Hm-2000d Medical Multi-PARA. Patient Monitor

China Hm-2000d Medical Multi-PARA. Patient Monitor, Find details about China Patient Monitor, Monitor from Hm-2000d Medical Multi-PARA. Patient Monitor

Model NO.
HM-2000D
Charging Time
2 Hours
Standard Parameters
ECG,Resp,NIBP,SpO2,Pr/Hr,Temp
Warranty
12 Months
Output
DC 12V-20V
Operating Time
3.5-4 Hours Working Time Under Ful
Input
AC 90 V~240V, 50/60Hz
Trademark
Healicom
Transport Package
Carton
Origin
China
HS Code
9018909090
Model NO.
HM-2000D
Charging Time
2 Hours
Standard Parameters
ECG,Resp,NIBP,SpO2,Pr/Hr,Temp
Warranty
12 Months
Output
DC 12V-20V
Operating Time
3.5-4 Hours Working Time Under Ful
Input
AC 90 V~240V, 50/60Hz
Trademark
Healicom
Transport Package
Carton
Origin
China
HS Code
9018909090

HM-2000D Medical Multi-PARA. Patient Monitor

Hm-2000d Medical Multi-PARA. Patient Monitor


Specification

Standard parameters:ECG,RESP,NIBP,SPO2,PR/HR,TEMP.
13 types Arrhythmic Analysis, Multi-lead ECG waveforms display in Phase, 15 types Drug calculation and titration table.
Anti-ESU, anti-defibrillator; RA-LL impedance.
SPO2 can testing for 0.1% weak,high accuracy.
Unique breathing measurement technology, real-time monitoring, intelligent filter design, eliminate interference, measuring respiratory accurately.
Trend Coexist interface for all parameter to observe easily.
OxyCRG Dynamic View display, More intultive with all parameters.
Platform scalable with cable or wireless connecting to central monitoring.
Printer /Recorder is optional for real-time printing.
Brief operation interface, Touchscreen is optional.Up to 2-5 hours working capacity of built-in rechargeable Li-ion battery.
12.1"high resolution color TFT LCD display.
Holographic waveform trends playback for 2 weeks and 12 hours off electricity saving.
Built-in networking to realize central monitoring function.
Optional: Touchscreen, VGA, 2-IBP, HDMI, ETCO2.
System start up only need 10 seconds with ARM-A5 Nuclear technology.


Standard accessory

5-lead ECG cable1pc
Surface temp.probe    1pc
Adult NIBP cuff  1pc
NIBP tube    1pc
Adult SpO2 sensor1pc
Power cord            1pc
Electrode          5pcs
User manual   1pc
 

Specifications

1. ECG
Lead Mode5 Leads or 3 Leads
3 LeadsRA,LA,LL,Lead mode:I,II,III
5 LeadsRA,LA,LL,RL,V,Lead mode:I,II,III,aVR,aVL,aVF,V
Gain  ´250,´500,´1000,´2000
Heart Rate :
RangeAdult:15 ~ 300bpm ; Neonate / Pediatric:15 ~350 bpm
Accuracy±1%or ±1bpm
Resolution1 bpm
Sensitivity>200 uV
Differential Input Impedance>5MΩ
Bandwidth
Diagnostic0.05~130Hz
Monitor0.5~40Hz
Surgery1~20Hz
2. RESP
MethodImpedance between R-F(RA-LL)
Scope of base impedance200~4000Ω
Bandwidth0.1~ 2.5 Hz
RESP
RangeAdult:2~120BrPM   Neonate / Pediatric :2~150 BrPM
Resolution1 BrPM
Accuracy±2 BrPM
Suffocation warning10~40s
3. NIBP
MethodOscillometric
ModeManual, Auto, STAT
Measuring interval in AUTO MODE1,2,3,4,5,10,15,30,60,90,120,180,240,480 MINS
Measuring interval in STAT MODE5 MINS
PR range40~240 bpm
Measuring Range and Resolution
AdultSYS          40~270mmHg
DIA          10~215mmHg
MEAN       20~235mmHg
PEDSYS          40~200mmHg
DIA          10~150mmHg
MEAN        20~165mmHg
NEOSYS          40~135mmHg
DIA          10~100mmHg
MEAN        20~110mmHg
STATIC NIBP range0~300mmHg
Static NIBP accuracy±3mmHg
Max Average tolerance±5mmHg
Max. Standard tolerance8mmHg
Over-pressure protection:
Adult mode300 mmHg
Ped mode240 mmHg
Neo mode150 mmHg
4. SpO2
Measuring range0~100%
Resolution1%
Accuracy70~100%:±2;0%~69%
Pulse Rate:
Measuring range20~300bpm
Resolution1bpm
Accuracy±3bpm
5. TEMP
Channels2
Measuring:
Range0~50°C
Resolution0.1°C
Accuracy±0.1°C(sensor tolerance no not included )
6. Power
Adapter:
InputAC 90 V~240V, 50/60Hz
OutputDC 12V-20V
Built-in Battery:
TYPE14.8V, 2200mAH Li-ion rechargeable battery
Operating time3.5-4 hours working time under full power
Charging time2 hours
7. IBP(Optional)
Label  ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART0 ~ 300 mmHg
PA -6 ~ 120 mmHg
CVP/RAP/LAP/ICP-10 ~ 40 mmHg
P1/P2-10 ~ 300 mmHg
Press Sensor
Sensitivity 5  uV/V/mmHg
Impedance 300-3000Ω
Resolution     1 mmHg
Accuracy±2% or ±1mmHg, which great
Actualization intervalabout 1 Sec
8. CO2(Optional)

Measuring and alarm range 

0% ~ 13%
Resolution   1 mmHg
Accuracy2 mmHg @ < 5.0% co2 (at ATPS)
RR  3 - 150 bpm
 

Customer Testing

Hm-2000d Medical Multi-PARA. Patient Monitor
 

Dteailed Pictures
Hm-2000d Medical Multi-PARA. Patient Monitor
 

Packing&Shipping

Hm-2000d Medical Multi-PARA. Patient Monitor