Cryogenic Extended Bonnet Globe Valve 2 Inch ANSI 150

China Cryogenic Extended Bonnet Globe Valve 2 Inch ANSI 150, Find details about China Vf45 Mixed Control Valve, Series Control Valve from Cryogenic Extended Bonnet Globe Valve 2 Inch ANSI 150

Material
Stainless Steel
Type
Double Seater
Size
DN50-300 Pn16-100
Trademark
HUIZHENG
Transport Package
Wooden Case
Specification
DN50-300 PN16-100
Origin
China
HS Code
8481804090
Material
Stainless Steel
Type
Double Seater
Size
DN50-300 Pn16-100
Trademark
HUIZHENG
Transport Package
Wooden Case
Specification
DN50-300 PN16-100
Origin
China
HS Code
8481804090
Cryogenic Extended Bonnet Globe Valve 2 Inch ANSI 150

VF45 Mixed valve series High closing force flange type two way regulating valve

 

Composition of SDCHENXUAN  Temperature Control Valve

Controller:
 Accept the temperature signal and output 0...10V control signal through P/PI/PID operation.  Common models of Siemens controllers include  RWD60 \ RWD 62 \ RWD68 \ RLU36 \ MZ730 - b, etc.
Actuator:
 Accept the adjustment signal sent by the controller, accurately adjust the valve opening, stable operation, optional power-off reset, 3P or analog adjustment, 230DCV or 24DCV power supply.  The common models of Siemens actuators are SUA21\SQS65\SSC85\ SAX61\SKD62\SKB62\SKC62, etc.
Valve body:
 The executor that regulates the flow of medium is matched with the executor to form an electric regulating valve.  Siemens valves are divided into: copper valves, cast iron valves, ductile iron valves, cast steel valves;  According to the connection mode, it can be divided into: threaded connection and flange connection valves;  According to the medium used, it can be divided into water valve and steam valve.  Diameter DN10 ... DN150.(chenxuan  DN15-DN300)
Sensors:
 The temperature of the medium is measured in various types.  According to the installation position, it can be divided into immersion temperature sensor, binding temperature sensor, air duct temperature sensor, indoor temperature sensor, outdoor temperature sensor and other types.

Common Knowledge of SDCHENXUAN Temperature Control Valve Selection

 1. The valve material, flow capacity and actuator shutoff force shall be comprehensively considered according to the type of heat medium ( steam / hot water ), temperature, pressure parameters and operating conditions ( heat exchanger type, opening / closing system ).
 2, when used for steam flow control, generally refers to 98 % dryness of saturated steam.  If it is superheated steam, due to the change of steam adiabatic index k and the corresponding change of fluid viscosity coefficient, it is generally necessary to recalculate and check.
 3. The medium flow rate has a square root relationship with the differential pressure before and after the valve.  Excessive pressure difference not only produces noise, but also has cavitation effect on valve body, affecting service life. The light ones are not tightly sealed, and the heavy ones may explode, causing casualties and other major accidents.
 4. Excellent temperature regulation curve is the guarantee to realize temperature control effect.  Except for the special requirements of the fast thermal system, the valve shall be of equal percentage or parabolic type as far as possible.
 Equal percentage: q / qmax = r ( l / lmax - 1 )
 Parabolic: Q/Qmax=1/[1+ ( r - 1 under radical ) l / lmax ] 2
 5. Electric temperature control valve shall not be used as stop valve for a long time.  Please shut down when stopping the machine.
 6. The two-way valve must not be used as a three-way valve by removing the blind plate on the valve base.
 7. When using equipment produced by a third party to match Siemens products, attention should be paid to meeting safety requirements.
 8. The temperature control valve cannot use a direct water supply system and must be circulated. If it is an instant heat exchanger, a heat storage tank must be added.
 9. When working in domestic hot water, please distinguish between 24 - hour hot water supply and regular hot water supply.

ABOUT US:
Cryogenic Extended Bonnet Globe Valve 2 Inch ANSI 150
Cryogenic Extended Bonnet Globe Valve 2 Inch ANSI 150
Cryogenic Extended Bonnet Globe Valve 2 Inch ANSI 150
Cryogenic Extended Bonnet Globe Valve 2 Inch ANSI 150