48000BTU DC Inverter Ducted Air Conditioner Heat Pump

China 48000BTU DC Inverter Ducted Air Conditioner Heat Pump, Find details and Price about China Duct Air Conditioner, Ducted Air Conditioning from 48000BTU DC Inverter Ducted Air Conditioner Heat Pump

Model NO.
UCHA-48DDC
Cooling/Heating
Cooling/Heating
Power Source
Electrical
Power Type
DC
Condition
New
Eer
10.79
Cop
3.21
Seer
16.02
Hspf
9.7
Air Volume (H/M/L
1190/1060/930 Cfm
Static Pressure
130 PA
Trademark
VKIN/UTL
Transport Package
Carton
Specification
41.4X15.6X21.7 in
Origin
China
HS Code
8415812001
Model NO.
UCHA-48DDC
Cooling/Heating
Cooling/Heating
Power Source
Electrical
Power Type
DC
Condition
New
Eer
10.79
Cop
3.21
Seer
16.02
Hspf
9.7
Air Volume (H/M/L
1190/1060/930 Cfm
Static Pressure
130 PA
Trademark
VKIN/UTL
Transport Package
Carton
Specification
41.4X15.6X21.7 in
Origin
China
HS Code
8415812001
vkin dc inverter ducted air conditioner heat pump systems are a discreet and effective heating and cooling solution for your home. With vkin ducted air conditioners, perfectly temperature controlled air will flow through vents on the ceiling or on the wall, cooling your home in summer and heating it in winter.
Our ducted air conditioning systems are ideal for multiple room applications and can incorporate zone selection if required. Speak to an air conditioning specialist. Discuss your cooling and heating requirements with a UTL Air Conditioning Technology Co.,Ltd., your local air conditioning specialist.
48000BTU DC Inverter Ducted Air Conditioner Heat Pump48000BTU DC Inverter Ducted Air Conditioner Heat Pump
48000BTU DC Inverter Ducted Air Conditioner Heat Pump
48000BTU DC Inverter Ducted Air Conditioner Heat Pump
48000BTU DC Inverter Ducted Air Conditioner Heat Pump48000BTU DC Inverter Ducted Air Conditioner Heat Pump
ModelUCHA-24DDCUCHA-36DDCUCHA-48DDCUCHA-60DDC
Power supplyPh-V-Hz1, 230V ,60Hz
CoolingCapacityBTU24000(12280-27300)35600(17050-40940)47900(25580-53560)58500(27970-61410)
InputW2053(1100-3450)3254(1350-3800)4440(2050-5350)5550(2650-5900)
Rated currentA8.9(4.8~16.0)14.1(5.86-16.52)19.1(8.91-23.26)24.1(11.52-25.62)
EERBTU/W11.6910.9410.7910.54
HeatingCapacityBTU24900(13640-29000)37500(22170-41960)48800(26610-56630)60000(28650-64140)
InputW2140(1150-3600)3393(1420-3950)4450(2190-5510)5660(2780-6150)
Rated currentA9.18(5.0-16.36)15.11(6.17-17.17)20.33(9.52-23.94)25.89(12.08-26.73)
COPW/W3.413.243.213.11
SEERBTU·h/W·h17.7616.5216.0214.76
HSPFBTU·h/W·h10.510.29.79.7
Dehumidification Capacity in Cooling modeOutdoor ambient temperature: DB95ºF(35ºC)/WB75ºF(23.9ºC),RH 40%;Indoor ambient temperature: DB80ºF(26.7ºC)/WB67ºF(19.4ºC),RH 51%.L/h2.423.053.64.58
Dehumidification Capacity in dehumidification modeL/h1.251.52.12.6
Dehumidification Capacity in Cooling modeOutdoor ambient temperature: DB81ºF(27ºC)/WB75ºF(24ºC),RH 78%;Indoor ambient temperature: DB81ºF(27ºC)/WB75ºF(24ºC),RH 78%.L/h4.355.656.628.2
Dehumidification Capacity in dehumidification modeL/h3.33.94.555.6
air volume at the static pressure (H/M/L)Pa130Pa
CFM800/680/5601060/880/7001190/1060/9301706/1530/1350
Indoor Motor (H/M/L)W400/320/240500/380/280500/380/280700/580/450
Speed3-speed
Indoor unitDimension (W*H*D)Inch38.2X13.8X20.938.2X13.8X20.941.4X15.6X21.741.4X15.6X21.7
Packing   (W*H*D)Inch40.6X14.2X22.840.6X14.2X22.843.7X16.1X23.643.7X16.1X23.6
Net/Gross weightIbs94.8/101.4110.2/116.8116.8/123.5123.5/130.1
Noise levelIndoordB(A)36-4740-4741-5243-54
Pipe Size Liquid/GasInch3/8 - 5/83/8- 5/81/2 -  3/41/2 - 3/4
Refrigerant R410aR410aR410aR410a
Design pressurePsi600600600600
Outdoor unitDimension (W*H*D)Inch34.3X31.2X1434.3X31.2X1449.5X36.3X15.249.5X36.3X15.2
Packing   (W*H*D)Inch40X32.8X17.840X32.8X17.850X41.7X19.150X41.7X19.1
Net/Gross weightIbs128.2/132.7128.2/132.7229.5/249.7229.5/249.7
Noise levelOutdoordB(A)40-4841-5046-5347-55
MAX.Pipe LengthFt49.2149.2165.6282.02
MAX.Height DifferenceFt32.8132.8149.2149.21
Pipe Size Liquid/GasInch3/8 - 5/83/8- 5/81/2 -  3/41/2 - 3/4
Refrigerant R410aR410aR410aR410a
Design pressurePsi600600600600
Operation tempºF62  -  8862  -  8862  -  8862  -  88
Ambient tempºF-13 - 116-13 - 116-13 - 116-13 - 116
Application areaFt2324-432432-540752-972864-1080
Cooling test condition: Outdoor Dry/Wet bulb temp. 95.0ºF\75.0ºF,  Intdoor Dry/Wet bulb temp. 80.0ºF\67.0ºF
Heating test condition: Outdoor Dry/Wet bulb temp. 47.0ºF\43.0ºF,  Intdoor Dry/Wet bulb temp. 70.0ºF\60.0ºF
48000BTU DC Inverter Ducted Air Conditioner Heat Pump
Welcome to VKIN

VKIN is one of the largest manufacturers of DC inverter Air conditiner,DC inverter Swimming Pool Heat Pumps,DC inverter Heat Pump Water Heaters in China.  VKIN's vision is "to be a young company forever, with the human wisdom to achieve the harmonious development of man and nature, TRUST ALWAYS."

VKIN has more than 100 national patents covering air conditioning, heat pump and heat pump technology, building a complete heat pump industry chain. In addition, VKIN has developed hardware and software for intelligent device control that allows customers to customize VKIN devices to their individual needs. VKIN provides comprehensive energy-saving overall solutions and products for medium and high-end users both at home and abroad, including air conditioners, constant temperature and humidity machines, swimming pool heat pumps, room heating and heat pumps, industrial heat pumps and the like.

As an international company, VKIN attaches great importance to the high-end overseas markets. More than 90% of its products are exported to North America, Europe, North America, the Middle East, Australia and other developed regions.