Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor

China Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor, Find details about China Pressure Transmitter, Pressure Transducer from Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor

Model NO.
HPM710
Thread Type
G
Wiring Type
Two-Wire
Measuring Medium
Liquid Gas
IP Rating
IP65
Certification
ISO9001
Customized
Customized
Sensor Type
Pressure Sensor
Pressure
-100kPa...0~20kPa...10MPa
Housing Material
316L
Accuracy
0.5%F.S.
Over Pressure
1.5 times the full scale
Supply
24VDC
Output
4-20mADC or 0-5V, 0-10V, 1-5V
Working Temp
-20~85ºC
Medium Temperature
-40~85ºC or -40~150ºC
Protection of Shell
IP65
Electrical Connection
DIN43650
Trademark
HangJia Sensor
Transport Package
Carton
Origin
China
HS Code
90262010
Model NO.
HPM710
Thread Type
G
Wiring Type
Two-Wire
Measuring Medium
Liquid Gas
IP Rating
IP65
Certification
ISO9001
Customized
Customized
Sensor Type
Pressure Sensor
Pressure
-100kPa...0~20kPa...10MPa
Housing Material
316L
Accuracy
0.5%F.S.
Over Pressure
1.5 times the full scale
Supply
24VDC
Output
4-20mADC or 0-5V, 0-10V, 1-5V
Working Temp
-20~85ºC
Medium Temperature
-40~85ºC or -40~150ºC
Protection of Shell
IP65
Electrical Connection
DIN43650
Trademark
HangJia Sensor
Transport Package
Carton
Origin
China
HS Code
90262010
Product Overview:

HPM710 Flat Film Hygienic Pressure Transmitter adopts flat film which can directly receive the pressure signal and adopts the silicon pressure core as sensitive element and the standard silicon oil or olive oil as pressure transmission medium. The measuring terminal of product uses 316L stainless steel with compact structure, corrosion resistance, vibration resistance and wide range of temperature compensation. Because the exposed stress diaphragm at the end of thread can directly receive the pressure, it can solve the problems like scale formation, insanitation and blocking of viscous pressure, especially suitable for the measurement of viscous fluid and liquid level with hygienic requirements in the fields of medicine and food.


Features:

·Pressure interface adopts 316L flat film structure
·Hygienic type, scale formation resistance
·Short-circuit protection and reverse polarity protection
·With cooling fin design optional, excellent application performance for high temperature mediums
·Optional various output signal , can be customized according to requirements


Parameters:
 
Measuring MediumLiquid, Gas
Pressure Range-100kPa...0~20kPa...10MPa
Overload1.5 times the full scale
Pressure TypeGauge, Absolute or Sealed Gauge
Accuracy±0.5%FS
Long-term Stability±0.25%FS/year
Temperature Coefficient of Zero±0.5%FS/ºC
Temperature Coefficient of Full Scale±0.5%FS/ºC
Working Temp-20~85ºC
Storage Temp-40~85ºC or -40~150ºC
Supply Voltage24VDC
Output Signal4~20mADC, 0~5VDC, 1-5VDC, 0~10VDC
Insulation Resistance100MΩ,500VDC
Protection of ShellIP65
Electrical ConnectionHirschman DIN43650
Housing Material316L


Structure Drawings:


Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor

Pressure Port:
 
M20×1.5G1/2
Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor
 
Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor
 
G1High Temperature
Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor
 
Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor
 



Electrical Connection:

Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor
Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor

Ordering Guide:
 
Item NO.Type 
HPM710Flat Film Hygienic Pressure Transmitter
 Pressure RangeMeasuring Range 
(0~X)kPaFill out X directly
 CodeOutput Signal 
B1(4~20)mA
B3(0~10)V
B4(0~5)V
B5(1~5)V
 CodeThread Spec 
P2M20×1.5 Top Sealed
P4G1/2 Top Sealed
P19G1 Top Sealed
 CodeElectrical Connection 
C1DIN43650
C2Cable Outlet
C3Aviation Connector
 CodeStructure&Material
M2316L
 CodeAdditional Functions
Y22088 Shell
Y5Delicate Protecting Jacket
THigh-temperature Resistance
HPM710(0~40)kPaB1P1C1M2Y5


Related Products:

Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor



Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor

Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor
Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor

Certification:
Diffused Silicon Flush Diaphragm Hygienic Pressure Sensor



FAQ:

1.    Q: Are you manufacturer or trading company?
        A: We are manufacturer which focuses on sensor for 10 years.

2.    Q: What's your quality control system?
        A: MC, ISO9001, CE Certificated.

3.    Q: What is the warranty of your products?
        A: Our warranty time is 18 months after shipment.
 
4.     Q: What is lead time of your product?
         A: Normally, our factory lead time is within 10~15 working days for products without customization. You can also check lead time detail with our sales depending on different items.
 
5.     Q: Do you provide customized products?
         A: Yes, we can laser mark your logo on products; OEM and ODM customization are welcomed.
 
6.     Q: What is your MOQ?
        A: We have no MOQ limit, small quantity order is acceptable.
 
7.      Q: What's the transport?                                                              
        A: Express such as DHL, FedEx, TNT, UPS for freight prepaid; and we can also use your own courier account to do the freight collect. For more goods we can arrange by air or by Sea.
 
8.      Q: What is your terms of payment ?
           
A: We could accept T/T, Paypal, WU.