70sqmm95sqmm 120mm2 240mm2 300mm2 630mm2 XLPE Single Core Power Cable

China 70sqmm95sqmm 120mm2 240mm2 300mm2 630mm2 XLPE Single Core Power Cable, Find details about China 70sqmm Cable, 95sqmm Cable from 70sqmm95sqmm 120mm2 240mm2 300mm2 630mm2 XLPE Single Core Power Cable

Model NO.
70sqmm 95sqmm 120mm2 240mm2 300mm2 400mm2 Cable
Wire Core Material
Copper
Certification
ISO, CCC, CE, RoHS
Model
YJV
Brand
Hongda
Armour
Unarmour
Conductor Material
Copper
Standard
IEC
Quality Guarantee
Ten Years
Core
1 Core
Insulated Color
Red
Sheath Color
Black
Sample
Yes
Manufacture
Yes
Trademark
Hongda
Transport Package
Wooden Drum
Specification
0.6/1KV Copper power cable
Origin
China, Henan
HS Code
8544492100
Model NO.
70sqmm 95sqmm 120mm2 240mm2 300mm2 400mm2 Cable
Wire Core Material
Copper
Certification
ISO, CCC, CE, RoHS
Model
YJV
Brand
Hongda
Armour
Unarmour
Conductor Material
Copper
Standard
IEC
Quality Guarantee
Ten Years
Core
1 Core
Insulated Color
Red
Sheath Color
Black
Sample
Yes
Manufacture
Yes
Trademark
Hongda
Transport Package
Wooden Drum
Specification
0.6/1KV Copper power cable
Origin
China, Henan
HS Code
8544492100
 70sqmm 95sqmm 120mm2 240mm2 300mm2 630m2 XLPE Single Core Power Cable

70sqmm95sqmm 120mm2 240mm2 300mm2 630mm2 XLPE Single Core Power Cable

70sqmm95sqmm 120mm2 240mm2 300mm2 630mm2 XLPE Single Core Power Cable

1. Product Application.

     PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.
     XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.

2. Standard.

GB/12706-2008, IEC60502-1,IEC 60228,IEC60332 BS 5467,IS 1554 , IS 7098 ect.
we can also design and produce for special application requirement.

3. Operating Characteristics.

3.1 U0/U(Um) Rated Voltage of Cable

,0.6/1(1.2) No. of cores : 1 , 2 , 3, 4 , 5, 3+1 , 4+1 ,3+2 Nominal cross-section(mm2): 1.5~630
0.6/1(1.2), 1.8/3(3.6) 3.6/6(7.2), 6/6(7.2)-6/10 (12) 8.7/10(12) 8.7/15(17.5) 12/20(24) 18/30(36) 21/35(40.5) 26/35(40.5) kV
3.2 The rated Temperature of Conductor
a) The long-time operating temperature of conductor should not be higher than 90ºC
b) If the core is in short circuit, short circuit temperature of conductor should not exceed 160ºCnot more than 5sec.
3.3 Ambient Temperature
When installation, the ambient temperature should not be lower than 0ºC, otherwise the cable need be preheated.
3.4 Bending Radius
Bending radius of single core cable is 20(d+D) ±5%
Bending radius of multi-core cable is 15(d+D) ±5%
d: Actual diameter of the conductor (mm)
D: Actual outer diameter of cable sample (mm)

4. Specification of product.

1). Rated Voltage, No. of Core and Range of Sectional Area
Rated voltage (kv)
Sectional area (mm2)
No. of core
1st class0.6/11.8/33.6/66/108.7/1512/2018/3021/35
2nd class1/13/36/68.7/1012/1518/20-26/35
1 Core 1.5-80025-80025-120025-120035-120050-120050-120050-1200
2 Core 1.5-18525-185      
3 Core 1.5-40025-40025-40025-40035-40050-40050-40050-400
4 Core 2.5-40025-400      
5 Core 2.5-40025-400      

 2). DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.
Nominal section area (mm2)1.52.54610162535507095120150185240300400500630800
Copper core12.17.414.613.081.831.150.7270.5240.3870.2680.1930.1530.1240.0990.07540.06010.0470.03660.02830.0221
Aluminum core18.112.17.414.613.081.911.20.8680.6410.4430.320.2530.2060.1640.1250.10.7780.06050.04690.0367

 3). Voltage Test and Partial Discharge Test
Rate voltage Uo (kv)
Item
0.6/11.8/33.6/66/6 6/108.7/10 8.7/1512/2018/20 18/3021/3526/35
VoltageTest voltage3.56.512.52130.5426373.591
Test time555555555
Partial discharge testTest voltage--6.210.415.120.831.136.345
Discharge capacity--10101010101010
 

