Sjr2-3000 Series Inbuilt Bypass Soft Starter

China Sjr2-3000 Series Inbuilt Bypass Soft Starter, Find details about China Soft Starter, Built in Bypaas Soft Starter from Sjr2-3000 Series Inbuilt Bypass Soft Starter

Model NO.
SJR2-3000
Condition
New
Customized
Non-Customized
Material
Aluminum Alloy
Color
Grey
Trademark
SANYU
Transport Package
Carton, Wooden Box
Specification
CE, CCC, SGS, ISO.
Origin
China
HS Code
85114099
Model NO.
SJR2-3000
Condition
New
Customized
Non-Customized
Material
Aluminum Alloy
Color
Grey
Trademark
SANYU
Transport Package
Carton, Wooden Box
Specification
CE, CCC, SGS, ISO.
Origin
China
HS Code
85114099
SJR2-3000 Series soft starter with inbuilt bypass contactor the soft starter provides complete motor protection functions including start control, running and overloading, phase failure, three-phase unbalance, over-voltage, under-voltage protection and so on with no need to further install bypass contactor and thermal relay, therefore, as another great achievement in the intelligentization of motor protection and networked technology application, it simplifies the circuit, reduces the volume, cuts the cost, makes installation and using more convenient.

Power supply: Three-phase AC 380V or 660V± 15%, 50 Hz or 60 Hz commercial power, private power station or diesel generator set, the power capacity must meet the soft starter's starting requirements on motor.
Applicable motor: Three phase squirrel-cage asynchronous motor, the rated power of the motor should match that of the soft starter.
Start frequency: No requirements, the specific frequency shall be depended on the loading.


Sjr2-3000 Series Inbuilt Bypass Soft Starter
 

Classification

Terminal marking

Terminal description

Function description

Connection point output

01, 02

Power input

01, 02 are AC220V power input to the control panel

03, 04

Running output (delay)

03, 04 are programmable relay output, the delay time is set by the code F4 while the output function time is set by code FE.

05, 06

Fault output

005, 06 are fault relay output, they will be on when there's fault with the soft starter or the power is cut off and be off when the power is on. (capacity of the connection point AC250V/3A)

Connection point input

07

Instantaneous stop input

The motor will stop immediately when 07 and 10 are disconnected (or be tandemly connected to the normally closed point of the thermal relay)

08

Soft stop input

The motor will slow down for soft stop when 08 and 10 are disconnected (or automatically stop).

09

Start input

The motor will start for running when 09 and 10 are connected.

10

Common terminal

Common terminal for signal input of the connection points

Analog output

11, 12

Analog output

11 and 12 are 4~20Ma DC analog output which are used to monitor the current of the motor in real time. The maximum value 20mA indicates the current of the motor is four times of the nominal current of the soft starter.4~20Ma DC meter can be connected for observation. Maximum load resistance of this output is 300Ω.

Communication

DB

RS485communication input/output

Input and output signal terminal of RS485 communication, can be used to connect several soft starters.

Sjr2-3000 Series Inbuilt Bypass Soft StarterSjr2-3000 Series Inbuilt Bypass Soft StarterSjr2-3000 Series Inbuilt Bypass Soft StarterSjr2-3000 Series Inbuilt Bypass Soft Starter