New R744 (CO2) DC Inverter Monobloc Air Source Heat Pump ERP a+++ 9kw to 20kw with Carel Controller

China New R744 (CO2) DC Inverter Monobloc Air Source Heat Pump ERP a+++ 9kw to 20kw with Carel Controller, Find details and Price about China R744 Heat Pump, CO2 Heat Pump from New R744 (CO2) DC Inverter Monobloc Air Source Heat Pump ERP a+++ 9kw to 20kw with Carel Controller

Certification
CE, ISO9001, CCC, CB, RoHS
Trademark
ZHONGNAN
Transport Package
Wooden Box
Specification
30KW
Origin
China
HS Code
8415812000
Certification
CE, ISO9001, CCC, CB, RoHS
Trademark
ZHONGNAN
Transport Package
Wooden Box
Specification
30KW
Origin
China
HS Code
8415812000

1. This is real CO2 heat pump water heater, with Inverter technology.

2. CO2 is next generantion refrigerant, non-flammable, non-toxic,natural

3. CO2 heat pump can work on -25ºC , and its COP is high , system no need the Aux-heater even in low temp area

4. Our system can make water outcome in 85ºC , suitable for special requirements of hot water ,EVI or any existing heat pump can not do this.

5. Our system is INVETER units, compressor and motors are INVERTER, which can save more energy

The advantages of CO2 as a refrigerant
  • Climate-neutral environmentally friendly refrigerant R744 (CO2)
  • Without environmentally hazardous decomposition products
  • No additional contribution to the greenhouse effect (GWP = 1)
  • Does not contribute to the ozone depletion (ODP = 0)
  • No disposal and recycling requirements
  • No availability constraints
  • Low security requirements - Safety Group A1
  • Non-toxic, non-flammable, thermally stable, compatible with other materials
INVERTER CO2(R744) heat pump specification
Bitmap
Model
LYD7ZW(40L-260L)8ZW14ZW25ZW40ZW50ZW75ZW120ZW
Standard temperature conditionHeating CapacitykW6.87.813.624405175.5125.4
Hot water capacityL/H129.9149259.845876497414422396
Heating power inputkW1.511.735.3911.316.726.6
COPW/W4.54.584.64.54.44.54.54.7
Low temperature conditionHeating CapacitykW5.8712.1203545.66495
Hot water capacityL/H97.7118203.933759076810791602
Heating power inputkW1.471.7359.41216.824.3
COPW/W3.94.14.143.73.83.83.9
Ultra-Low temperature conditionHeating CapacitykW5.36.511.2142835.749.178
Hot water capacityL/H89.3109188.82364726018261315
Heating power inputkW1.461.712.94.810.112.316.826
COPW/W3.623.83.92.92.82.92.93
Power supplyV/Ph/Hz         
Heating type Direct
Rated output water temperatureºC45
Maximum output water temperatureºC95
Work ambient temperatureºC(-)25-43
CompressorTypePanasonicTorin(Italy)
Defrosting type  Bypass
Water connection pipe sizemmDN15DN20DN25
Water side heat exchangerTypeTube-Tube type
Air side heat exchangerTypeHigh efficiency copper tube(Interior Screw) nested in aluminium fin
RefrigerantTypeR744/CO2
DimensionsLengthmm52091091012801803180320462468
Widthmm52043043080083083011061368
Heightmm17001000100015002100210023002413
Unit noise level dB(A)4042454649505465
Net weight kg1321301813805256509801350
Inverter DCAC
Note:          
1.Standard temperature condition:Ambient temperature 20ºC,Water temperature: inlet 15ºC,outlet 60ºC    
2.Low temperature condition:Ambient temperature 7ºC,Water temperature: inlet 9ºC,outlet 60ºC     
3.Ultra-Low temperature condition: Ambient temperature -7ºC,Water temperature: inlet 9ºC,outlet 60ºC