China Cheapest Smart Meter Me238 3 Phase Remote WiFi Ampere Meter 333mv CT Electronic Meter, Find details about China Power Analysis Energy Meter RS485 Modbus RTU, Universal Handheld Digital Multimeter RS485 from Cheapest Smart Meter Me238 3 Phase Remote WiFi Ampere Meter 333mv CT Electronic Meter
Description | |||||
Type | 96*96 Panel Meter | ||||
Poles description | 3PH3W ,3PH4W. | ||||
Application | Current,Voltage,Power,Energy and harmonic measurement | ||||
display screen | 3.8 inch LCD segment code display screen. | ||||
Weight | 259g | ||||
Dimension | L*W*D:8.1*8.1*3CM | ||||
Color | White and black | ||||
Model | ME238 | ||||
Current sensor type | 333mV CT and Rogowski coil | ||||
Advantage | 3 IN 1 current sensor with RJ45 port easy to install | ||||
Current | |||||
Model | ME238 | ||||
Primary Rated current | 5A | 100A | 600A | 2500A | 6000A |
Secondary Rated input | 333mV | 50mV/kA@50Hz | 85mV/kA@50Hz | 50mV/kA@50Hz | |
Input channel maximum value | 500mV | ||||
Current measurement Range | 0.005~5A | 0.5A to 100A | 2A to 600A | 2.5A to 2500A | 6A to 6000A |
Recommended Sensor model | STP-5 | STP-100 or STP-100R | STP-600 | STP-2.5K | STP-6K |
STP-5 | 3 IN 1 RJ45 Split core CTs (O.D.10mm) |
STP-100 | 3 IN 1 RJ45 Split core CTs (O.D.16mm) |
STP-100R (Choice STP-100R when STP-100 can't not be easy to install) | 3 IN 1 RJ45 Rogowski Coil +Integrator (O.D.24mm) | |
STP-600 | 3 IN 1 RJ45 Rogowski Coil (O.D.36mm) | |
STP-2.5K | 3 IN 1 RJ45 Rogowski Coil (O.D.150mm) | |
STP-6K | 3 IN 1 RJ45 Rogowski Coil (O.D.200mm) | |
Voltage | ||
Range | 0~600VAC Phase to Phase Voltage | |
Maximum range | 720VAC Phase to Phase Voltage | |
Digital Signal | ||
Energy pulse output | Active energy pulse output, optocoupler isolation (5kvrms) | |
Relay output | One way electromagnetic relay output, including normally open and normally closed contacts, contact capacity: 3A 30V DC, 3A 250V AC | |
Digital input | 2-way dry contact input, optocoupler isolation (5kvrms) | |
Communication | ||
RS485 communication | One way RS485 communication interface Interface type: two wire half duplex Communication baudrate: 2400bps ~ 19200bps Protocol: Modbus RTU | |
Power supply | ||
Power Supply | 95~265VAC/110~260VDC, 45~60Hz | |
Maximum power consumption | 3.5VA |
Measuring data | |
Phase Voltage | U1, U2, U3 and average value. |
Line Voltage | U12, U23, U31 and average value. |
Current | I1, I2, I3 and average value. |
Power | Active power,Reactive power,Apparent power (total and per phase). |
Energy | Active energy import,active energy export, reactive energy import, reactive energy export.apparent energy. If it exceeds 9999999.9kwh, the energy value will be reset to "0" automatically. |
Harmonic | The total harmonics of each phase of voltage and current. |
Power Factor | Including power factor PF and fundamental power factor DPF (average value of each phase and three phases) |
Grid Frequency | Synthetic frequency |
Update rate | |
Data refresh rate | 500ms |
Harmonic | |
Voltage | Total harmonic phase |
Current | Total harmonic phase |
Max / min | |
Voltage | Per phase |
Current | Per phase |
Power | Active power,Reactive power,Apparent power (sum of all phases and three phases) |
Unbalance degree | |
Voltage | Per phase |
Current | Per phase |
Demand / maximum demand | |
Current | Per phase |
Power | Active power, Reactive power, Apparent power (sum of all phases and three phases) |
Measuring accuracy | |
Model | ME238 |
Current measurement | ±0.5%RDG |
Guarantee range of current measurement accuracy | 1% FS~100%FS |
Voltage measurement accuracy | 0.2%(30~600V AC) |
Grid frequency | 0.01%(45~65Hz) |
Power factor | ±0.005 |
Active and apparent power | IEC62053-22 level 0.5S |
Reactive power | IEC62053-21 level 2S |
Active energy | IEC62053-22 level 0.5S |
Reactive energy | IEC62053-21 level 2S |
Environment condition | |
Operating temperature | -25ºC~+60ºC |
Storage temperature | -40ºC~+85ºC |
Humidity range | 5~95% RH, 50ºC(non-condensing) |
Class of pollution | 2 |
Over voltage capability | CAT III 1000V, It is suitable for distribution system below 277 / 480VAC |
Insulation strength | IEC61010-1 |
Altitude | 3000m Max |
Antipollution level | IP20(Meet the standard of IEC 60629) |
Quality guarantee period | 12 months |
EMC(electromagnetic compatibility) | |
Electrostatic discharge | Level CAT IV 600V (IEC61000-4-2) |
Radiated immunity | Level CAT III 1000V (IEC61000-4-3) |
EFT Electrical fast burst immunity | Level CAT IV 600V (IEC61000-4-4) |
Surge immunity | Level CAT IV 600V (IEC61000-4-5) |
Conducted disturbance immunity | Level CAT III 1000V (IEC61000-4-6) |
Power frequency magnetic field immunity | 0.5mT (IEC61000-4-8) |
Conduction and radiation | Class B (EN55022 ) |
Measurement standard | |
EN 62052-11, EN61557-12, EN 62053-21, EN 62053-22, EN 62053-23, EN 50470-1, EN 50470-3, EN 61010-1, EN 61010-2, EN 61010-031 |