China Apply for Pig Offals Collection and Other Processing Slaughtering Equipment, Find details about China Slaughtering Equipment, Offal Collection from Apply for Pig Offals Collection and Other Processing Slaughtering Equipment
Fault phenomenon | Possible cause | Overhaul method |
Do not work after turning on the power supply, no indication of work indicator | 1.The power supply is not on or in bad contact 2.The circuit breaker in the control box is not closed 3.Fuse damage of controller | 1. Connect the power supply, deal with the bad part 2. Close the circuit breaker 3. Find the cause, replace the mental fuse. |
No automatic operation | 1.The automatic working switch is not on or out of order 2.Sensor lines or not well connected. Sensor adjusting 3.distance is too close | 1.Overhaul or replace automatic switch 2. Reconnect line 3. according to wiring diagram. Readjusting the effective distance of the sensor |