Hot Water Heat Pump Automatic Defrosting

China Hot Water Heat Pump Automatic Defrosting, Find details about China Heat Pump, Standard Climate Range Pool Heat Pump from Hot Water Heat Pump Automatic Defrosting

Model NO.
LAS18-KP/LAS21-KP
Model NO.
LAS18-KP/LAS21-KP

NORMAL TEMPERATURE SWIMMING POOL HEAT PUMP

LASWIM normal temperature commercial swimming pool heat pump is designed with titanium heat exchanger, can effectively resist the corrosion of chloride ion in pool water, This series heat pump is a reliable and energy-saving solution for pool in hotels, SPA, water parks, gyms, competition pool, etc.

 

Features:

1.Intelligent control for constant pool water temperature (max 40ºC)

2.Wide working air temperature range: -5ºC to 45ºC

3.Anti-corrosion titanium in PVC heat exchanger for durable use

4.Multiple protections for safe operation and long service life.

5.The housing adopts high-quality galvanized sheet, with strong corrosion resistance.

6.Powerful centralized control and remote control is available for convenient operation and maintenance.

7.Automatic and forced defrosting function.

 

Hot Water Heat Pump Automatic Defrosting

Technical Parameters

Model LAS18-KP  LAS21-KPLAS35-KPLAS42-KPLAS52-KPLAS70-KPLAS85-KPLAS105-KP
Standard heating Heating capacitykW20.124.140.248.256.380.4696.4112.6
conditionCOP5.585.585.585.585.585.585.585.58
Low temperature heating conditionHeatingkW15.318.430.636.842.861.273.642.8
capacity
COP4.24.24.24.24.24.24.24.2
Cooling   conditionCoolinkW13.416.126.832.237.553.664.437.5
 capacity
EER3.23.23.23.23.23.23.23.2
Advised pool volume20-6030-8060-12070-16080-180140-280170-350200-420
Power supply...380V/3N/50Hz
Rated input powerkW3.64.37.28.610.114.417.220.2
Rated input currentA6.17.312.214.617.124.429.234.2
Max. Input powerkW5.97.111.814.216.523.628.433
Max. Input currentA9.911.919.823.827.739.647.655.4
Max. water   temperatureºC40
Applicable ambient   temperatureºC-5~43
Heat exhangerTitanium in PVC (The material in contact with water is titaium)
Max. pressure   (Refrigerant side)MPa2.8/4.2
Refrigerant R22/R410A
Noise leveldB(A)≤63≤63≤64≤64≤65≤66≤67≤68
Water inlet/outlet sizemm4040505050505050
Circulating Water flow ratem³/h4.35.28.610.412.117.320.724.2
Water pressure dropkPa4047485050515350
Net weightKg110165280320420560650760
Net dimensionmm750/750/1050750/750/10501450/725/10501450/705/13501450/705/13502250/1035/12002250/1035/12002250/1035/1200


Remark:

  1. Standard heating condition: 20ºC DB,15ºC WB, inlet water temperature 26ºC;

  2. Low temperature heating condition: 7ºC DB, 6ºC WB, inlet water temperature 26ºC;

  3. Cooling condition: 35ºC DB, 27ºC WB, inlet water temperature 28ºC;

  4. Due to the continuous improvement of products, the actual data will be subject to change without prior notice, please refer to the nameplate.