4000- 10000W DC to AC Solar Power Inverter with UPS& MPPT Solar Charger

China 4000-10000W DC to AC Solar Power Inverter with UPS& MPPT Solar Charger, Find details about China Inverter, Solar Controller from 4000-10000W DC to AC Solar Power Inverter with UPS& MPPT Solar Charger

Model NO.
GS-4000W
Power Source
Solar Power
Circuit Topologies
Full-Bridge Type
Nature of Wave String
Sine Wave Inverter
Design
Low Frequency Pure Sine Wave
Outlook
Horizontal Type
Clolor
Black& White
Frequency
50/60 Adjustable
Voltage
110/120/130V&220/230/240V
Max Current
70A
Charging Mode
3 State Charging
Display
LCD and LED Optional
Remote Control
Yes
Customized
Yes
Trademark
ZLPOWER
Transport Package
Carton/Wooden Case
Specification
CE
Origin
Shenzhen
HS Code
8504403090
Model NO.
GS-4000W
Power Source
Solar Power
Circuit Topologies
Full-Bridge Type
Nature of Wave String
Sine Wave Inverter
Design
Low Frequency Pure Sine Wave
Outlook
Horizontal Type
Clolor
Black& White
Frequency
50/60 Adjustable
Voltage
110/120/130V&220/230/240V
Max Current
70A
Charging Mode
3 State Charging
Display
LCD and LED Optional
Remote Control
Yes
Customized
Yes
Trademark
ZLPOWER
Transport Package
Carton/Wooden Case
Specification
CE
Origin
Shenzhen
HS Code
8504403090
Solar Energy 6000W 48V DC to 110V/220V AC Pure Sine Wave Power Inverter
4000-10000W DC to AC Solar Power Inverter with UPS& MPPT Solar Charger
4000-10000W DC to AC Solar Power Inverter with UPS& MPPT Solar Charger
4000-10000W DC to AC Solar Power Inverter with UPS& MPPT Solar Charger
4000-10000W DC to AC Solar Power Inverter with UPS& MPPT Solar Charger

1.GS Series AC/Solar charging off grid hybrid inverter. 
2. LED/LCD display, Enhanced functions setting via LCD, Man-machine intelligent design.
3. Built-in 40A/60A optional MPPT solar charger controller.
4. LCD shows the solar capacity.
5. 5 stages adjustable AC charging current. AC charging also can be closed.
6. AC/DC priority modes can be set.
7. Generator restart signal. (Dry contact)
8. 3 times peak power. Strong loading capacity.
9. Overload, output short-circuit protection. 
 
MODEL
(GS Series)
HV/LV Model
HV Model(4-10KW)  LV Model(4-6KW)
Line Mode Specifications:
Input VoltageInput Voltage WaveformSinusoidal (utility or generator)
Nominal Input VoltageLV 120VacHV 230Vac
Low Line DisconnectNormal:85Vac±4% Wide:80Vac±4%Normal:184Vac±4% Wide:135Vac±4%
Low Line Re-connectNormal:95Vac±4% Wide:85Vac±4%Normal:194Vac±4% Wide:145Vac±4%
High Line DisconnectNormal:136Vac±4% Wide:140Vac±4%Normal:263Vac±4% Wide:263Vac±4%
High Line Re-connectNormal:131Vac±4% Wide:135Vac±4%Normal:253Vac±4% Wide:253Vac±4%
Max AC Input Voltage150Vrms270Vrms
Input FrequencyNominal Input Frequency50Hz/ 60Hz (Auto detection)
Low Line Frequency Re-connect51+0.3Hz for 60Hz;
41+0.3Hz for 50Hz;
Low Line Frequency Disconnect50+0.3Hz for 60Hz;
40+0.3Hz for 50Hz;
High Line Frequency Re-connect64+0.3Hz for 60Hz;
54+0.3Hz for 50Hz;
High Line Frequency Disconnect65+0.3Hz for 60Hz;
55+0.3Hz for 50Hz;
main functionsOutput Voltage WaveformAs same as Input Waveform
Over-Load Protection (SMPS load)Air switch
Output Short Circuit ProtectionAir switch
Max Bypass Overload Current40A/50A/80A
Battery Invert Mode Specifications:
AC outputOutput Voltage WaveformSine wave
Rated Output Power (KW)LV:4KW/5KW/6KWHV: 4KW/5KW/
6KW/7KW/8KW/10KW
Power Factor0.9~1.0
Nominal Output Voltage (V)LV:120Vac ±10%rmsHV:230Vac ±10%rms
Nominal Output Frequency (Hz)60Hz ± 0.3Hz
50Hz ± 0.3Hz
DC VoltageNominal DC Input Voltage24VDC/48VDC
DC Voltage range20-31.0Vdc for 24VDC
40-62.0Vdc for 48VDC
Low Battery Alarm21.0Vdc ± 0.6Vdc for 24V battery
42.0Vdc ± 1.2Vdc for 48V battery
Low DC input Shut-down20.0vdc± 0.6Vdc for 24V battery
40.0Vdc ± 1.2Vdc for 48V battery
High DC input Alarm & Fault32Vdc ± 0.6Vdc for 24V battery
64Vdc ± 1.2Vdc for 48V battery
High DC input Recovery31.0Vdc ± 0.6Vdc for 24V battery
62.0Vdc ± 1.2Vdc for 48V battery
AC ChargerNominal Charge Current35A/50A/70A (5 stages adjustable charging current)
Charge Current Regulation± 5Adc
Over Charge ProtectionBat.V>=31.0VDC for 24V battery
Bat.V>=62.0VDC for 48V battery
beeps 0.5s every 1s & fault after 60s
AlgorithmThree stage:  Boost CC (constant current stage) → Boost CV (constant voltage stage) → Float (constant voltage stage)
Solar chargerRated Charge Current40A60A
Rated charge battery Voltage type24V/48V24V
Max.PV open circuit array voltage24V for 55Vdc
48V for 110Vdc
Charger modeMPPT
PV Low Voltage Re-connectPV>=Bat.V=3V
PV Low Voltage DisconnectPV<=Bat.V
Efficiency>=97%
EfficiencyEfficiency (Battery Mode)>=85%
Efficiency (Line Mode)>98%
Transfer TimeAc to Dc20ms (Max)
Dc to Ac15ms (Max)
System parameterOver-Load Protection110% <load<150%, beeps 0.5s every 1s, and Fault after 60s off the output, Load>150%, beeps 0.5s every 1s, and Fault after 20s.
Output Short Circuit ProtectionCurrent limit (Fault after 10s)
Surge rating (10s)1:3 (VA)
Power saverLoad <=25W (Enabled on "P/S auto" setting of Remote control)
ProtectionsLow battery, over charging, over load , over temp.
IndicatorsLED+LCD Display
General SpecificationsOperating Temperature Range0°C to 40°C
Storage temperature-15ºC ~60ºC
Operation humidity5% to 95%(non-condensing)
Audible Noise60dB max
CoolingForced air, variable speed fan
Dimension(L*W*H)4KW5KW6KW7KW8KW10KW
530*400*190mm590*420*195mm
Net weight(Kg)30.035.538.541.548.055.0