Ms-8100 10.1" Multi-Parameter Patient Monitor

China Ms-8100 10.1" Multi-Parameter Patient Monitor, Find details about China 12" Patient Monitor, Multi Parameter Patient Monitor from Ms-8100 10.1" Multi-Parameter Patient Monitor

Model NO.
MS-8100
Trademark
customized
Origin
China
HS Code
9018193010
Model NO.
MS-8100
Trademark
customized
Origin
China
HS Code
9018193010
MS-8100 Multi-Parameter Patient Monitor

Features
  1. 10.1 inch high resolution color TFT display
  2. Lightweight and portable design suitable for ambulance, emergency transport
  3. Three Working Modes: Monitoring, Surgery and Diagnosis.
  4. Simple and friendly operating display interface.
  5. Multi-display modes suitable for different applications:
Standard Interface, Large font, ECG Standard Full Display, OXY , Trend Table, BP Trend.
  1. Built-in high capacity battery up to 2 hours of continuous work

Technique Specification
ECG
  1. Lead Mode: 5 Leads (I, II, III, AVR, AVL,AVF, V)
  2. Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV
  3. Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
Resolution: 1 BPM
Accuracy: ±1%
Sensitivity >200 uV(Peak to peak)
  1. ST measurement range: -2.0 ~ +2.0 mV
Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
Other Range: unspecified
  1. Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
  2. Bandwidth:
    1. Diagnostic: 0.05~130 Hz
    2. Monitor: 0.5~40 Hz
    3. Surgery: 1~20 Hz
                       
SPO2
  1. Measuring Range: 0 ~ 100 %
  2. Resolution: 1%
  3. Accuracy: 70% ~ 100% (±2 %)
  4. Pulse Rate: 20-250 BPM
  5. Resolution: 1 BPM
  6. Accuracy: ±3 BPM


NIBP
  1. Method: Oscillometry
  2. Measure mode: Manual, Auto, STAT
  3. Unit: mmHg, kPa
  4. Measure and alarm range:        
    1. Adult Mode
          1. SYS     40 ~ 280 mmHg
          2. DIA       10 ~ 225 mmHg
          3. MEAN 20 ~ 240 mmHg
    2. Pediatric Mode
          1. SYS  40 ~ 220 mmHg
          2. DIA  10 ~ 160 mmHg
          3. MEAN  20 ~ 170 mmHg
    3. Neonatal Mode
          1. SYS     40 ~ 135 mmHg
          2. DIA       10 ~ 100 mmHg
          3. MEAN  20 ~ 110 mmHg
  5. Resolution: 1mmHg
  6. Accuracy: ±5mmHg

RESP
  1. Method: Impedance between RA-LL or RALA
  2. Measurement Range:
Adult: 10 ~ 120 BrPM
Neonatal / Pediatric: 7 ~ 150 BrPM
  1. Resolution: 1 BrPM
  2. Accuracy: ±2 BrPM

TEMP
  1. Measure and Alarm Range: 0 ~ 50 °C
  2. Resolution: 0.1°C
  3. Accuracy: ±0.1°C

Standard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR

Optional Parameters:
  1. Central monitoring system
  2. Dual IBP
  3. Etco2
  4. 12-lead ECG
  5. Nellcor SpO2
  6. Sun Tech NIBP

Standard Configuration:
No.ItemQty
1Main Unit1
25-lead ECG cable1
3Disposable ECG Electrode5
4Adult Spo2 probe1
5Adult NIBP cuff1
6NIBP extension tube1
7Temperature probe1
8Power Cable1
9User Manual1
10Fuse2

Packing:
  1. Single package size: 34.7*20.7*27.7cm
  2. Single gross weight: 2.8 KG
  3. 6 unit per carton, package size: 65*36.2*59cm, total gross weight 18 KG