Medical Ysx040-C Vet Digital Radiography X Ray

China Medical Ysx040-C Vet Digital Radiography X Ray, Find details about China Vet Digital Radiography X Ray, X-ray from Medical Ysx040-C Vet Digital Radiography X Ray

Model NO.
YSX040-C
Mas Adjustable Range
1mas-200mas
Tube Voltage Range
40~110kv
Tube Current Range
36~70mA
Focus
0.6/1.5mm
Voltage
220V±22V 50Hz/60Hz
Maximum Output Power
4kw
Frequency
≥40kHz
Exposure Time Adjustable Range
0.04s~3.2s
Trademark
ysenmed
Transport Package
Standard Export Wooden Case
Origin
China
Model NO.
YSX040-C
Mas Adjustable Range
1mas-200mas
Tube Voltage Range
40~110kv
Tube Current Range
36~70mA
Focus
0.6/1.5mm
Voltage
220V±22V 50Hz/60Hz
Maximum Output Power
4kw
Frequency
≥40kHz
Exposure Time Adjustable Range
0.04s~3.2s
Trademark
ysenmed
Transport Package
Standard Export Wooden Case
Origin
China

Medical YSX040-C Vet Digital Radiography X Ray
Model:YSX040-C



Medical Ysx040-C Vet Digital Radiography X Ray

 

1.Composition

Main ComponentsPartsQtyRemarkPackage Size (cm)Weight (kgs)
X-ray UnitsPortable high frequency x-ray unit1 set 65*50*5034
Toshiba X-ray tube1 set 
Collimator1 pc 
DR SystemDigital detector1 set 50*50*7040
DR image processing software1 set 
AuxiliariesSteel support1 setOptional116*80*3432
 
2. Application
The 4kW portable digital high frequency x-ray unit is mainly suitable for extremities check, especially for rescues or diagnosis in field operation sites, battlefields, stadiums, vet clinics, etc. 
3. Features
1)Toshiba x-ray tube
2) Simple & light structure;
3) 6-segment LED digital display;
4) Anatomical memories for 24 selection program;
5) Double-loop (analog & digital) high precision control mode;
6) High precision control in tube voltage & current;
7) Self-protection & auto-diagnosis available when malfunction occurs.
4. Specifications
ModelYSX040-C
Power supplyVoltage: AC220V± 10%, 50/60Hz ± 1Hz
Capacity: ≥5kVA;
Internal resistance: ≤0.5Ω
Maximum output powerP =110kV×36mA=4kW
Nominal output power100kV,40mA,0.1s,4kW
Frequency≥40kHz
kV adjustable range40kV~110kV, continuous regulation, stepping 1kV
mA adjustable range36mA~60mA
mAs adjustable range1mAs-190mAs,continuous regulation
Exposure time adjustable range0.04s~3.2s
Toshiba X ray tubeToshiba X ray tube
Focus: 0.5/1.6mm,
Thermal Capacity: 76kHU
Digital detectorLimit resolution: 3.9LP/mm;
A/D convert:14bit;
Pixel region: 264×325mm;
Pixel matrix: 2080×2560;
Anatomical program24 memory choices available
AccessoriesStandard: manual switch,cable
Optional: mobile steel support