5. Construction.

Conductor shaped:RE=circular solid,CC=compacted circular stranded,SM=sector shaped stranded
Conductors: Plain circular, compacted or shaped stranded copper or aluminium conductor
Insulation: XLPE (cross-linked polyethylene) rated at 90°C
Colour identification
1 Core : Red or Black
2 Cores : Red, Black
3 Cores: Red, Yellow, Blue
4 Cores: Red, Yellow, Blue, Black
5 Cores: Red, Yellow, Blue, Black, Green
Above 5 Cores: Black Cores with White numerals
The above identifying can be changed as order
Assembly /Inner Sheath :Two, Three or Four insulated conductors are laid-up together with non-hygroscopic fillers and the assembly is bedded with an extruded layer of PVC. In case of non-armoured cables, this layer may be omitted
Armour:Aluminum/Galvanized Steel Wires, single core cables shall be Aluminium wire armour, Aluminum/Steel Tapes applied helically over the bedding of multi-core cables as per IEC 60502.
Outer Sheath:Outer sheath shall be of Extruded PVC Type ST2 as per IEC 60502-1 or Type 9 as BS 6346/5467.Special type of PVC sheathing material such as Fire Retardant PVC, Anti-Termite PVC, Anti-Rodent PVC, Sunlight resistant PVC, Oil Resistant PVC are available on special request. Also, special sheathing materials such as LLDPE, MDPE, HDPE, LSZH, and CPE are available on request.

ItemDESCRIPTIONUNITTENDERED
1TYPE: CU/XLPE/PE 1x120mm2
a) Manufacturer's nameNameZHENGZHOU HONGDA CABLE CO., LTD
b) Country of originNameChina
c) Rated voltageKV0.6/1
2Applies Standard ·IEC60502
3Conductor:  
a) Material-Plain annealed soft copper
b) Normal section areamm²120
c) Conductor shape-Stranded compacted circular (Class 2)
d) Number of coreeach1
e) Number and diameter of individual wire       No./mm24/2.52
fConductor diametermm13
4
 
Insulation:  
a) Material-XLPE
b) Color-Natural
c) Nominal Thicknessmm1.2
5Out Sheath:  
a) Material PE
b) Color Black
c) Nominal Thickness 1.5
6Approx. weight of cablekg/km1175
7Approx. Diameter of cablemm18.4
8Permitted temperature on core:  
a) Long-term working temperatureºC-15~90
b) Max. temperature in short circuit   ºC250
9MaxDC. Conductor resistance at 20ºCohm/km0.153



1. 1 core: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2, 500mm2, 630mm2.
 
2. 2 core: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2.
 
3. 3 core: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2.
 
4. 4 core: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2.
 
5. 5 core: 1.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2, 50mm2, 70mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2, 300mm2, 400mm2.
 
6. 3+1 core: 2.5+1.5mm2, 4+2.5mm2, 6+4mm2, 10+6mm2, 16+10mm2, 25+16mm2, 35+16mm2, 50+25mm2, 70+35mm2, 95+50mm2, 120+70mm2, 150+70mm2, 185+95mm2, 240+120mm2, 300+150mm2, 400+185mm2
 
7. 3+2 core: 2.5+1.5mm2, 4+2.5mm2, 6+4mm2, 10+6mm2, 16+10mm2, 25+16mm2, 35+16mm2, 50+25mm2, 70+35mm2, 95+50mm2, 120+70mm2, 150+70mm2, 185+95mm2, 240+120mm2, 300+150mm2, 400+185mm2
 
8. 4+1 core: 2.5+1.5mm2, 4+2.5mm2, 6+4mm2, 10+6mm2, 16+10mm2, 25+16mm2, 35+16mm2, 50+25mm2, 70+35mm2, 95+50mm2, 120+70mm2, 150+70mm2, 185+95mm2, 240+120mm2, 300+150mm2, 400+185mm2

6. Packaging&Delivery.
70sqmm95sqmm 120mm2 240mm2 300mm2 630mm2 XLPE Single Core Power Cable   70sqmm95sqmm 120mm2 240mm2 300mm2 630mm2 XLPE Single Core Power Cable

Packaging Details:
Wooden drums,steel wooden drums or as your requirement
Delivery Time:Normally within 7 days(detailly depend on the order quantity)

7. Contact us
Looking forward to cooperation with you.If you have any question or need our certification and sample.Pls contact me freely.You can talk with me by Email or chat software.

Telphone: +86 15039132763