Ready Stock Patient Monitor Most Affordable Bedside Patient Monitor
Parameter:
WHYC80 is designed especially for ICU/CCU/Operation theatre and Trauma care
It is equipped with 12.1" touch screen, handwriting pen, SD card interface,USB interface,
auto dust shield to prevent dust etc foreign matter,wall mount,rolling stand and trolley
multiple mounting options. IPX1 level waterproof cabinet to withstand different rough e
nvironment
Meanwhile,2-channel IBP using the US Abbott/Medex accessories to monitor ABP,
PAP, CVP, ICP et.
EtCO2 collaborate with US RESPIRONICS COMPANY
Anesthesia Gas module collaborate with Sweden ARTEMA to monitor 8 types Gas
including O2, CO2, N2O, ENF, ISO, DES,SEV,HAL
Intelligent Alarm system can auto-identify alarm level, self-adjust proper alarm time to reduce false alarms
Support wire & wireless central monitoring system
Features- Touch-screen for easy operation
- 12.1 inch high resolution color TFT display
- USB interfaces support easy software upgrade and data transfer
- Compatible with Central Monitoring System (CMS)
- Three Working Modes: Monitoring, Surgery and Diagnosis.
- Simple and friendly operating display interface.
- Multi-display modes suitable for different applications:
Standard Interface, Large font, ECG Standard Full Display, OXY , Trend Table, BP Trend.- Built-in high capacity battery up to 3 hours of continuous work
- VGA output for external display
Technique Specification
ECG- Lead Mode: 5 Leads (I, II, III, AVR, AVL,AVF, V)
- Gain: ´2.5mm/mV, ´5.0mm/mV, ´10mm/mV, ´20mm/mV
- Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
Resolution: 1 BPM
Accuracy: ±1%
Sensitivity >200 uV(Peak to peak)- ST measurement range: -2.0 ~ +2.0 mV
Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
Other Range: unspecified- Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
- Bandwidth:
- Diagnostic: 0.05~130 Hz
- Monitor: 0.5~40 Hz
- Surgery: 1~20 Hz
SPO2- Measuring Range: 0 ~ 100 %
- Resolution: 1%
- Accuracy: 70% ~ 100% (±2 %)
- Pulse Rate: 20-250 BPM
- Resolution: 1 BPM
- Accuracy: ±3 BPM
NIBP- Method: Oscillometry
- Measure mode: Manual, Auto, STAT
- Unit: mmHg, kPa
- Measure and alarm range:
- Adult Mode
- SYS 40 ~ 280 mmHg
- DIA 10 ~ 225 mmHg
- MEAN 20 ~ 240 mmHg
- Pediatric Mode
- SYS 40 ~ 220 mmHg
- DIA 10 ~ 160 mmHg
- MEAN 20 ~ 170 mmHg
- Neonatal Mode
- SYS 40 ~ 135 mmHg
- DIA 10 ~ 100 mmHg
- MEAN 20 ~ 110 mmHg
- Resolution: 1mmHg
- Accuracy: ±5mmHg
RESP- Method: Impedance between RA-LL or RALA
- Measurement Range:
Adult: 10 ~ 120 BrPM
Neonatal / Pediatric: 7 ~ 150 BrPM- Resolution: 1 BrPM
- Accuracy: ±2 BrPM
TEMP- Measure and Alarm Range: 0 ~ 50 °C
- Resolution: 0.1°C
- Accuracy: ±0.1°C
Standard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR
Optinal Parameters:- Recorder ( Printer)
- Central monitoring system
- Dual IBP
- Etco2
- 12-lead ECG;
-
- Sun Tech NIBP.
Standard Configuration:No. | Item | Qty |
1 | Main Unit | 1 |
2 | 5-lead ECG cable | 1 |
3 | Disposable ECG Electrode | 5 |
4 | Adult Spo2 probe | 1 |
5 | Adult NIBP cuff | 1 |
6 | NIBP extension tube | 1 |
7 | Temperature probe | 1 |
8 | Power Cable | 1 |
9 | User Manual | 1 |
10 | Fuse | 3 |