 (optimal<0.2) | WO.5 (optimalw0.2) |
Total organic carbon (ppm) | W0.5 | W0.5 | W0.5 | W0.5 | W0.5 |
Residual chlorine (ppm) | W0.05 | W0.05 | W0.05 | W0.05 | W0.05 |
Metal ion (Fe/Mn.ppm) | W0.01 | W0.01 | W0.01 | W0.01 | W0.01 |
Turbidity (NTU) | <1 | <1 | <1 | <1 | <1 |
Lipid | Not detected | Not detected | Not detected | Not detected | Not detected |
PM (um) | W1.0 (optimal w0.5) | w 1.0 (optimal w 0.5) | w1.0 (optimalw0.5) | w1.0 (optimalw0.5) | w1.0 (optimalw0.5) |
Oxidant | Not detected | Not detected | Not detected | Not detected | Not detected |
Operating parameters | KLX-50 | KLX-100 | KLX-200 | KLX-300 | KLX-500 |
Fresh water output pressure (Din, bar) | 1-5 | 1-5 | 1-5 | 1-5 | 1-5 |
Fresh water intake pressure (Cin, bar) | 0.5-1.0 lower than Din | 0.5-1.0 lower than Din | 0.5-1.0 lower than Din | 0.5-1.0 lower than Din | 0.5-1.0 lower than Din |
Fresh water output pressure (Dout, bar) | 0.5-2 | 0.5-2 | 0.5-2 | 0.5-2 | 0.5-2 |
Concentrated water output pressure (Gout, bar) | 0.5-1 .Glower than Dout | 0.5-1.0 lower than Dout | 0.5-1.0 lower than Dout | 0.5-1.0 lower than Dout | 0.5-1.0 lower than Dout |
Working voltage (VDC) | 10-50 | 30-80 | 50-100 | 60-120 | 80-160 |
Running current (A) | 2-5 | 2-5 | 2-5 | 2-5 | 2-5 |
Recovery rate (%) | 85-95 | 85-95 | 85-95 | 85-95 | 85-95 |