China Hm-2000d Medical Multi-PARA. Patient Monitor, Find details about China Patient Monitor, Monitor from Hm-2000d Medical Multi-PARA. Patient Monitor
HM-2000D Medical Multi-PARA. Patient Monitor
Specification
Standard parameters:ECG,RESP,NIBP,SPO2,PR/HR,TEMP. |
13 types Arrhythmic Analysis, Multi-lead ECG waveforms display in Phase, 15 types Drug calculation and titration table. |
Anti-ESU, anti-defibrillator; RA-LL impedance. |
SPO2 can testing for 0.1% weak,high accuracy. |
Unique breathing measurement technology, real-time monitoring, intelligent filter design, eliminate interference, measuring respiratory accurately. |
Trend Coexist interface for all parameter to observe easily. |
OxyCRG Dynamic View display, More intultive with all parameters. |
Platform scalable with cable or wireless connecting to central monitoring. |
Printer /Recorder is optional for real-time printing. |
Brief operation interface, Touchscreen is optional.Up to 2-5 hours working capacity of built-in rechargeable Li-ion battery. |
12.1"high resolution color TFT LCD display. |
Holographic waveform trends playback for 2 weeks and 12 hours off electricity saving. |
Built-in networking to realize central monitoring function. |
Optional: Touchscreen, VGA, 2-IBP, HDMI, ETCO2. |
System start up only need 10 seconds with ARM-A5 Nuclear technology. |
Standard accessory
5-lead ECG cable | 1pc |
Surface temp.probe | 1pc |
Adult NIBP cuff | 1pc |
NIBP tube | 1pc |
Adult SpO2 sensor | 1pc |
Power cord | 1pc |
Electrode | 5pcs |
User manual | 1pc |
Specifications
1. ECG | |
Lead Mode | 5 Leads or 3 Leads |
3 Leads | RA,LA,LL,Lead mode:I,II,III |
5 Leads | RA,LA,LL,RL,V,Lead mode:I,II,III,aVR,aVL,aVF,V |
Gain | ´250,´500,´1000,´2000 |
Heart Rate : | |
Range | Adult:15 ~ 300bpm ; Neonate / Pediatric:15 ~350 bpm |
Accuracy | ±1%or ±1bpm |
Resolution | 1 bpm |
Sensitivity | >200 uV |
Differential Input Impedance | >5MΩ |
Bandwidth | |
Diagnostic | 0.05~130Hz |
Monitor | 0.5~40Hz |
Surgery | 1~20Hz |
2. RESP | |
Method | Impedance between R-F(RA-LL) |
Scope of base impedance | 200~4000Ω |
Bandwidth | 0.1~ 2.5 Hz |
RESP | |
Range | Adult:2~120BrPM Neonate / Pediatric :2~150 BrPM |
Resolution | 1 BrPM |
Accuracy | ±2 BrPM |
Suffocation warning | 10~40s |
3. NIBP | |
Method | Oscillometric |
Mode | Manual, Auto, STAT |
Measuring interval in AUTO MODE | 1,2,3,4,5,10,15,30,60,90,120,180,240,480 MINS |
Measuring interval in STAT MODE | 5 MINS |
PR range | 40~240 bpm |
Measuring Range and Resolution | |
Adult | SYS 40~270mmHg |
DIA 10~215mmHg | |
MEAN 20~235mmHg | |
PED | SYS 40~200mmHg |
DIA 10~150mmHg | |
MEAN 20~165mmHg | |
NEO | SYS 40~135mmHg |
DIA 10~100mmHg | |
MEAN 20~110mmHg | |
STATIC NIBP range | 0~300mmHg |
Static NIBP accuracy | ±3mmHg |
Max Average tolerance | ±5mmHg |
Max. Standard tolerance | 8mmHg |
Over-pressure protection: | |
Adult mode | 300 mmHg |
Ped mode | 240 mmHg |
Neo mode | 150 mmHg |
4. SpO2 | |
Measuring range | 0~100% |
Resolution | 1% |
Accuracy | 70~100%:±2;0%~69% |
Pulse Rate: | |
Measuring range | 20~300bpm |
Resolution | 1bpm |
Accuracy | ±3bpm |
5. TEMP | |
Channels | 2 |
Measuring: | |
Range | 0~50°C |
Resolution | 0.1°C |
Accuracy | ±0.1°C(sensor tolerance no not included ) |
6. Power | |
Adapter: | |
Input | AC 90 V~240V, 50/60Hz |
Output | DC 12V-20V |
Built-in Battery: | |
TYPE | 14.8V, 2200mAH Li-ion rechargeable battery |
Operating time | 3.5-4 hours working time under full power |
Charging time | 2 hours |
7. IBP(Optional) | |
Label | ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
Measuring and alarm range | |
ART | 0 ~ 300 mmHg |
PA | -6 ~ 120 mmHg |
CVP/RAP/LAP/ICP | -10 ~ 40 mmHg |
P1/P2 | -10 ~ 300 mmHg |
Press Sensor | |
Sensitivity | 5 uV/V/mmHg |
Impedance | 300-3000Ω |
Resolution | 1 mmHg |
Accuracy | ±2% or ±1mmHg, which great |
Actualization interval | about 1 Sec |
8. CO2(Optional) | |
Measuring and alarm range | 0% ~ 13% |
Resolution | 1 mmHg |
Accuracy | 2 mmHg @ < 5.0% co2 (at ATPS) |
RR | 3 - 150 bpm |