China 500lph Brackish Water System / High Salty Underground Water Treatment Plant for Irrigation / Drinking, Find details about China Water Distillation Equipment, Water Treatment Plant from 500lph Brackish Water System / High Salty Underground Water Treatment Plant for Irrigation / Drinking
500LPH Brackish Water System / High Salty Underground Water Treatment Plant For Irrigation / Drinking
kyro-500lph RO Water Purifier Machine: |
1. Capacity: 5000L/H |
2. Rated power: 2.5KW/H |
3. Voltage: 110V/220V/380V, 50Hz/60Hz, single phase/3phase |
4. Desalting rate:>=97% |
5. Water recovery rate: 40% |
6. TDS of raw water: ≤20000μs |
7. TDS of pure water: ≤600μs |
1. Pretreatment system:
(1) Raw water pump CHL2-30 SUS-316 |
(2) Sand filter Φ250 × 1450 with 100KG sand / FRP tank |
(3) Carbon filter Φ250 × 1450 with 25KG carbon / FRP tank |
(4) Chemical dosing pump and tank |
(5) Cartridge filter 20″×5μm 2core |
2. RO system parts:
(1) High pressure pump: China Nanfang CNP brand |
(2) Ro membrane: USA Dow brand |
(3) RO membrane housing FRP |
(4) Ro rack and other related meters |
Raw water→ raw water pump→quartz sand filter →activated carbon filter→chemical dosing system→security filter→high pressure pump→ro system→water supply point
Brackish water from the water pump into the quartz sand (multi-media filter) and activated carbon filtration system filtration. Filtered water after water quality reduction, PH adjustment and scale inhibitor added after the access to the precision and security filtration system, filtered low pressure brackish water all the way into the high-pressure pump pressure, the other way into the pressure exchange energy recovery device, after pressurized pump pressurized with high pressure pump into the reverse osmosis membrane reactor system. High-pressure brackish water in the membrane reactor under the treatment of the formation of fresh water through the membrane after water quality adjustment into the fresh water tank storage. The rest of the high pressure concentrated water enters the pressure exchange energy recovery unit to recover the energy after discharge.