Mobile X-ray Radiography Medical Diagnostic Machine/Equipment 50mA (PLX102)

China Mobile X-ray Radiography Medical Diagnostic Machine/Equipment 50mA (PLX102), Find details about China X-ray Machine, Xray Machine from Mobile X-ray Radiography Medical Diagnostic Machine/Equipment 50mA (PLX102)

Model NO.
PLX102
Max Mas
50mA
Exposure Time
0.1~6.3s
Voltage
40~90kv
Power Supply
110/220V 50/60Hz
Warranty
12 Months
Lead Time
Within 7 Working Days After Receiving Your Payment
Trademark
PIOWAY
Transport Package
Wooden Case
Specification
CE, TUV, ISO9001, 13485
Origin
China
Model NO.
PLX102
Max Mas
50mA
Exposure Time
0.1~6.3s
Voltage
40~90kv
Power Supply
110/220V 50/60Hz
Warranty
12 Months
Lead Time
Within 7 Working Days After Receiving Your Payment
Trademark
PIOWAY
Transport Package
Wooden Case
Specification
CE, TUV, ISO9001, 13485
Origin
China
Mobile X-ray Radiography Medical Diagnostic Machine/Equipment 50mA (PLX102)

Mobile X-ray Radiography Medical Diagnostic Machine/Equipment 50mA (PLX102)


Features
1. Using ergonomic design, the structure is of compact appearance, convenient operation.
2. It adopts high pressure-resistant electrical tube with enough kV and mA, so the
definition and contrast of the machine are good.
3. With combined X-ray generator, the tube and rocker can move up and down freely. So
the patient can take photography in a wider range of direction.
4. Because of symmetrical adjustable beam limiting device with light source, the x-ray
beam can be adjusted according to demands.
5. X-ray generator is matched with protective stereotype inside, and 10 meters wireless
remote control exposure is adopted, so it causes less hurt to the operators and
environment.
6. The current has three gears (15mA, 30mA, 50mA), different current can be selected
according to different photography requirements, thus using range of machine is wider.
7. Anti-electric shock, anti scattering and full-wave rectifier
8. The electric performance is stable and reliable. Multi-protections are adopted to prevent
over-voltage, over-current and output overload etc., so it's safer.
9. Telescopic vertical rotating angle is larger than 60°.

Usage
The machine is mobile X-ray radiography medical diagnostic equipment. It can be used in
wards, operation rooms and emergency rooms etc., and it can satisfy the radiography
requirements of human body such as head, chest and limbs. 


Specifications
Power Output3KW
X-Ray TubeFixed anode
Commute MethodFull wave commutation
Tube Voltage40~90KV
Tube Current50~90KV 15mA
50~90KV 30mA
40~80KV 50mA
Exposure Time50~90KV 15mA 0.1~6.3s
50~90KV 30mA 0.1~6.3s
40~80KV 50mA 0.1~1.5s
Power Supply220V/50Hz, 110V/60Hz
Operation MethodWire /Wireless control

Detailed Images
Mobile X-ray Radiography Medical Diagnostic Machine/Equipment 50mA (PLX102)
Other Models
Mobile X-ray Radiography Medical Diagnostic Machine/Equipment 50mA (PLX102)

Contact Us