4-20mA to RS485 Converter, Current to RS485 with Modbus

China 4-20mA to RS485 Converter, Current to RS485 with Modbus, Find details about China Signal Converter, Signal Conditioner from 4-20mA to RS485 Converter, Current to RS485 with Modbus

Model NO.
SY AD02 U(A)
Accuracy
0.05%
Weight
72g
Isolation Voltage
3000VDC
Export Market
Global
Trademark
SUNYUAN
Transport Package
Adam DIN Rail
Specification
ISO9001: 2008, CE, RoHS
Origin
Shenzhen
Model NO.
SY AD02 U(A)
Accuracy
0.05%
Weight
72g
Isolation Voltage
3000VDC
Export Market
Global
Trademark
SUNYUAN
Transport Package
Adam DIN Rail
Specification
ISO9001: 2008, CE, RoHS
Origin
Shenzhen
DC Current/Voltage (0-5V/4-20mA, etc) to RS485/RS232 A-D Converter with Temperature Detection

SY AD 02C General parameters:

(typical @ +25º C, Vs@24VDC)
Input: Voltage / Current
Accuracy: 0.05%
Put imbalanceIn: ± 0.1 uA/º C
Temperature Drift: ± 15 ppm/º C (± 30 ppm/º C, max)
Input load: 50Ω (4-20mA/0-20mA/0-± 20mA current input)
100Ω (0-10mA/0-± 10mA current input)
1KΩ (0-1mA/0-± 1mA current input)
>1MΩ (voltage input)
Band width: -3 dB 10 Hz
Switching rate: 10 Sps
Common mode restraint(CMR): 120 dB(1kΩ Source Imbalance @ 50/60 Hz)
Normal mode restraint(NMR): 60 dB (1kΩ Source Imbalance @ 50/60 Hz)
Temperature Measure Range: -55º C~+125º C, with inherent temperature resolution 0.5º C.
Input terminal protection: Over-voltage/over current protection
Communications: Protocol RS-485 or RS-232 ASCII character communication protocol and MODBUS RTU communication protocol
Baud rate(300, 600, 1200, 2400, 4800, 9600, 19200, 38400bps)software selectable
Address(00H~FFH)software selectable
Response Time: 100 ms max
Operation Power Supply: +8 ~ 50 VDC wide power supply range, internal anti-reverse & over-voltage protection
Watt consumption: < 1W
Operation Temperature: - 45 ~ +80º C
Operation Humidity: 10 ~ 90% (non-condensing)
Storage Temperature: - 45 ~ +80º C
Storage Humidity: 10 ~ 95% (non-condensing)
Isolation withstand voltage: Between input and output: 3KVDC, 1 minute, stray current 1mA
Output and power are common-ground.
Endure Impact Voltage: 3KVAC, 1.2/50us(peak value)
Dimensions: 120 mm x 70 mm x 30mm
Weight: Approximately 72g

Model selection:

SY AD 02C U(A) -

Input voltage or current signal
U1: 0-5V A1: 0-1mA
U2: 0-10V A2: 0-10mA
U3: 0-75mV A3: 0-20mA
U4: 0-2.5V A4: 4-20mA
U5: 0-± 5V A5: 0-± 1mA
U6: 0-± 10V A6: 0-± 10mA
U7: 0-± 100mV A7: 0-± 20mA
U8: Customized A8: Customized

Note: SY AD 02C can support RS232 and RS485 communication port, user can choose the communication port according the application environment. But at the same time, only one communication port can work, or will have interference.
E. G.:
1. SY AD 02C A4 Means 4-20ma signal output, and support one channel DS18B20 temperature signal input
2. SY AD 02C A7 Means 0-5V signal output, and support one channel DS18B20 temperature signal input
3. SY AD 02C U1 Means 0-± 5V signal output, and support one channel DS18B20 temperature signal input