HPLC High Performance Liquid Chromatography
![HPLC High Performance Liquid Chromatography Price](//image.made-in-china.com/226f3j00MnHQDthEVzqI/HPLC-High-Performance-Liquid-Chromatography-Price.webp)
HPLC High Performance Liquid Chromatography is updated from P230H HPLC System. It's the higher and more reliable quality product with samples analysis.
System Configuration
- Isocratic system
- High-pressure binary gradient system
- Quaternary low-pressure gradient system
- ELITE-AAK/AAP amino acid analytical system
Characteristics
1) Classic short stroke,serial pitsons,and multi-stage flow correction ensuring pump performance.
2) Concave surface holographic grating and intelligent power supply for deuterium lamp steadily improving detector functioning.
3) Self-development PID control measure bringing true the accuracy of column oven temperature to 0.1ºC.
4) The brand-new S3100 auto-sampler capable of greatly improving instrument automaticity and matching with a variety of HPLC systems.
5) Application of optoelectronic isolation and EMI protection ensuring stable communication.
6) All-round upgraded Chromsoft workstation that is operator-friendly and promotes customer experience.
Configuration Table
1 | P3100 High Pressure Constant Flow Pump | 1) Flow rate range: 0.001-10.000 mL/min, in 0.001 mL increments 2) Flow accuracy: ≤±0.2% (1.00ml/min, H2O,R.T.,8.5MPa) 3) Flow precision: RSD≤0.06% (1.00ml/min, H2O,R.T.,8.5MPa) 4) Maximum pressure: 45 MPa 5) Pressure accuracy: ≤±3.0% 6) Pressure pulsation: ≤0.1 MPa |
2 | UV3100 UV/VIS Detector | - Wavelength range: 190-700 nm
- Wavelength repeatability: ≤0.1 nm
- Wavelength accuracy: ≤±1.0 nm
- Bandwidth: 8nm
- Response time: 0.0 s-5 s
- Baseline noise: ≤±0.5×10-5 AU
- Drift: ≤1.0×10-4 AU/h (empty cell, 254 nm, 60 min)
- Path length: 10 mm(analytical cell)
- Light source: Deuterium Lamp
|
3 | Chromsoft Chromatographic Data-processing Workstation | - Internal and external standard calculation methods
- Automatically displays, prints, exports and starts other programs after the completion of a measurement.
- Comply with the requirements of the 21 CFR Part 11 directive of the FDA.
|
4 | GD-3100 System Kits | - Containing required tubing, fittings, wreches and cables for system.
- 7725i manual injector
- TD-1-15 static mixer
- Supersil ODS2 5μm ID4.6*200mm
|
5 | S3100 Autosampler (optional) | - Inject volum range: 0-100 μL (standard)
- Precision: RSD <0.3%
- linearity: >0.999
- Sample residual: <0.01%
- Number of sample plates: Two of 60 position 2-mL vial plates
- Syringe: 500 μL
|
6 | O3100 Colunm Oven | - Column capacity: Three columns, up to 10mm internal diameter, up to 250mm length with guard column
- Temperature range: Ambient+5.0 to 80ºC, settable in 0.1ºC increments
- Temperature accuracy: ≤±0.5ºC
- Temperature stability: ≤±0.1ºC
|
7 | Pretreatment (optional) | - Ultrasonic Bench Top Cleaner
- Φ13mm/Φ25mm Nylon (organic) (100/pk)
- Φ13mm/Φ25mm Cellulose (aqueous) (100/pk)
- Diaphragm Vacuum Pump
- Φ50mm Solvent Filter (Include Nylon and Cellulose, 100/pk)
|
![HPLC High Performance Liquid Chromatography Price](//image.made-in-china.com/226f3j00CnLEDRiPOrqH/HPLC-High-Performance-Liquid-Chromatography-Price.webp)
Success Case A Transformer Oil Lab from Philippines Ordered 8 Sets Equipment
![HPLC High Performance Liquid Chromatography Price](//image.made-in-china.com/226f3j00ByPaHIiGOrqD/HPLC-High-Performance-Liquid-Chromatography-Price.webp)
A Transformer Oil Lab in Manila,Philippines who placed an order with us on July 11,2019. Total 8 equipment. which includes:
- GDYJ-502A 80KV Transformer Oil BDV Tester,
- GDGY Transformer Oil Tan Delta Tester,
- GC-7890-DL Transformer Oil Dissolved Gas Analyzer
- GD-2100 Karl Fischer Moisture Titrator(Coulometric method)
- GD-6541A Automatic Interfacial Tension Tester
- GD-752N UV Vis Spectrophotometer
- GD-3100 Gradient HPLC System
- GD-105 Automatic Acid Number Tester (ASTM D974)
We will provide a training in their lab.