Portable Patient Monitor Bw3b , ECG NIBP, SpO2, Temperature, Pulse Rate

China Portable Patient Monitor Bw3b, ECG NIBP, SpO2, Temperature, Pulse Rate, Find details about China Multiparameter Patient Monitioring, Patient Monitoring System from Portable Patient Monitor Bw3b, ECG NIBP, SpO2, Temperature, Pulse Rate

Model NO.
BW3B
Trademark
BONDWAY
Origin
China
HS Code
9018193000
Model NO.
BW3B
Trademark
BONDWAY
Origin
China
HS Code
9018193000
Multiparameter Patient Monitor (Patient monitoring system)
Model No: BW3B
TFT LCD size: 12.1-inch


This multiparameter patient monitor, designed with 12.1-inch TFT LCD display, standard parameters including ECG, SPO2, NIBP (non-invasive blood pressure), Temperature, Pulse Rate, Optional including EtCO2, IBP (invasive blood pressure) and built-in recorder (printer)
Portable Patient Monitor Bw3b, ECG NIBP, SpO2, Temperature, Pulse Rate
Features:
1) Attractive streamline outline design, portable, compact and lightweight
2) 12.1" color TFT LCD display
3) Operation menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, French, German
4) Big Font Display
5) ST segment Analysis and Apnea Alarm function
6) Drug Dose Calculation and OXCRG Software
7) 72-hour tabular and graphic trends and data storage
8) High energy Li-ion battery for short-term transport and temporary power-down
9) Networking Capability. WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
10) Linux Operation System
11) External display(VGA interface) and external printer connectible to record tabular and graphic trend
12) Dynamic Monitoring of blood pressure
13) Intelligent audio and visual alarm
14) Application: Adult, Pediatric and Neonate
15) Pacemaker detection and Arrhythmia Analysis( Optional)
Portable Patient Monitor Bw3b, ECG NIBP, SpO2, Temperature, Pulse Rate

Technical Specs
ECG

Input: 5 lead ECG cable
Lead section: Lead I, II, III/ aVR, aVL, aVF/ V
Gain(mm/mV): 1/4, 1/2, 1, 2, 4
Frequency response: Diagnosis 0.05 - 100Hz
Monitor mode 0.5 - 40 Hz
Surgery 1.0 - 25 Hz
Sweep speed (mm/sec): 12.5, 25, 50
Heart rate range: 20-254 BPM
ST segment deviation analysis: -0.8-+0.8mV
Protection: Against electrosurgical interference and defibrillation

NIBP
Method: Automatic Oscillometric
Measurement range: Systolic 4.0 - 37.0 kPa
Diastolic 1.3 - 33.0 kPa
Mean 2.6 - 35.0 kPa
Scale: MmHg/Kpa
Operating Mode: Manual/Auto/STAT
Over pressure Protection: Yes

SpO2
Measurement range: 0 - 100 %
Pulse Rate range: 30- 254BPM
Accuracy: ± 2 %
Probe: For Neonate, pediatric, and adult

2-Temperature
Channel: Two Channels
Measurement range: 29- 45Celsius temperature
Accuracy: ± 0.1Celsius temperature
Scale: Celsius/Fahrenheit
Portable Patient Monitor Bw3b, ECG NIBP, SpO2, Temperature, Pulse Rate
RESP. rate
Method: Impedance
Measurement range: 0 - 120 BPM
Lead Connection: RA & LL or RA & RA

Power requirements
Input: 98~260 V AC, 50/60Hz
Consumption: ≤ 80VA
Safety standards: GB9706.1 IEC 60601-1 UL 544

EtCO2( Optional)
Method: Side Stream
Measurement range: 0 % - 10.0 % in CO2 and et CO2)
Display: Waveform, Respiration Rate, EtCO2, FiCO2
Scale: MmHg/Kpa

2-IBP ( Optional)
Channel: 2 Channels
Parameter: SYS/DIA/MAP/Pulse Rate
Scale: MmHg/kPa

Built-inRecorder (Optional)
Type: Built-in Thermal Recorder
Print Mode: Waveform and/or Text
Portable Patient Monitor Bw3b, ECG NIBP, SpO2, Temperature, Pulse Rate