Hospital Vertical Air Supply Laminar Flow Hood

China Hospital Vertical Air Supply Laminar Flow Hood, Find details about China Class 100 Clean Bench, Laminar Flow Hood from Hospital Vertical Air Supply Laminar Flow Hood

Model NO.
SW-CJ-1F
Product Name
Laminar Flow Cabinet
Model Number
Sw-Cj-1f
Application
Single Person Use- Two Sides Operation Sides
Air Supply
Vertical Air Supply
Cleaning Level
Class 100
Cerification
CE
Work Area Size
880*650*580mm
Overall Dimension
1040*720*1600mm
HEPA Filter Size
865*555*50mm
Voltage
220V/50Hz,110V/60Hz
Display
LCD Screen Touch Button Display
Trademark
SUGOLD
Transport Package
Wooden
Specification
1040*720*1600mm
Origin
Zhejiang China
HS Code
8414609090
Model NO.
SW-CJ-1F
Product Name
Laminar Flow Cabinet
Model Number
Sw-Cj-1f
Application
Single Person Use- Two Sides Operation Sides
Air Supply
Vertical Air Supply
Cleaning Level
Class 100
Cerification
CE
Work Area Size
880*650*580mm
Overall Dimension
1040*720*1600mm
HEPA Filter Size
865*555*50mm
Voltage
220V/50Hz,110V/60Hz
Display
LCD Screen Touch Button Display
Trademark
SUGOLD
Transport Package
Wooden
Specification
1040*720*1600mm
Origin
Zhejiang China
HS Code
8414609090
Hospital vertical air supply laminar flow hood

This is a kind of clean bench widely used in medical treatment, chemical experiment, electron, precise machinery, instrument, apparatus, medical preparation, operating room, foodstuff, drinks, daily-use cosmetic, stock raising and aviation, as well as providing germfree dustless clean environment.

Characteristics
1. Adopting arbitrary positioning sliding door system
2. The shell is welded by cold-rolled plates, the surface is electrostatically sprayed, and the work surface is SUS304 brushed stainless steel, which is corrosion-resistant and easy to clean.
3. The lighting and sterilization systems are interlocked safely, and there is a timing function of ultraviolet light
4. Digital display LCD control interface, more user-friendly design
5. The vertical quasi-closed table top and the formation of a downward flow air curtain in the operation room can effectively prevent the input of external air and the operation area is clean
6. Equipped with HEPA filter, with primary filter for preliminary filtration, which can effectively extend the service life of the HEPA filter life span
ModelSW-CJ-1F 
Cleaning levelGrade 100(209E U.S. Federal)
Number of bacteria≤0.5per utensil.hour(90mm utensil)
The average wind speed0.25~0.45m/s(Speed two-speed)
Noise≤62dB
Power supplyAC, 220 V/50Hz
Illumination≥300LX
Half ventilation peak value≤ 3μm(XYZ direction)
Dimension of working area(W1×D1×H1)880*650*580mm
Overall dimension W*D*H1040*720*1600mm

Hospital Vertical Air Supply Laminar Flow HoodHospital Vertical Air Supply Laminar Flow HoodHospital Vertical Air Supply Laminar Flow HoodHospital Vertical Air Supply Laminar Flow HoodHospital Vertical Air Supply Laminar Flow HoodHospital Vertical Air Supply Laminar Flow HoodHospital Vertical Air Supply Laminar Flow HoodHospital Vertical Air Supply Laminar Flow Hood