China R410A DC Inverter Floor & ceiling Air Air Conditioner Heat Pump, Find details and Price about China Floor Air Conditioning, Floor Ceiling Air Conditioner from R410A DC Inverter Floor & ceiling Air Air Conditioner Heat Pump
Model | UCHA-12FDC | UCHA-18FDC | UCHA-24FDC | UCHA-36FDC | UCHA-48FDC | UCHA-60FDC | ||
Power supply | Ph-V-Hz | 1, 230V, 60Hz | 1, 230V, 60Hz | 1, 230V, 60Hz | 1, 230V, 60Hz | 1, 230V, 60Hz | ||
Cooling | Capacity | BTU | 119400(3400-13300) | 17000(7840-19700) | 23200(12690-29000) | 10400(5000-12000) | 13800(6000-14200) | 17000(6500-18500) |
Input | W | 960(270-1580) | 1440(750-2200) | 2131(1300-3450) | 3313(2100-4350) | 4647(2500-4950) | 5762(2600-6500) | |
Rated current | A | 4.36(1.5~6.85) | 6.55(3.4~10.0) | 9.2(6.0~16.0) | 14.7(9.5-18.9) | 20.2(11.6-22.5) | 25.05(12.1-28.9) | |
EER | BTU/W | 12.41 | 11.83 | 10.88 | 10.71 | 10.13 | 10.06 | |
Heating | Capacity | BTU | 12960(3680-15350) | 18420(8180-21500) | 24500(13640-31000) | 10700(6000-12000) | 14300(6300-14400) | 17600(8100-19100) |
Input | W | 1172(260-1680) | 1700(675-2280) | 2320(1310-3600) | 3507(2400-4600) | 4912(2050-5600) | 6170(2780-6800) | |
Rated current | A | 5.1(1.5-7.32) | 7.4(3.5-11.2) | 9.7(6.1-16.3) | 15.5(10.4-20.5) | 21.3(8.9-24.8) | 26.82(12.9-29.5) | |
COP | W/W | 3.24 | 3.18 | 3.1 | 3.05 | 2.91 | 2.85 | |
SEER | BTU·h/W·h | 18.56 | 17.91 | 17.81 | 17.19 | 16.68 | 16.31 | |
Indoor air flow | CFM | 411 | 500 | 576 | 676 | 811 | 970 | |
Indoor unit | Dimension (W*H*D) | Inch | 37.1×26.2×9.5 | 37.1×26.2×9.5 | 52×26.2×9.5 | 52×26.2×9.5 | 66.9×26.2×9.5 | 66.9×26.2×9.5 |
Packing (W*H*D) | Inch | 38.8×29.6×12.3 | 38.8×29.6×12.3 | 53.6×29.8×12.1 | 53.6×29.8×12.1 | 69×30×12.3 | 69×30×12.3 | |
Net/Gross weight | Ibs | 85.5/92.5 | 97.8/101.5 | 106.8/120.8 | 113.6/117.9 | 126.0/131.0 | 139.5/146.5 | |
Outdoor unit | Dimension (W*H*D) | Inch | 31.2X21.5X9.8 | 33X23.7X11.1 | 32.3X27.7X12.1 | 34.3X31.2X14 | 49.1X32.4X12.1 | 49.5X36.3X15.2 |
Packing (W*H*D) | Inch | 34.7X25.5X14 | 38.2X25X15.6 | 37.8X29.1X16 | 40X32.8X17.7 | 49.5X37.8X16 | 50X41.7X19.1 | |
Net/Gross weight | Ibs | 94.5/101.2 | 117.0/121.5 | 148.5/152.8 | 144.3/149.5 | 229.5/249.7 | 239.5/258.5 | |
Noise level | Indoor | dB(A) | 30-42 | 32-47 | 33-48 | 35-49 | 36-50 | 36-52 |
Outdoor | dB(A) | 48 | 53 | 55 | 57 | 59 | 59 | |
Dehumidification Capacity | L/H | 1.08 | 1.88 | 2.4 | 2.95 | 3.65 | 4.5 | |
MAX.Pipe Length | Ft | 32.81 | 32.81 | 49.21 | 49.21 | 65.62 | 82.02 | |
MAX.Height Difference | Ft | 26.25 | 26.25 | 32.81 | 32.81 | 49.21 | 49.21 | |
Pipe Size Liquid/Gas | Inch | 1/4 - 1/2 | 1/4 - 1/2 | 3/4 - 5/8 | 3/4 - 5/8 | 1/2 - 3/4 | 1/2 - 3/4 | |
Refrigerant | R410a | R410a | R410a | R410a | R410a | R410a | ||
Design pressure | Psi | 600 | 600 | 600 | 600 | 600 | 600 | |
Operation temp | ºF | 62 - 88 | 62 - 88 | 62 - 88 | 62 - 88 | 62 - 88 | 62 - 88 | |
Ambient temp | ºF | -13 - 116 | -13 - 116 | -13 - 116 | -13 - 116 | -13 - 116 | -13 - 116 | |
Application area | Ft2 | 151-237 | 210-324 | 486-648 | 810-972 | 1080-1188 | 1188-1350 | |
Rated cooling test conditions:Outdoor dry bulb temperature/Wet bulb temperature95.0ºF\75.0ºF Indoor dry bulb temperature/Wet bulb temperature80.0ºF\67.0ºF | ||||||||
Rated heating test conditions:Outdoor dry bulb temperature/Wet bulb temperature47.0ºF\43.0ºF Indoor dry bulb temperature/Wet bulb temperature70.0ºF\60.0ºF | ||||||||
The difference between the fixed-frequency and frequency of:: | ||||||||
Fixed-frequency machine: the outdoor unit operating ambient temperature range is relatively narrow (19-109 ºF) and can not adjust the size of the cooling / heating capacity of the indoor temperature changes, the machine open between stops, the indoor temperature fluctuations, feels suddenly cold suddenly hot. | ||||||||
Frequency Machine: the outdoor unit operating ambient temperature range is wide (-13-126 ºF) and can change depending on the temperature and adjust the size of the room cooling / heating capacity, the indoor temperature a smooth transition, the temperature fluctuation is small, automatic climate control, power consumption energy-saving effect is remarkable. | ||||||||