Gas Eliminator Discharge The Gas (LPX)

China Gas Eliminator Discharge The Gas (LPX), Find details about China Gas, Air Release from Gas Eliminator Discharge The Gas (LPX)

Model NO.
LPX
Trademark
YINUO
Transport Package
Plwood Case
Origin
China
HS Code
90269000
Model NO.
LPX
Trademark
YINUO
Transport Package
Plwood Case
Origin
China
HS Code
90269000
1. Working Principle
The LPX utilizes the floating force of gas bubbles in the fluid to be measured. When flowing into the LPX from the inlet, the fluid containing gas bubbles will rush against the guiding tube mounted in the body and makes an eddy current.
By the effect of the above eddy current, small gas bubbles are collected into large ones. The bubbles which have become apart from the liquid will go upward and then flow out from the top of LPX.
2. Operation Guide
  1. In order to clean, overhaul and install more quickly, some LPX are designed into Quick Discharge type.
  2. The up-cover is the brace framework for installing the manual valve, gas auto-eliminator and tightening bolt. The hoop is used for connecting the up-cover and body of LPX. Unpack the tightening bolt to open the hoop so that take out the eliminator of gas to clean, overhaul or replace.
  3. LPX should be mounted in the pipeline or upstream the filter and flowmeter according to the arrow on the body. Before installing the LPX, please assure that all the parts of LPX are in good condition, there is no impurity and then clean out the gas in the LPX and pipe system.
  4. For environment protection, it is necessary to connect proper vent-pipe or oil exit pipe downstream the mechanism of gas auto-eliminator and the valve of manual gas eliminator to collect the gas and drainage. It is forbidden to discharge indoors the gas out of LPX. According to the special requirement, the hole of drainage can also be connected pipeline of steam or hot water. Before the halt of use, it is necessary to thaw the oil product by steam or hot water so that LPX can work well next time.
  5. As shown in Picture 4, for maximizing the performance of LPX, it is necessary to mount one counterbalance valve or set one elevatory pipe after the outlet of flowmeter so as to produce the back pressure of 0.015MPa~0.03MPa. The elevatory height is calculated as follows: H=2.2m×(ρ÷ρi)
Notes: H-elevatory height of pipe(m);
 ρ-density of water(1 g/cm3)
 ρi-density of measured medium(g/cm3

3. Main Technical Data
  1. a. Nominal Diameter: DN50~DN800
    b. Nominal Pressure: 1.6~4.0MPa
    c. Press Loss: 0.02MPa
    d. Fluid Temperature: 0ºC~+250ºC
    e. Viscosity range: 0.4~3000mPa·s
    f. Outline Dimension(Shown in following table)
     
    Nominal Diameter
    (mm)
    Nominal
    Pressure
    (MPa)
    FlangeInstall DimensionConnect LengthInstall
    Height
    Total
    Height
    Mesh No.Weight
    Bolt hole
    D1
    screwMBolt holeBoltLAH
    n2φdDn1Mkg
    501.6125418M163103M163202377052040
    2.5,4.0125418M163103M164045
    801.6160818M163353M164202608302065
    2.5,4.0160818M163353M164070
    1001.6180818M163353M20520315106020120
    2.5,4.0190823M203353M2020125
    1501.6240823M205203M20720500120020180
    2.5,4.0250825M225203M2020188
    2001.62951223M206343M20800538153010480
    2.53101225M226343M2010490
    4.03201230M276343M2020505
    2501.63551225M226583M2010005801620101300
    2.53701230M276583M20101330
    4.03851234M306583M20201375
    3001.64101225M226703M22110010702130101750
    2.54301630M276703M30101800
    4.04501634M306703M30201880
    3501.64701625M227503M30 
    1300
    11002360102000
    2.54901634M307503M30202150
    4001.65251630M278003M30160011002400102480
    2.55501634M308003M30102580
    5001.66502034M309503M30200011502400102600
    2.56602041M369503M30102720
    6001.67702041M3611003M30220011502500102800
    2.57702041M3611003M30102950
    7001.68402441M3613503M30250011503000103000
    2.58752448M4213503M30103200
    8001.69502441M4215004M36270012503000103300
    2.59902448M4215004M36103500
Gas Eliminator Discharge The Gas (LPX)Gas Eliminator Discharge The Gas (LPX)Gas Eliminator Discharge The Gas (LPX)