China Hot Sell Total Station Nikon Dtm 352, Find details about China Total Station, Nikon from Hot Sell Total Station Nikon Dtm 352
±(3+2ppm x D)mm distance measurement accuracy
Same distance accuracy for both Prisms and Reflector Sheet
Just 1.6 sec. measuring time with 1mm distance resolution
5-second angle measurement accuracy
Quick and convenient feature code input system
USR user defined keys set as "ONE-TOUCH access" keys to your preferred functions
User customizable feature code list
First, on-site setting change capability
Feet & Inch input and display
A special version of the DTM-352 that allows operation at extremely low temperatures down to -30°C is available.
SPECIFICATION :
Model | DTM-362, DTM-352, DTM-332 |
Tube Length | 158mm/6.22 in. |
Magnification | 33x (21x/41x with optional eyepieces) |
Effective diameter of objective | 45mm/1.77 in. (EDM: 50mm/1.97 in.) |
Field of view | 1°20' |
Resolving power | 2.5" |
Minimum focusing distance | 1.3m/4.26 ft. |
Range with Nikon specified prisms | |
Normal conditions | (Ordinary haze, visibility approx. 20km/12.5 miles) |
With reflector sheet | 5 to 100m (16.4 to 328 ft.) |
With mini prism | 1,000m/3,280 ft. |
With single prism | 2,000m/6,560 ft |
With triple prism | 2,600m/8,530 ft. |
Good conditions | (No haze, visibility of over 40km/25 miles) |
With mini prism | 1,200m/3,930 ft. |
With single prism | 2,300m/7.540 ft. |
With triple prism | 3,000m/9,840 ft. |
Accuracy (Prism/Precise mode) | ±(3+2ppm x D)mm (-20°C to -10°C, +40°C to +50°C |
Measuring interval*1 | |
Precise mode | 1.6 sec. (initial 1.6 sec.) |
Normal mode | 1.0 sec. (initial 1.4 sec.) |
Least count | |
Precise mode | 1mm/0.002 ft. |
Normal mode | 10mm/0.02 ft. |
Ambient temperature | -20°C to 50°C/-4°F to +122°F |
Atmospheric correction | |
Temperature range | -40°C to 60°C/-40°F to +140°F |
Barometric pressure | 400 to 999mmHg/533 to 1,332hPa/15.8 to 39.3 in.Hg |
Prism offset | -999 to 999 |
Angle measurement | |
Reading system | Photoelectric detection by incremental encoder |
Horizontal angle | Diametrical(DTM-362/352), Single(DTM-332) |
Vertical angle | Single |
Minimum increment | Degree: 1/5/10", Gon: 0.2/1/2mgon, MIL6400: 0.005/0.02/0,05mil |
DIN 18723 accuracy | 5"/1.5mgon (3"/1.0mgon:DTM-362) |
Tilt sensor | |
Type | Dual-axis(DTM-362/352), Single-axis(DTM-332) |
Method | Liquid-electric detection |
Compensation range | ±3' |
Setting accuracy | 1" |
Level vial | |
Plate level vial | 30"/2mm |
Circular level vial | 10'/2mm |
Optical plummet | |
Magnification | 3x |
Focusing range | 0.5m/1.6 ft. to ∞ |
Display | Graphic LCD (128 x 64 dot) Single side(DTM-332) |
Point memory | 10,000 records |
Dimensions (W x D x H) | 168 x 173 x 335mm/6.6 x 6.8 x 13.2 in. |
Weight (approx.) | |
Main unit (with battery) | 5.3kg/11.7 lbs.(DTM-362/352), |
Battery | 0.4kg/0.9 lbs |
Carrying case | 2.4kg/5.3 lbs |
On-board Ni-MH battery | |
Operation time | |
Continuous distance/angle | Approx. 16 hours*3 |
Distance/angle | Approx. 27 hours |
Angle measurement | Approx. 30 hours |
Battery charger for BC-80/65 | Approx. 2.0 hours for full recharge |
Quick charger Q-70C (12V DC cigarette lighter charger) | Approx. 2.0 hours (fully discharged BC-65 requires more than one charge) |